Contact Us

UCC28061DR

Brand: Texas Instruments
Texas Instruments UCC28061DR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

UCC28061DR — Power Management & Signal Chain | Superb Automation

UCC28061DR

Texas Instruments — Power Management & Signal Chain

Product Overview

The UCC28061DR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

UCC28061DR: two phase transition mode PFC with natural interleaving and a 6 V reference

The UCC28061DR is a two phase transition mode power factor correction controller. Instead of running one boost stage at twice the current, it runs two out of phase so the input ripple current cancels and the output capacitor sees half the ripple of a single phase stage of the same power. The interleaving is described by the vendor as natural: the second phase starts when the first phase current has fallen to zero, and the controller locks the two phases 180 degrees apart without a fixed clock, so the switching frequency still moves with the line and load in the way a transition mode stage does.

Two features matter to anyone who has fought a PFC stage in a metal enclosure. The first is the improved audible noise immunity, which is the reason the 61 suffix exists over the UCC28060: the phase management logic is filtered so a stage that moves between one phase and two phases at light load does not produce the buzz that a fast phase shed generates. The second is soft start on an output overvoltage event, which pulls the error amplifier output to ground and restarts the loop gently rather than letting the inductor current spike when the load drops suddenly.

Key electrical data for the UCC28061DR

Bias supplyVCC turn on at 12.6 V typical inside a 11.5 V to 13.5 V window, turn off near 10.35 V
ClampInternal VCC shunt at 24 V typical, 22 V to 26 V, which needs a series resistor from a high rail
Reference6.00 V no load output, 5.82 V to 6.18 V window, usable for a small external load
Supply current5 mA to 8 mA enabled, 100 microamps to 200 microamps disabled
SenseVSENSE regulation window 5.85 V to 6.15 V, HVSEN overvoltage at 4.87 V rising and 4.67 V falling
Phase controlPHB pin selects one phase or two, PWMCNTL output flags a phase failure at 2.50 V typical

Package, marking and reel data

BodyD, SOIC 16 pin, 6.00 mm body width, 40 pieces per tube
Reel2500 pieces on a 330 mm reel, 16.0 mm carrier on the taped and reeled row
FinishNIPDAU, moisture level 1 at 260 C with unlimited floor life
SuffixAdding R to the part number gives the reeled body, which is what the catalogue code carries

What the two phases buy on a 300 W stage

The input ripple cancellation is the commercial argument. Two 150 W phases interleaved at 180 degrees reduce the ripple at the input filter by roughly a factor of two at the switching frequency, which lets the differential mode choke and the X capacitor shrink. The output capacitor current is also halved at the same total power, so an electrolytic bank that would have needed 330 microfarads on a single phase stage can be built from smaller cans with a longer life. On a 390 V output the bulk capacitance sets the hold up time, and a smaller bank means a shorter hold up for the same volume, so the trade has to be checked against the load's ride through requirement.

The current sense arrangement matters as much as the phases. Each phase has its own sense resistor and the controller compares each against its own threshold, with the gate outputs held off until the inductor current has decayed to the falling threshold, which the functional description puts near 15 mV. A common mistake is to share one sense resistor between both phases, which defeats the per phase current limit and makes the interleaving unstable. Our power management cross reference page lists the controller and gate driver pairs we supply for this topology.

Buyer questions on the UCC28061DR

Does the controller need an external clock for the two phases? No. The interleaving is derived from the inductor current reaching zero in each phase, so there is no clock pin and no synchronisation to arrange between the two halves.

What happens when the load falls below the phase shed point? The controller drops to one phase and the PWMCNTL output changes state. The 61 version filters that decision so the transition does not produce audible noise from the boost inductor.

Can the 6 V reference power another circuit? It can sink and source a small current, and the vendor shows it biasing circuits that need less than 2 mA. It is not a general purpose rail and should not be loaded beyond that.

Availability and cross reference

Both the tube and the reel are active in the addendum, and the reel is 2500 pieces. Because the part sits in the middle of a PFC stage, the codes that move with it are the gate driver, the sense resistors and the bulk capacitors, and a shortage in any of them stops the build even when the controller is in stock. We keep the controller and the driver on one forecast line for that reason, and the substitution rules are on our how to verify a drop in replacement page.