UCC12050DVER
Product Specifications
UCC12050DVER
Texas Instruments — Power Management & Signal Chain
Product Overview
The UCC12050DVER from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
UCC12050DVER: a 500 mW isolated bias module that takes a 5 V rail on the primary side and delivers one of four regulated outputs across a 5 kVRMS reinforced barrier from a single sixteen pin body
UCC12050DVER is an isolated DC/DC supply built from a driver, an on-chip transformer and a rectifier inside one moulding, with the output voltage chosen by a single pin and the whole barrier certified as reinforced insulation in a SO-MOD body of 16 pins. The DVE body is sixteen pins on a 10.30 mm by 7.50 mm footprint with more than 8 mm of creepage across the barrier, and the part exists because a discrete flyback bias supply cannot hold that creepage and that certification inside the same area.
Order code and package
| Catalogue string | UCC12050DVER, where DVE is the sixteen pin SO module and R is the 2000 piece large reel |
| Body | SO-MOD, DVE, sixteen pins, 10.30 mm by 7.50 mm, with the isolation barrier running across the middle of the package |
| Reel | 2000 pieces on a large tape and reel, the same count on the plain row, the .A row and both G4 rows |
| Tube | the same die also ships 40 pieces in a tube as UCC12050DVE |
| Finish and moisture | NIPDAU plating, moisture level 3 at 260 C with 168 hours of floor life, so an opened bag has to be resealed or the parts baked |
| Temperature | minus 40 to 125 C, printed as an operating range on every row rather than as a junction limit |
| Marking | UCC12050 on the body, with nothing on the top mark to tell the output setting apart |
| Document | SNVSB38D, September 2019, revised February 2021 |
| Status | Active and in production on the addendum dated 7 October 2026 |
Electrical parameters that decide the application
| Input range | 4.5 V to 5.5 V, so a 5 V rail with five per cent tolerance fits and a 3.3 V rail does not, which rules the part out of the low voltage half of a system |
| Output settings | 5.0 V with SEL shorted to VISO at 100 mA, 5.4 V with 100 kOhm from SEL to VISO at 90 mA, 3.3 V with SEL shorted to GNDS at 145 mA and 3.7 V with 100 kOhm from SEL to GNDS at 130 mA |
| Power ceiling | 500 mW typical at the 5.0 V setting, and about 480 mW at the two low settings because the current ceiling rises while the voltage falls |
| Efficiency | 60 per cent at 5.0 V out and 100 mA, 53 per cent at 3.7 V out, about 50 per cent at 3.3 V out and 145 mA |
| Ripple | 50 mV peak to peak at 20 MHz of bandwidth with a 10 uF and a 0.1 uF capacitor on the output |
| Regulation | 1 per cent line and 1.5 per cent load, both quoted as typical rather than as limits |
| Undervoltage lockout | rising at 4.2 V, falling at 3.7 V, with 0.5 V of hysteresis, so a slow 5 V ramp does not chatter the converter |
| Isolation | 5000 VRMS for one minute per UL 1577, 7071 VPK of maximum transient voltage, 1697 VPK repetitive peak and 1200 VRMS of working voltage |
| Common mode immunity | 100 V per nanosecond static, measured with 1000 V of common mode between the two grounds |
| Switching | internal clock from 7.2 to 8.8 MHz with 8 MHz typical, and a SYNC pin that accepts an external clock so several modules can run at one frequency |
| Start up | 750 us from enable to 90 per cent of the output at 5.0 V, and 300 us at 3.3 V, which is fast enough to follow a hot plug event |
| No-load current | 45 to 90 mA of input current depending on the output setting with the enable high, and 100 uA with the enable low |
| Short circuit | 245 mA of input current with the output shorted, and an internal reset near 1.8 V that stops the module from latching up |
| Thermal | shutdown at 165 C junction with 27 C of hysteresis |
Reading the four output settings against a real load
| 5.0 V setting, SEL to VISO | 100 mA of ceiling and 60 per cent typical efficiency, the setting to pick when the load is a 5 V sensor chain or the isolated side of a CAN transceiver |
| 5.4 V setting, 100 kOhm to VISO | 90 mA of ceiling, chosen when a downstream 5 V regulator or a gate driver bias needs headroom above 5 V |
| 3.3 V setting, SEL to GNDS | 145 mA of ceiling and about 50 per cent efficiency, the highest current of the four settings and the one to use for a logic rail behind an isolator |
| 3.7 V setting, 100 kOhm to GNDS | 130 mA of ceiling, aimed at a 3.3 V load that has to survive a small series drop on the far side |
| The SEL window | the pin is read once, in the first millisecond after the input passes the lockout or the enable goes high, and ignored after that |
| The divider domain | the programming resistor must return to the rail on the secondary side, because a divider that reaches across the barrier undoes the insulation the part was bought for |
Points to check before this part goes on a BOM
A module replaces four parts and one transformer, which is the reason it is bought. A discrete isolated bias supply needs a transformer driver, the transformer, a rectifier and a feedback path, and the creepage that makes the barrier legal has to be held by the board rather than by the vendor. Here the barrier is inside the moulding, the creepage is more than 8 mm across the package, and the safety file covers the part rather than the assembly. What is given up is flexibility. There is one input range, four output settings and no way to change the switching frequency other than by feeding the SYNC pin.
The SEL pin is sampled once and then ignored, and that single sentence causes most of the support questions on this device. The pin is read in the first millisecond after the input passes the lockout threshold or after the enable pin goes high. If a controller drives SEL after that window, the setting does not change and the output stays where it started. The second half of the same problem is where the programming resistor returns. A resistor from SEL to a rail on the primary side of the barrier works electrically on the bench and fails the isolation test, because it puts a conductive path across the very gap the part is paid for.
Efficiency of 60 per cent looks low next to a buck converter and it is the honest number for a 5 V to 5 V isolated stage. At 5.0 V out and 100 mA the load is 500 mW and the input is about 830 mW, so roughly 330 mW is dissipated inside a 10.30 mm by 7.50 mm body with no exposed pad. That heat has to leave through the pins and the board, and the ambient derating matters more than the headline figure. A board that runs the module at full load inside a sealed enclosure will find the package hot and the output drifting, and the fix is copper under the part rather than a bigger capacitor.
A shorted isolated output is handled in two stages. The input current rises to about 245 mA and an internal reset near 1.8 V on the secondary side stops the converter from trying to hold a dead rail up. If the short stays, the junction temperature climbs and thermal shutdown opens at 165 C with 27 C of hysteresis. The recovery is automatic once the short is removed, which is convenient on a fielded board and awkward during bring-up, because a board with a solder bridge on the isolated rail will look like a part that starts and stops every few seconds rather than a board with a short.
Synchronisation is the feature that keeps a multi channel product out of an emissions retest. The internal clock runs between 7.2 and 8.8 MHz, and two modules on the same board that are not synchronised will beat against each other and put a low frequency envelope on the supply current. The SYNC pin accepts an external clock, and the SYNC_OK output is an open drain flag that pulls low when no clock is present or the clock is outside the accepted range. Reading SYNC_OK at start-up is the cheap way to know whether the system clock actually arrived.
The isolation numbers in the feature list are not interchangeable. 5000 VRMS for one minute is a withstand test and it says the barrier survives a hipot. 7071 VPK is the maximum transient voltage and it describes a surge event. 1200 VRMS of working voltage is the number that governs the life of the insulation under continuous stress, and it is the figure a safety engineer will compare against the mains voltage of the end product. A part that passes the hipot and is then run at twice its working voltage will pass the production line and fail in the field, which is why the working voltage is the one to quote in a datasheet summary.
What 500 mW buys at the point of load
500 mW is enough for the loads that usually need isolation and not enough for the ones that do not. An isolated RS-485 transceiver with its isolator draws around 60 mA at 3.3 V, a CAN transceiver about 50 mA at 5 V, and a current sense amplifier plus a sigma delta modulator perhaps 30 mA. On the 3.3 V setting the 145 mA ceiling covers those with margin. A gate driver bias at 15 V and 20 mA is 300 mW and also fits, provided the 5.4 V setting is not asked to supply it directly, because the module cannot be stacked to reach 15 V without an external charge pump or a second stage.
The load that does not fit is a relay, a fan, or any rail that has to survive a brownout of the input. The module has no hold-up of its own, so the 750 us rise time at 5.0 V and the 4.2 V lockout define how long the isolated side keeps running after the primary rail collapses, and that is measured in hundreds of microseconds rather than milliseconds. A product that needs the isolated side alive across a power fail needs capacitance on the primary side, not on the secondary.
The paperwork that decides whether a purchase is approved
The certifications are UL 1577 for the isolation withstand, DIN V VDE V 0884-11 for the reinforced rating, IEC 60950-1 and IEC 62368-1 for information technology equipment, IEC 60601-1 for medical end products and a CQC certificate for the domestic market. Each one is a document the customer's safety reviewer will ask for by number, and each one is tied to the part number rather than to the board. That is the practical advantage of a certified module over a discrete supply: the safety review starts from an existing file instead of from a transformer vendor's insulation data.
The medical case is the one that changes the part choice rather than the paperwork. A 5 kVRMS reinforced barrier with 1200 VRMS of working voltage covers two means of patient protection at mains voltages that sit inside that working limit, and the appendix of the document carries the derating curves for the barrier. A product with a higher working voltage needs a different device, not a different test report, so the working voltage should be settled before the bill of materials is frozen.
Where this order code fits
This is the bias supply behind an isolated gate driver, an isolated current sense chain, an isolated RS-485 or CAN port, or the patient side of a medical monitor, where the primary rail is 5 V and the secondary side has to be certified rather than merely separated Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
Can the output be changed after power up? No. SEL is read in the first millisecond after the input passes the lockout or the enable goes high, and changes after that are ignored until the next power cycle.
How much current can it deliver at 5 V? 100 mA at the 5.0 V setting, 90 mA at 5.4 V, 145 mA at 3.3 V and 130 mA at 3.7 V. The four settings do not share one current ceiling.
Does it need an external transformer? No. The transformer is inside the package and the isolation is certified as part of the device, which is the reason the part exists.
What happens if the isolated output is shorted? The input current rises to about 245 mA, an internal reset near 1.8 V holds the secondary side down, and thermal shutdown opens at 165 C if the short stays.
Can two of them share one clock? Yes. Feed the SYNC pin from a common clock and read SYNC_OK on each part to confirm the clock arrived. Without that, the two internal oscillators beat against each other.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.