TPSM365R6V3RDNR
Product Specifications
TPSM365R6V3RDNR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPSM365R6V3RDNR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPSM365R6V3RDNR: fixed 3.3 V at 600 mA from a 0.67 uA module
The TPSM365R6V3RDNR is the fixed 3.3 V member of the family, and the order code tells the whole story: V3 for the output voltage, R for the RDN module body, and nothing else to add. There is no feedback divider on the board, no RT resistor and no mode strap, so a 3.3 V rail at 600 mA is four components: an input capacitor, an output capacitor, the module and whatever the load needs. That is the smallest solution this family offers, and it is the one that reaches 0.67 uA typical no-load current at 13.5 V in.
The input window is the same 3 V to 65 V with a 70 V transient, which means the same part covers a 12 V battery, a 24 V industrial bus and a 48 V telecom rail. A fixed output module that spans that range is unusual, and it is the reason this code shows up in gateways, meter concentrators and building controllers where the input is whatever the installer finds and the 3.3 V rail is the logic supply.
Key electrical data on the page
| Input range | 3 V to 65 V after start, 70 V transient, UVLO rising 3.4 V to 3.6 V |
| Output | 3.3 V fixed at 600 mA, with 5 V fixed and 1 V to 13 V adjustable members in the same pad |
| No-load current | 0.67 uA typical and 1.05 uA maximum at 13.5 V in, 1.2 uA typical at 24 V in |
| Switching | 200 kHz to 2.2 MHz by the internal setting, pseudo random spread spectrum for emission |
| Soft start | 2.58 ms typical, which limits the inrush into a large output capacitor bank |
| Power good | 107 percent upper and 94 percent lower window, 1.956 ms from enable to a valid flag |
| Thermal | junction to ambient 56.3 C per W, 53.9 C per W junction to case on the top |
Package, marking and reel data
| Body | QFN-FCMOD RDN, 11 pins, 4.5 mm by 3.5 mm by 2.0 mm, overmoulded with the inductor inside |
| Reel | 3000 pieces on a 330 mm reel, 17.6 mm carrier, 8 mm pitch, quadrant Q1 |
| A0 3.80 mm, B0 4.80 mm, K0 2.30 mm, carrier width 12.0 mm | |
| Finish and moisture | tin, level 3 at 260 C, 168 hour floor life |
| Marking and grade | 365R6V3 on the top, rated -40 C to 125 C junction |
What the fixed version changes for a builder
The obvious gain is two fewer components and one less tolerance to stack. The less obvious gain is that the divider is inside the module and switched off when the part is disabled, which is where the sub microamp no-load figure comes from. On a metering product that has to sit idle for years and wake on an event, that single microamp is the difference between a ten year battery and a six year one, and it is invisible on a bench supply.
The cost is flexibility. A 3.3 V rail cannot be moved to 3.6 V for a tolerant sensor, and a board that later needs 2.5 V needs a different order code rather than a resistor change. In a product family that already has three input variants and one logic rail, that is a fair trade. In a lab instrument with a custom rail, the adjustable version is the honest choice even at 17 uA, because a resistor change is cheaper than a respin.
Buyer questions on the TPSM365R6V3RDNR
Is the 3.3 V output trimmed at test or set by a divider? It is set inside the module, so there is no external divider and no divider tolerance in the rail. The accuracy figure in the datasheet is the module's own.
Can two modules be paralleled for 1.2 A? Not directly. These are voltage mode converters with no current sharing, so two in parallel will fight over the load. A 1.2 A rail needs a larger module or a converter rated for the current.
Does the module need a minimum load? No. It regulates down to zero load, and the PFM behaviour at light load is what keeps the input current at a fraction of a microamp.
Buying this part through a component supplier
The fixed 3.3 V code is the one that moves in volume, and the 3000 piece reel is a normal build quantity for a gateway programme. We supply it against the BOM line with the date code and moisture level recorded through date code management, and safety stock planning is where a customer sets the buffer for a module that is a single source on the board. When the input rail changes from 24 V to 48 V mid programme, the same pad covers both, which is one line of the power management cross reference.