Contact Us

TPS7B8233QDGNRQ1

Brand: Texas Instruments
Texas Instruments TPS7B8233QDGNRQ1 is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS7B8233QDGNRQ1 — Power Management & Signal Chain | Superb Automation

TPS7B8233QDGNRQ1

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS7B8233QDGNRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS7B8233QDGNRQ1: automotive 3.3 V, 300 mA, 40 V regulator with 2.7 uA quiescent current in an 8 pin HVSSOP body

TPS7B8233QDGNRQ1 is an automotive grade low dropout regulator that holds a 3.3 V rail from a battery that swings through cold crank and load dump, with a quiescent current low enough to stay connected with the ignition off in a HVSSOP body of 8 pins. It runs from 3 V to 40 V with a 45 V transient rating, supplies 300 mA, and holds 2 per cent output accuracy over temperature. Quiescent current is 2.7 uA typical and 6.5 uA maximum on this body, with 0.3 uA in shutdown. The HVSSOP package carries 63.9 C per watt junction to ambient, and the same die is offered in a WSON, a wettable flank WSON, a TO-252 and a 14 pin HTSSOP.

Order code and package

TPS7B8233QDGNRQ18 pin HVSSOP (DGN), 3.00 mm by 4.90 mm, 2500 pieces on a large reel, nickel palladium gold finish, moisture level 3 with a 168 hour floor life, marking 1GGX, minus 40 C to plus 150 C
TPS7B8233QDGNRQ1 .A rowthe same string repeated in the addendum with moisture level 2 and a one year floor life, which contradicts the plain row and has to be confirmed on the reel label
TPS7B8233QDRVRQ16 pin WSON (DRV), 2.00 mm by 2.00 mm, 3000 pieces on a large reel, 72.8 C per watt, marking 1ORH
TPS7B8233QKVURQ15 pin TO-252 (KVU), 2500 pieces on a large reel, 31.1 C per watt, the body for a board that has to burn the dissipation in the tab
TPS7B8233EPWPRQ114 pin HTSSOP (PWP), 2500 pieces on a large reel, 52.0 C per watt, the grade 1 option in the wider body
Temperature gradesgrade 1 is minus 40 C to 125 C ambient and 150 C junction, grade 0 is minus 40 C to 150 C ambient and 165 C junction

Electrical parameters that decide the application

Input voltage3 V to 40 V operating, 45 V transient, with an undervoltage detection at 2.7 V and 200 mV of hysteresis
Output voltage3.3 V fixed, 2 per cent accuracy on this body, while the WSON and TO-252 bodies are specified at 1.5 per cent
Output current300 mA maximum, from 1 mA to 300 mA for the accuracy specification
Quiescent current2.7 uA typical and 6.5 uA maximum on the HVSSOP body, against 1.9 uA typical and 5 uA maximum on the WSON and TO-252
Shutdown current0.3 uA with the enable pin low
Dropout voltage730 mV typical and 1350 mV maximum at 300 mA, 475 mV and 900 mV at 200 mA, 450 mV typical at 100 mA, all in this body
Current limit310 mA minimum, 510 mA typical and 690 mA maximum with the output pulled to 90 per cent of its set value
Ripple rejection60 dB at 100 Hz with a 0.5 V ripple and a 2.2 uF output capacitor
Thermal shutdown175 C junction with 20 C of hysteresis
Thermal resistance63.9 C per watt junction to ambient on the HVSSOP, 72.8 on the WSON, 31.1 on the TO-252 and 52.0 on the HTSSOP
Output capacitor1 uF to 200 uF ceramic, stable across 0.001 ohm to 5 ohm of equivalent series resistance
Enable input0.7 V maximum for a logic low and 2 V minimum for a logic high, so the pin can be driven from a 3.3 V processor

Which body and which grade

Grade 1minus 40 C to 125 C ambient and 150 C junction, the grade that covers most under hood modules
Grade 0minus 40 C to 150 C ambient and 165 C junction, for a module mounted where the ambient itself reaches 150 C
HVSSOPthe body on this page, 63.9 C per watt, moisture level 3 in the plain row and level 2 in the .A row
WSON2 mm by 2 mm, 72.8 C per watt, moisture level 2, and 1.5 per cent output accuracy instead of 2 per cent
TO-25231.1 C per watt, the lowest thermal resistance of the five, at the cost of a footprint that needs a tab
Wettable flank WSONthe same body with a visible solder fillet for camera inspection, which is the row to name when the assembly line requires one

Points to check before this part goes on a BOM

The quiescent current differs by body, and that is unusual enough to check twice. On this HVSSOP body the row reads 2.7 uA typical and 6.5 uA maximum. On the WSON and TO-252 the same die is specified at 1.9 uA typical and 5 uA maximum. The difference comes from how the leakage is measured and where the thermal path sits, not from a different die. A standby budget that quoted 1.9 uA from the front page while ordering the HVSSOP body is off by nearly a third at the maximum.

The output accuracy also depends on the body. The WSON and TO-252 rows are specified at 1.5 per cent, while the HVSSOP is 2 per cent for the 2.5 V and 3.3 V outputs and 1.5 per cent for the 5 V output. A 3.3 V rail therefore has 66 mV of total window on this body against 50 mV on the WSON. That matters for a rail that feeds a CAN transceiver with a tight supply window, and it is a strange enough specification that it is worth reading the table per body rather than from the front page.

Dropout at 300 mA is 730 mV typical and 1350 mV maximum, which is a wide spread and a large number for a 3.3 V rail. The part is built for a battery rail that spends most of its life at 12 V, so a 1.35 V worst case dropout only bites during cold crank, when the input falls to 3 V and the output is asked to hold 3.3 V. The document is explicit that the rail cannot hold 3.3 V at 300 mA below about 4.65 V of input, and a module that needs its 3.3 V rail alive through a 3 V crank needs either a smaller load or a boost ahead of the regulator.

The current limit of 310 mA minimum to 690 mA maximum is a narrow floor and a wide ceiling around a 300 mA part. The floor sits just above the rated current, which means the part can limit at 310 mA and still be within specification, so a load that draws 300 mA continuously has almost no margin against a limit that is only 3 per cent above it once the tolerance and the temperature drift are counted. The ceiling of 690 mA is what a short sees, and it is more than twice the rating.

The moisture level is contradictory inside this document and both rows describe the same order code. The plain row prints level 3 with a 168 hour floor life, and the .A row prints level 2 with a one year floor life. The conservative reading is level 3, which means an opened reel has to be used within a week or baked. A production line that plans on level 2 and receives parts marked under level 3 will find out when the reels need baking, so the reel label rather than the addendum is the authority.

The grade 1 and grade 0 options differ in ambient and junction limits, not in the die. Grade 1 stops at 125 C ambient and 150 C junction, grade 0 at 150 C ambient and 165 C junction. The thermal resistance of this body is 63.9 C per watt, so a 150 C ambient with any dissipation at all puts the junction past the grade 0 limit. In practice grade 0 with the HVSSOP is a combination that only works at light load, and a module that needs grade 0 and real current uses the TO-252 for its 31.1 C per watt.

The 40 V input with a 45 V transient is a load dump rating, not a clamp. A real load dump on a 12 V system can reach far above 45 V for hundreds of milliseconds, so the module still needs a clamp ahead of the regulator. What this rating buys is survival of the clamped transient that remains after a central suppression diode, which is the standard architecture in a body control module. A board that relies on the 45 V figure without a clamp in front of it is reading the number as a system rating rather than a device rating.

Where this order code fits

It sits in body control modules, telematics units, head units and CAN or LIN transceiver standby rails, where the module stays connected to the battery and the regulator has to be the smallest drain on the net while surviving a load dump. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Incoming Inspection Plan page.

Questions buyers ask

What is the quiescent current on this body? 2.7 uA typical and 6.5 uA maximum, against 1.9 uA and 5 uA on the WSON and TO-252 rows of the same die.

How much input headroom does 300 mA need? About 4.65 V to hold 3.3 V, because the maximum dropout at 300 mA is 1350 mV on this body. At 200 mA it falls to 900 mV.

Is this part grade 0? The QDGNRQ1 string on this page is grade 1, minus 40 C to 125 C ambient. Grade 0 options exist on other bodies such as the 14 pin HTSSOP.

What is the moisture level? The addendum prints level 3 with 168 hours on the plain row and level 2 with one year on the .A row for the same string. Treat the reel label as the authority.

What current limit should a fuse be sized against? The 690 mA maximum, because that is what a short draws. The floor is 310 mA, which is only just above the 300 mA rating.

Does the output stay in regulation through cold crank? Not at full load. Below about 4.65 V of input at 300 mA the part is in dropout and the rail follows the input down.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Date Code Management page sets out the checks that keep a substitute from failing on the bench.