Texas Instruments TPS74801RGWR 24+ is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS74801RGWR 24+ — Power Management & Signal Chain | Superb Automation

TPS74801RGWR 24+

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS74801RGWR 24+ from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS74801RGWR 24 plus catalogue row, 1.5 A in the same 20 pin VQFN

The second catalogue row for the TPS74801RGWR carries the 24 plus suffix in the internal record, and the part behind it is the same 20 pin VQFN die: 1.5 A, adjustable 0.8 V to 3.6 V, main input 0.8 V to 5.5 V, bias rail 2.7 V to 5.5 V. Two rows exist because the part is bought against two different schedules, and a buyer who reads only the first line of each quotation can end up comparing a reel of one generation against a reel of the other. The electrical answer is identical; the difference sits in the date code and in the reel the stock was cut from.

Since the family document covers both silicon generations, the field that decides the quoted accuracy is the generation letter on the label, not the suffix in the catalogue row. The current silicon is 1 per cent over line, load and temperature with 50 mV typical dropout at 1.5 A; the legacy silicon is 2 per cent with 60 mV. Both are Active. On a 1.2 V core rail fed from 1.8 V, that difference in dropout is 10 mV of headroom, and the accuracy difference is the reason a set point can drift between builds that use different generations.

Key parameters printed in the SBVS074N document

Input range0.8 V to 5.5 V, floor also set by output plus dropout
Bias rail2.7 V to 5.5 V, 1 mA typical of bias current
Output range0.8 V to 3.6 V adjustable from a 0.8 V reference
Load current1.5 A continuous, current limit 2 A to 5.5 A
Accuracy1 per cent current silicon, 2 per cent legacy silicon, over line, load and temperature
Dropout50 mV typical at 1.5 A on the current silicon, 60 mV on the legacy silicon
Rejection60 dB at 1 kHz and 50 dB at 300 kHz at 1.5 A on the current silicon
ShutdownBelow 1 microamp typical with the enable held low, 15 microamp maximum on the current silicon

Package, reel and top side marking

PackageVQFN, RGW body, 20 pins, exposed thermal pad
Reel3000 pieces on a large tape and reel, 250 piece small reel on the DRC body only
Finish and moistureNickel palladium gold, moisture level 2, one year floor life
Temperature and markingMinus 40 to plus 125 degrees junction, top side marking TPS 74801

Why one part carries two catalogue rows

Two catalogue rows for one part is not a defect, it is a stock record. The practical rule is to order against the row that carries the reel size and the date code the build needs, and to write the generation into the receiving inspection plan so a mixed delivery is caught at the door rather than at the tester. Where a program runs for years, the second row is also the natural place to hold a buffer that keeps a line running while the first row is on allocation. The safety stock planning page sets out how that buffer is sized against the call off rather than against the annual volume.

The thermal side does not change between rows. 1.5 A from 3.3 V to 1.2 V is 3.15 W, which is beyond the 20 pin body without a copper area to spread it, and the junction to ambient figure in the document assumes a JEDEC high K board. A four layer board with a via array under the pad is the minimum; a two layer board at that dissipation will trip the thermal shutdown at 165 degrees and cycle the rail rather than fail outright, which is the harder fault to diagnose. The power management cross reference page lists the bodies that can replace this one when the dissipation has to be split across two rails.

Questions buyers ask before ordering

Is the 24 plus suffix a different part? No. It is the internal record for the second catalogue row of the same orderable code, so the electrical table and the footprint are the same.

Can the rows be mixed in one build? They are the same orderable code, so the reels are interchangeable. Write the generation into the inspection plan if the drawing quotes 1 per cent accuracy, because the legacy silicon does not meet it.

Does the small reel apply here? The 250 piece small reel in the addendum sits against the DRC body. This row is the RGW body at 3000 pieces, so a small quantity order is a cut reel rather than a factory small reel.

Ordering this part through SUPERB

SUPERB holds both catalogue rows, reads the generation and the date code off the reel, and quotes against the row that matches the build date rather than the row that happens to be cheapest that week. A bill of materials line with the target date is enough to start; send it through the date code management page and the answer names the reel size, the moisture level and the generation.