TPS70950QDRVRQ1
Product Specifications
TPS70950QDRVRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS70950QDRVRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS70950QDRVRQ1: a 5.0 V, 150 mA automotive regulator in a 2 mm by 2 mm WSON that holds 1 uA of quiescent current and blocks reverse current from the output into the input
TPS70950QDRVRQ1 is a linear regulator with a band gap and an error amplifier that holds 2 per cent over temperature, a pass element that leaks 1 uA when the load is asleep, and a reverse current path that goes high impedance so a charged output cannot discharge into a dead input in a WSON body of 6 pins. The DRV body is six pins on a 2.00 mm by 2.00 mm pad, and the part exists for the rails that stay powered while the vehicle is parked.
Order code and package
| Catalogue string | TPS70950QDRVRQ1, where 50 is the 5.0 V fixed output, Q1 is the automotive qualifier and DRV is the six pin WSON |
| Body | WSON, DRV, six pins, 2.00 mm by 2.00 mm, with the same die sold in a five pin SOT-23 as the DBV body |
| Reel | 3000 pieces on a large tape and reel on the DRV row |
| Finish and moisture | NIPDAU plating, level 1 at 260 C, which means unlimited floor life and no bake on the line |
| Temperature | minus 40 to 125 C, AEC-Q100 grade 1, with the junction figure quoted rather than an ambient figure |
| Marking | SJL on the DRV row, and a different three letter code on each fixed voltage in the family |
| Document | SLVSCE6D, December 2013, revised August 2025 |
| Status | Active and in production on the addendum dated November 2025 |
Electrical parameters that decide the application
| Input range | 2.7 V to 30 V, so a 5 V rail and a 24 V truck rail both run from the same part without a pre regulator |
| Output | 5.0 V fixed with 2 per cent accuracy over the full temperature range, not a 25 C figure |
| Quiescent current | 1.4 to 2.7 uA at 100 uA of load and 6.7 to 10 uA at 150 mA, which is the difference between a 1 uA headline and the current at full load |
| Shutdown | 150 nA typical with the enable pin below 0.4 V, so a parked module draws nothing measurable |
| Current limit | 200 to 500 mA with 320 mA typical, and the regulator only holds regulation up to 150 mA |
| Peak output | 200 mA is supported for short bursts, which is what a radio transmit slot or a relay coil asks for |
| Dropout | 975 mV typical and 1540 mV maximum for the 5 V member measured at 50 mA, and the table states that dropout is only valid for outputs at or above 2.8 V |
| Reverse current | the pass path goes high impedance when the output is above the input and leakage falls to 10 nA typical, active regardless of the enable state above 1.8 V of output |
| Reverse bias ceiling | the most that may be applied to the output with the input live is the lower of three times the nominal output or 6.5 V, which is 6.5 V on this 5 V part |
| Rejection | 62 dB at 100 Hz and 52 dB at 1 kHz, with 190 uVrms of noise over 10 Hz to 100 kHz at 10 mA |
| Thermal shutdown | 158 C on the way up and 140 C on the way down, so a fault cycles the regulator rather than latching it off |
| Enable | 0.9 V minimum to turn on and 0.4 V maximum to turn off, with 100 nA of pin current |
What changes across the fixed voltage members
| TPS70950QDRVRQ1 | 5.0 V, WSON six pin, 3000 pieces on a large reel, marking SJL, this page |
| TPS70950QDBVRQ1 | the same die and the same 5.0 V output in the five pin SOT-23, 3000 pieces, marking SLX |
| TPS70933QDRVRQ1 | 3.3 V in the WSON, marking SJK, the version to pick when the rail is a processor supply |
| TPS70936QDBVRQ1 | 3.6 V in the SOT-23, marking SLW, for a 3.6 V rail that has to survive a 24 V jump start event |
| TPS70930QDRVRQ1 | 3.0 V in the WSON, marking SJJ, which sits under the dropout floor for a 5 V input but fits a 12 V bus |
| TPS70912 and the low voltage members | down to 1.2 V, and on those the reverse bias ceiling drops with the three times rule rather than staying at 6.5 V |
Points to check before this part goes on a BOM
The 1 uA headline is real but it is not the whole current. The regulator holds 1.4 to 2.7 uA at 100 uA of load and rises to 6.7 to 10 uA at 150 mA, because the pass element and the band gap both need current once the load current is large. A module that sleeps at 100 uA sees the low figure and a module that runs a radio at full power sees the high one. Quoting 1 uA in a power budget for a continuously transmitting node understates the idle draw by a factor of several, and the error only shows up after a week on a battery.
Reverse current protection is the reason this part is on an automotive rail and not a generic LDO. When the output is held up by a charged capacitor and the input collapses, a conventional regulator pulls current backwards through the pass element and the body diode, and the input rail is dragged up or the pass element is damaged. Here the pass path goes high impedance and leakage falls to about 10 nA, and the protection stays active regardless of the enable pin and whenever the output is above 1.8 V. Below 1.8 V of output the protection stops, so a rail that is only partly charged can still pull current.
The reverse bias ceiling is a hard limit that is easy to miss. With the input live, the most that may be applied to the output is the lower of three times the nominal output voltage or 6.5 V. On the 5 V part that is 6.5 V, which is fine. On the 1.2 V part it is 3.6 V, so a 5 V rail that is sequenced before the regulator can sit on the output and exceed the limit while the input is present. That is a sequencing problem, and this data sheet states the number plainly rather than leaving it to be found in a note.
Dropout is quoted for a 5 V output at 50 mA as 975 mV typical and 1540 mV maximum, and the table adds that dropout is only valid for outputs at or above 2.8 V because of the 2.7 V minimum input. For a 5 V rail on a 12 V bus that is irrelevant. For a 5 V rail on a 6 V bus it is the whole question, because 1540 mV of maximum dropout leaves nothing at all and the regulator falls out of regulation at around 6.5 V of input before any load transient. A 5 V rail that must hold through a 6 V cranking event needs a different topology, not a different LDO.
The current limit is not a short circuit rating. It begins to limit between 200 and 500 mA while the device is characterised only to 150 mA, so a fault holds the pass element in a resistive state and the package dissipates the difference until thermal shutdown arrives at 158 C. In a 2 mm by 2 mm body that is a few hundred milliseconds at 12 V of input, and the regulator then cycles between current limit and thermal shutdown for as long as the fault is present. A load that can fail short needs a series resistor or a fuse, and the LDO thermal cycle is a backstop.
Grade 1 with the junction range to 125 C is the qualification claim, and the parts are sold in a WSON with level 1 moisture sensitivity. Level 1 means unlimited floor life, which for a contract assembly line is worth real money on a part that sits in a feeder for a week. The SOT-23 sibling prints the same level, and both bodies carry NIPDAU plating, so a board that mixes the two packages does not need two reflow profiles.
Power budget arithmetic for a parked module
Take a telematics box that keeps a 5 V rail alive for a CAN transceiver and a supervisor. The transceiver draws 2 mA in standby, the supervisor draws 10 uA, and the regulator adds 6.7 to 10 uA at that load. The total is about 2.02 mA, and on a 60 Ah battery that is 105 days of standby before the battery reaches half charge, which is the kind of number a parked vehicle programme is judged on. A generic 5 mA quiescent regulator would flatten the same battery in 100 days.
Now add a radio that wakes for 100 ms every ten seconds and draws 200 mA from the rail. The peak is inside the 200 mA burst capability, the average rises to about 4 mA, and the regulator's own draw at that average is near the 10 uA ceiling. The standby budget is now dominated by the load and not by the LDO, which is exactly where the error should sit in a standby budget.
Where the 30 V input actually helps
A 30 V input rating covers a 24 V rail with a nominal tolerance and a modest transient, and it covers a 12 V rail through a load dump only if the transient is clamped. It does not cover an unclamped 24 V load dump, which reaches far above 30 V, so a board that must survive one needs a clamp ahead of the regulator. The distinction matters because the input rating is often read as a load dump rating and the two are not the same.
The other use of the wide input is a two stage rail. A 24 V bus feeds the 5 V rail through this part with 19 V of drop at 150 mA, which is 2.85 W in a 2 mm by 2 mm body. The thermal path is the limiting factor long before the current limit, so a 24 V to 5 V drop at more than about 30 mA needs a switching stage and this part only as a post regulator.
Where this order code fits
This is the always on rail in a body control module, a telematics unit, an instrument cluster, a camera module or a remote sensor node, where the regulator has to hold 5 V from a battery that swings from 6 V while cranking to 18 V while charging and has to draw almost nothing when the vehicle is parked Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Obsolescence Management page.
Questions buyers ask
Is 1 uA the current at full load? No. It is 1.4 to 2.7 uA at 100 uA of load and 6.7 to 10 uA at 150 mA. The 1 uA figure is the headline typical at light load.
What happens if the output is held above the input? The pass path goes high impedance and leakage falls to about 10 nA, provided the output is above 1.8 V and the applied voltage is inside the three times nominal ceiling.
Can it supply 200 mA continuously? The device is characterised to 150 mA. The 200 mA figure is a peak capability, and continuous operation there is outside the specifications.
Does it work from a 24 V rail? Yes, the input range is 2.7 V to 30 V, so a 24 V rail with a modest tolerance is inside the rating. An unclamped load dump is not.
Why is dropout only specified above 2.8 V of output? Because the minimum input is 2.7 V, so below a 2.8 V output the part is already at its input floor and a dropout measurement would mean nothing.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Date Code Management page sets out the checks that keep a substitute from failing on the bench.