TPS62410DRCR
Product Specifications
TPS62410DRCR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS62410DRCR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS62410DRCR: 2.5 V to 6 V dual 800 mA step down converter at 2.25 MHz
TPS62410DRCR is a two channel synchronous buck in one 3 mm by 3 mm body, with independent enables and a shared mode pin in a VSON body of 10 pins. It replaces two single converters on a board that needs a core rail and an input output rail from the same 3.3 V or 5 V source.
Order code and package
| Order code | TPS62410DRCR, DRC package, 3000 pieces on a large reel |
| Body | VSON, 3.0 mm by 3.0 mm, ten pins with a thermal pad |
| Channels | Two independent converters at 800 mA each, separate enables and separate feedback |
| Output setting | Converter 1 by a resistor network on DEF_1, converter 2 by a divider on ADJ2 |
| Reference | 600 mV, with -1 per cent to 1 per cent DC accuracy in forced PWM |
| Rating | -40 C to 85 C ambient, 2.05 W at 25 C in still air with 21 mW per C derating |
Electrical parameters that decide the application
| Input range | 2.5 V to 6 V operating, under voltage lockout falling between 1.5 V and 2.35 V |
| Output current | 800 mA per channel, forward current limit 1.0 A minimum and 1.2 A typical |
| Output range | 0.6 V to VIN, adjustable |
| Switches | P channel 280 mOhm typical and 620 mOhm maximum, N channel 200 mOhm typical and 450 mOhm maximum |
| Switching frequency | 2.25 MHz fixed, 2.0 MHz to 2.5 MHz |
| Quiescent current | 19 uA with one channel in power save, 32 uA with both, 3.6 mA in forced PWM |
| Shutdown current | 1.2 uA typical and 3 uA maximum with both enables low |
| Soft start | 170 us to start switching and 750 us to ramp, internal |
| Mode pin | Power save or forced PWM, and the one wire EasyScale data input |
| Protection | Current limit on both switches of each channel, thermal shutdown at 150 C with 20 C of hysteresis |
Family variants and how they differ
| TPS62400 and TPS62420 | members of the same family with different default output voltages and current ratings |
| TPS62130 | a single 3 A channel in the same body size, for a board that needs one rail rather than two |
| TPS62201 | a single 300 mA fixed output in a SOT-23, for a much lighter load |
| TPS562212 | 2 A from 18 V in an eight pin body, a single channel alternative |
| TPS56C215 | 12 A from 17 V, for a load orders of magnitude larger |
Points to check before this part goes on a BOM
The two channels are not symmetrical, and this is the detail that costs a board spin. Converter 1 sets its voltage with an analog resistor network on DEF_1 while FB1 is tied directly to the output, and converter 2 uses a conventional divider into ADJ2 against the 600 mV reference. An engineer who copies channel 1 to channel 2, or the other way round, gets a rail that sits at the wrong voltage with no obvious fault.
Power save and forced PWM differ by a factor of about 190 in standing current, 19 uA against 3.6 mA for one channel. Power save drops cycles and lets the output ripple grow, forced PWM holds 2.25 MHz at all loads for a clean spectrum. A radio rail usually wants forced PWM, a standby rail usually wants power save, and the mode pin sets it for both channels at once.
The current limit is 1.0 A minimum per channel against an 800 mA rating, a 25 per cent margin that is adequate only because 2.25 MHz keeps the ripple small. A 2.2 uH inductor at 2.25 MHz gives about 0.3 A of peak to peak ripple at 3.6 V in, so the peak sits at 950 mA and the limit is just above it. A smaller inductor or a lower frequency raises the peak and the channel folds back earlier than the rating suggests.
The thermal rating is the number to work against, 2.05 W at 25 C with a 21 mW per C derating, which is 790 mW at 85 C ambient. Both channels at 800 mA from 3.6 V to 1.8 V dissipate about 0.15 W each in conduction plus switching, so a 0.4 W total is comfortable, but a board that runs both channels at 800 mA with a 5 V input and a 1.2 V output has to add the switching loss and check the derated figure.
The 170 us start-up and 750 us ramp mean the two rails are ready in under a millisecond, which is fast enough that a processor can be released almost immediately after the enables. The two channels start independently, so a system that needs channel 2 to come up after channel 1 has to sequence the enables from the host rather than rely on the part, since there is no internal tracking between the channels.
The mode pin carries data as well as a level. In one state it selects power save or forced PWM, in the other it accepts an EasyScale word that changes the output voltage of converter 2 while the part is running. That is how a system adjusts a rail for a process corner without a second part, and it is also why the pin cannot simply be tied to ground on a board that later wants to use the feature.
A 2.35 V falling lockout against a 2.5 V minimum input leaves very little margin. A 2.5 V rail at minus ten per cent is 2.25 V, which is below the lockout, so a build that runs from a 2.5 V source has to check the low line and the load transient sag. The 3.3 V and 5 V rails this part is usually used on have no such problem, which is why the datasheet examples are all at those voltages.
The shutdown current of 1.2 uA typical applies with both enables low, and the reverse leakage into the switch pins when off is 6 uA to 7.5 uA, which is a real term on a battery node. A board that keeps one channel alive and shuts the other down has to count the quiescent of the live channel plus the leakage of the dead one rather than the 19 uA headline alone.
The 600 mV reference is low, which keeps the divider current small for a given output, and it also means the feedback node is a high impedance point that is sensitive to noise at 2.25 MHz. The divider should sit close to the pin with a short return, and the output capacitor should be placed against the inductor and the ground pin rather than at the far end of the rail, otherwise the loop sees the trace inductance as part of the output.
Where this order code fits
It belongs in a portable device, a modem, a camera module, a point of sale terminal or an industrial sensor, where a 3.3 V or 5 V input has to feed a 1.2 V core and a 1.8 V or 2.5 V input output rail from one small package. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.
Questions buyers ask
Can both channels be set with one resistor each? No. Channel 1 uses an analog network on DEF_1 with FB1 tied to the output, channel 2 uses a divider on ADJ2 against 600 mV. The two are different circuits.
What is the current per channel? 800 mA rated with a 1.0 A minimum forward limit. The 25 per cent margin assumes the ripple that 2.25 MHz and a 2.2 uH inductor produce.
Does it work from a 2.5 V rail? The lockout falls between 1.5 V and 2.35 V, so a 2.5 V rail at minus ten per cent is 2.25 V and may not start. Use a 3.3 V or 5 V input where possible.
Can the output voltage change while running? Yes, on channel 2 through the EasyScale one wire interface on the mode pin, which is the same pin that selects power save or forced PWM.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the One Stop BOM Sourcing page sets out the checks that keep a substitute from failing on the bench.