Contact Us

TPS61220DCKR

Brand: Texas Instruments
Texas Instruments TPS61220DCKR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS61220DCKR — Power Management & Signal Chain | Superb Automation

TPS61220DCKR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS61220DCKR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS61220DCKR: 0.7 V input boost converter, adjustable output to 6 V, 5.5 microamp quiescent, SC-70-6

TPS61220DCKR is a synchronous boost converter that starts from 0.7 V and holds an adjustable output between 1.8 V and 6 V with a quiescent current of 5.5 microamp in a SC-70 body of 6 pins. The input range starts at 0.7 V, which is below the end point of a single alkaline cell, so a device keeps working until the cell is genuinely flat rather than stopping at 0.9 V. The converter is hysteretic rather than fixed frequency, which keeps the quiescent current low and the part count small.

Order code and package

TPS61220DCKRActive, SC-70-6, 3000 pieces on a large reel, NIPDAU finish, MSL-1-260C unlimited floor life, marking CKR
TPS61220DCKRG4Active, the same body and reel with the Green material declaration
TPS61221DCKthe 3.3 V fixed member of the family, marking CKS
TPS61222DCKthe 5.0 V fixed member, marking CKT
Temperature rangeminus 40 to 125 degrees on the published rows

Electrical parameters that decide the application

Input voltage0.7 V to 5.5 V operating, with start up into a load at 0.7 V
Outputadjustable from 1.8 V to 6 V through an external divider on this string
Quiescent current5.5 microamp typical
Switch current200 mA minimum peak switch current
Efficiencyup to 95 per cent at typical operating conditions
Topologyhysteretic control with synchronous rectification
Shutdownpass through function, so the input reaches the output through the inductor
Protectionoutput overvoltage, overtemperature, input undervoltage lockout

Family variants and how they differ

TPS61220adjustable output, the string on this page
TPS61221fixed 3.3 V, no divider needed
TPS61222fixed 5.0 V, for a rail that has to sit above a 3.3 V system
Bodysix pin SC-70 at 2 mm by 1.25 mm
Inductor4.7 microhenry typical, chosen for the current at the lowest input voltage

Points to check before this part goes on a BOM

Starting at 0.7 V is the point of the part. A boost converter that needs 0.9 V to start leaves usable energy in an alkaline cell. Starting at 0.7 V into a load means the device runs until the cell is genuinely exhausted, which on a low duty cycle product can be months of extra life. The start up capability is specified into a load, not into an open circuit, which is the honest way to read it.

Hysteretic control means the switching frequency is not fixed. The converter switches when the output falls below a threshold and stops when it rises above another. That gives excellent efficiency at light load and a spectrum that spreads with the load. It also means the ripple is larger and less predictable than a fixed frequency part, which matters when the boosted rail feeds an analogue circuit.

The pass through in shutdown is a feature with a consequence. When the part is disabled the input reaches the output through the inductor and the body diode, so the load sees the battery voltage minus a diode drop. That is useful when a system wants to run directly from the battery with the boost off, and it is a problem when the load must be isolated, in which case a load switch is needed in series.

Two hundred milliamp of switch current is not 200 mA of output. The output current depends on the ratio. At 0.9 V in and 3.3 V out the available output current is a fraction of the switch current because the input current is several times the output current. At 1.8 V in and 3.3 V out the same switch delivers more. The data sheet curves are the only honest way to quote this part.

5.5 microamp is the no load figure and it sets the shelf life. A 1000 milliamp hour cell loses 48 milliamp hour a year to the converter alone. For a product that is switched on for a few minutes a day that is acceptable; for one that is always boosting it is not, and the enable pin should be used to shut the converter down between measurements.

The output divider is live in shutdown. On the adjustable version the divider from the output to the feedback pin keeps drawing current even when the converter is off, and through the pass through path that current comes from the battery. A high value divider, in the megohm range, keeps that loss small; a low value divider chosen for noise immunity can drain a coin cell.

A four point seven microhenry inductor is the starting point, not a rule. The inductor has to carry the peak current at the lowest input voltage the product will see, and its series resistance adds directly to the loss in a boost. A small inductor with high resistance will pass a bench test at 3 V in and fail at 1 V in, when the input current is highest.

The fixed output members are a different order code, not a setting. TPS61221 gives 3.3 V and TPS61222 gives 5.0 V with the feedback divider inside. A board built for the adjustable part has the divider on the board, so fitting a fixed member leaves that divider in parallel with the internal one and produces the wrong voltage. Repair stock has to match the string.

Output overvoltage protection is there for an open load. A boost converter with no load and no overvoltage limit runs the output up until something breaks. The protection clamps the output, which is why the part survives a connector that comes loose. It does not protect a load that is connected and draws too little; that is a system level decision.

What to confirm before this part goes on a purchase order

Confirm whether the board uses the adjustable version with an external divider or a fixed member. The three strings share a package and a pinout but not a function, and a reel of the fixed part in place of the adjustable one produces a rail that is close but wrong.

Ask for the date code and the marking, and check that the offer names the country of origin. For a product that runs from a single cell the input current at low battery is the highest current on the board, so a part from an uncertain source is a reliability risk that shows up as a failure in the field rather than on the bench.

Where this order code fits

It lifts a single alkaline cell at 0.9 V to a 3.3 V rail for a handheld meter or a wireless sensor node, and keeps boosting until the cell is flat. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.

Questions buyers ask

Can it start from a single alkaline cell at 0.9 V? Yes, and it can start into a load from 0.7 V. The available output current at that input is small because the input current is several times the output current, so the load has to be checked against the curves for the actual cell voltage.

Is the switching frequency fixed? No. The converter is hysteretic, so the frequency follows the load and the input voltage. That is good for efficiency at light load and less good for a predictable ripple spectrum.

What happens to the output when the part is disabled? The input reaches the output through the inductor and the body diode, so the load sees the battery minus a diode drop. If the load must be isolated, a load switch has to be added in series with the converter output.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.