TPS61070DDCR
Product Specifications
TPS61070DDCR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS61070DDCR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS61070DDCR: 0.9 V to 5.5 V input synchronous boost, 600 mA switch, SOT-23-6
TPS61070DDCR is a synchronous boost converter with a 600 mA peak switch current that starts from 0.9 V and holds an adjustable output up to 5.5 V in a SOT-23 body of 6 pins. The converter runs at a fixed switching frequency in continuous mode and drops into power save at light load, which keeps efficiency high across three decades of load current. During shutdown the load is disconnected from the battery, so a device that is switched off does not drain the cell through the inductor.
Order code and package
| TPS61070DDCR | Active, SOT-23-6 thin, 3000 pieces on a large reel, NIPDAU finish, MSL-1-260C unlimited floor life, marking AUH |
| TPS61070DDCRG4 | Active, the same body and reel with the Green material declaration |
| TPS61071 and TPS61072 | the fixed frequency members without power save mode, for loads that cannot tolerate pulse skipping |
| TPS61073 | the power save member with a different output option in the same body |
| Temperature range | minus 40 to 85 degrees on the DDC rows |
Electrical parameters that decide the application
| Input voltage | 0.9 V to 5.5 V |
| Output | adjustable up to 5.5 V through an external divider |
| Switch current | 600 mA peak, limited internally |
| Quiescent current | 19 microamp typical |
| Output current | 75 mA at 3.3 V from 0.9 V in, 150 mA at 3.3 V from 1.8 V in, 200 mA at 5 V from 3.3 V in |
| Efficiency | up to 90 per cent |
| Switching | fixed frequency PWM in continuous mode, power save at light load |
| Shutdown | load disconnected, so the battery sees no path through the inductor |
Family variants and how they differ
| TPS61070 | power save mode, the string on this page |
| TPS61071 | no power save, fixed frequency across the load range |
| TPS61072 | no power save, a different feedback option in the same body |
| Inductor | 4.7 microhenry typical for the 3.3 V application |
| Body | 2.9 mm by 1.6 mm, six pins, no thermal pad |
Points to check before this part goes on a BOM
The 600 mA switch current is the limit, not the output current. At 0.9 V in and 3.3 V out the input current is nearly four times the output current, so the switch limit leaves around 75 mA at the output. At 1.8 V in the same switch delivers 150 mA. Quoting the part as a 600 mA converter is the most common way a boost is specified wrongly, and the mistake shows up as a rail that sags when the cell is nearly flat.
Power save mode is a choice between efficiency and ripple. TPS61070 enters pulse skipping at light load and holds efficiency above 80 per cent down to microamp loads. TPS61071 stays at fixed frequency and burns more current at light load but keeps the ripple and the spectrum clean. For a radio rail the second is often the right answer even though the headline efficiency is worse.
Load disconnect during shutdown is a real function. A boost converter normally has a DC path from input to output through the inductor and the body diode, so the load stays powered when the converter is off. This part breaks that path, which is why it appears in products that are stored for months. The shutdown current quoted in the data sheet only means something with that path broken.
Nineteen microamp is the device current, not the system current. The feedback divider adds to it, and on a 5 V output a divider that draws 5 microamp doubles the budget. A high value divider in the megohm range is standard on this part, and the feedback pin bias current is low enough to allow it.
The output cannot go below the input. This is a boost, so at 4.2 V in a 3.3 V output is not regulated, it is the input minus the diode and switch losses. A lithium cell that starts at 4.2 V will pass straight through at the top of its charge. A product that needs 3.3 V across the whole cell range needs a buck boost, not a boost.
Fixed frequency does not mean a clean spectrum at all loads. In power save the part skips pulses, and the skip rate depends on the load. Even the fixed frequency members change behaviour at start up, when the output is charging and the current limit dominates. Emissions testing at a single load point can hide the worst case.
Eighty five degrees is the ambient limit on the DDC rows. A boost running at a high duty cycle dissipates more than a buck at the same output power, because the input current is higher. In a sealed enclosure at 70 degrees the junction margin is thin, and a part rated to 85 is not the same as a part rated to 125.
Output overvoltage protection matters for an LED or a connector load. A boost with an open output runs away until something fails. The internal protection clamps the output, which is why the part survives a load that is disconnected while running. It does not replace a proper clamp on a long cable, where the inductance can spike the output above the clamp response time.
The four family members are not interchangeable on a board. They share a body and a pinout, but the power save behaviour and in one case the feedback arrangement differ. A board qualified with TPS61070 and repaired with TPS61071 will work and will show a different light load current, which matters on a battery product and can be the difference between meeting a standby specification or not. The four strings also sit on different stock positions, so a mix up is usually discovered only when the standby current is measured, long after the reels have been consumed.
What to confirm before this part goes on a purchase order
State the input range and the output current at the lowest input voltage, not the nominal one. The switch current limit decides what the part can deliver at 0.9 V in, and that is the number the customer actually needs.
Confirm whether the product needs power save or fixed frequency, because two of the four family members look identical on a reel. Ask for the marking AUH and the date code, and keep the reel sealed until the line is ready.
Where this order code fits
It runs a 3.3 V or 5 V rail at up to 200 mA from one lithium cell in a portable instrument, and disconnects the load completely when it is switched off. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.
Questions buyers ask
Can it give 5 V at 500 mA from a single cell? No. The switch current limit of 600 mA peak caps the output at roughly 200 mA for 5 V out from a 3.3 V input, and much less from a single cell at 0.9 V. The output current has to be read from the curves for the actual input voltage.
What is the difference between this and the TPS61071? The power save behaviour. This part skips pulses at light load for efficiency; the 61071 stays at fixed frequency for a clean spectrum. They share a body and a pinout and differ in light load current and ripple.
Does the output stay connected when the part is off? No, the load is disconnected during shutdown. That is the reason the shutdown current is quoted as low as it is, and it is why the part suits products that sit unused for long periods.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the OEM Procurement page sets out the checks that keep a substitute from failing on the bench.