TPS61022RWUR
Product Specifications
TPS61022RWUR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS61022RWUR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS61022RWUR: an 8 A valley current boost converter that starts from 1.8 V and runs down to 0.5 V
TPS61022RWUR is a synchronous boost converter with a 12 milliohm low side switch, a true disconnect path and a selectable light load mode in a VQFN-HR (RWU) body of 7 pins. It takes 0.5 V to 5.5 V in, starts at 1.8 V, and holds an output between 2.2 V and 5.5 V with a 600 mV reference. The two switches are 12 milliohm on the low side and 18 milliohm on the high side, the valley current limit is 8 A with a 6.5 A minimum over temperature, and the converter reaches 94.7 per cent at 3.6 V in and 5 V out at 3 A. Switching is 1 MHz above 1.5 V in and falls to 0.6 MHz below 1 V, which is what lets a supercapacitor run down without the loop losing control. Quiescent current from the output is 27 microamp, and the load is fully disconnected when the part is off.
Order code and package
| TPS61022RWUR | VQFN-HR body of 7 pins measuring 2.00 mm by 2.00 mm, 3000 pieces on a large reel, moisture level 2 at 260 C with one year of floor life, marking 1UNF or 2GZH depending on the assembly row, active status in the package addendum |
| Mode pin | selects automatic power save or forced PWM at light load, which is the choice between efficiency and a fixed ripple spectrum |
| Enable pin | a logic input, and with it low the output is disconnected from the input rather than left on a diode path |
| Feedback | an external divider against the 600 mV reference, so the output is set between 2.2 V and 5.5 V by two resistors |
| Pass through | when the input rises above the target output the converter stops switching and passes the input through with the high side switch held on |
| Body | 2 mm by 2 mm with a thermal pad, which is the only heat path for a converter that can pass 8 A through the low side switch |
Electrical parameters that decide the application
| Input voltage | 0.5 V to 5.5 V, with 1.8 V needed to start and the converter continuing to run below that once it is up |
| Output voltage | 2.2 V to 5.5 V set by a divider against a 600 mV reference, with 585 mV to 615 mV over the part in PWM mode |
| Switch resistance | 12 milliohm on the low side and 18 milliohm on the high side, which is a low figure for a converter in a 2 mm body |
| Valley current limit | 8 A typical with a 6.5 A minimum over the full temperature range, and this is the switch current rather than the output current |
| Output current | set by the input to output ratio and the valley limit, so 3 A at 5 V out from 3.6 V in is inside the window and a higher ratio reduces it |
| Switching frequency | 1 MHz above 1.5 V in, falling gradually to 0.6 MHz as the input drops from 1.5 V to 1 V, and the switch stays controlled below that |
| Quiescent current | 27 microamp typical and 32 microamp maximum from the output with the part enabled, no load and not switching, plus under 3 microamp from the input |
| Shutdown current | 0.25 microamp typical and 3.5 microamp maximum with the part disabled, which is the figure that decides how long a stored product keeps its charge |
| Overvoltage protection | 5.5 V minimum, 5.7 V typical and 6.0 V maximum on a rising output, with hysteresis before the switch resumes |
| Soft start | 700 microsecond internal ramp from enable to regulation, which is what limits the inrush into the output capacitor |
| Undervoltage lockout | 1.7 V to 1.8 V rising with the output at zero, and 1.3 V to 1.6 V rising once the output is above 2.2 V, which is the behaviour that allows a deep discharge start |
| Output accuracy | plus or minus 2.5 per cent on the reference over minus 40 C to 125 C, which the divider tolerance sits on top of |
Operating modes and the pins that select them
| TPS61022 | this member, 8 A valley limit, 0.5 V to 5.5 V input, true disconnect in shutdown, 2 mm by 2 mm VQFN |
| Mode pin | automatic power save or forced PWM, which is the choice between light load efficiency and a fixed ripple spectrum |
| Pass through | above the target output the converter stops switching and passes the input through the high side switch |
| Reference | 600 mV with plus or minus 2.5 per cent over temperature, so the divider sets the output between 2.2 V and 5.5 V |
| Overvoltage protection | 5.7 V typical on a rising output, which is the limit for a 5 V rail that must not be driven higher |
| Start and run | 1.8 V to start and 0.5 V to keep running, which is the pair of numbers a supercapacitor backup is planned around |
| Frequency | 1 MHz above 1.5 V in, falling to 0.6 MHz below 1 V, so the loop keeps control as the source collapses |
Points to check before this part goes on a BOM
Starting at 1.8 V and running at 0.5 V are two different numbers. The converter needs 1.8 V to start because the control circuit has to come up first. Once it is running it will follow the input down to 0.5 V, which is what makes a supercapacitor backup work: the capacitor has to be charged to 1.8 V, and after that it can be emptied.
The valley current limit is 8 A of switch current. The output current is smaller and depends on the input to output ratio. A 3 A load at 5 V out from 3.6 V in draws about 4.6 A from the input, which is inside the limit, and the same load from a 2.5 V input does not fit.
True disconnect is a specification, not a mode. With the enable low the output is separated from the input, so a charged output does not leak back into a dead source and a source does not feed the load through a body diode. That is what allows the part to sit between a battery and a rail that must go to zero.
The frequency falls with the input on purpose. Below 1.5 V the on time would be too short to control at 1 MHz, so the oscillator slows to 0.6 MHz. The result is a converter that keeps regulating instead of skipping pulses and dropping out.
Pass through is not the same as a bypass switch. Above the target output the high side stays on and the input appears at the output minus the drop across that switch. A 5 V source feeding a 4.5 V target therefore delivers about 4.5 V plus the load drop, not a regulated value.
The 2 mm body has one heat path. At 8 A of valley current the low side switch dissipates, and the pad is the only way out. A board that leaves the pad on a thin trace will current limit early or heat the part until the thermal protection trips.
Where a 0.5 V input boost is used
A supercapacitor stack for a backup rail, a single cell with a nearly empty battery, and a thermoelectric or energy harvesting source all sit at voltages where a conventional boost cannot start. This part starts at 1.8 V and then tracks the source down, which is the behaviour a backup rail needs.
The same property is used on a product that has to keep a real time clock and a memory alive from a coin cell: the converter starts on the fresh cell and keeps running as the cell falls, instead of dropping out at 1.8 V with most of the energy still inside.
What the mode pin changes in a measurement
In forced PWM the converter switches at a constant frequency at light load, so the output ripple is a clean waveform and the input current has no low frequency component. In power save mode the switching bursts, which raises the light load efficiency and puts a low frequency envelope on the input current that a sensitive analog rail can pick up.
Where this order code fits
a supercapacitor or single cell backup rail, a portable instrument or an energy harvesting node that has to hold 3.3 V or 5 V from a falling source Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.
Questions buyers ask
Can it start from a single alkaline cell? It needs 1.8 V to start, so one fresh alkaline cell at 1.5 V is below that. Two cells in series, or a supercapacitor charged above 1.8 V, are inside the start window, and after starting the input can fall to 0.5 V.
What is the real output current at 5 V? About 3 A from a 3.6 V input, which is the condition the 94.7 per cent efficiency figure is quoted at. A lower input gives less output current because the valley limit is on the switch, not on the load.
Is the load really disconnected when disabled? Yes. The part provides a true disconnect between input and output in shutdown, so neither side leaks into the other through the switches.
What happens when the input rises above the output? The converter stops switching and passes the input through with the high side switch on. The output then sits at the input minus the drop across that switch rather than at the regulated value.
Why is the switching frequency lower at low input? Because the control loop cannot hold a 1 MHz on time below about 1 V in, so the oscillator falls to 0.6 MHz to keep the switch controlled instead of skipping pulses.
What is the reel and moisture rating? 3000 pieces on a large reel at moisture level 2 with one year of floor life, so the reel needs baking only if it sits open beyond that.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Medical Device Components page sets out the checks that keep a substitute from failing on the bench.