TPS57040QDRCRQ1
Product Specifications
TPS57040QDRCRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS57040QDRCRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS57040QDRCRQ1: 0.5 A, 42 V automotive buck for 12 V and 24 V systems
TPS57040QDRCRQ1 is a step down regulator with the high side switch integrated in a VSON body of 10 pins. A 200 mOhm high side switch and a current mode controller in a 3 mm by 3 mm body, rated to 42 V and qualified to AEC-Q100 grade 1. The part covers 3.5 V to 42 V in, delivers 0.5 A, and runs from 100 kHz to 2.5 MHz with a resistor or an external clock.
Order code and package
| TPS57040QDRCRQ1 | active, production, VSON 10 pins, 3000 pieces on a large reel |
| Lead finish | NIPDAU, RoHS Yes |
| Moisture level | Level 3, 260 C, 168 hour floor life |
| Temperature | minus 40 to 125 C ambient, AEC-Q100 grade 1 |
| Sibling package | MSOP PowerPAD 10 pins with the same die |
| Marking and body | 3.00 mm by 3.00 mm, exposed pad on the underside |
Electrical parameters that decide the application
| Input voltage | 3.5 V to 42 V operating |
| Output current | 0.5 A |
| High side switch | 200 mOhm |
| Reference | 0.8 V internal |
| Switching frequency | 100 kHz to 2.5 MHz, synchronisable to an external clock |
| Quiescent current | 116 uA operating in pulse skip |
| Shutdown current | 1.5 uA with the enable pin low |
| Lockout | 2.5 V internal, adjustable through the enable pin |
| Power good | window between 92 and 109 per cent of nominal |
| Protection | cycle by cycle limit, frequency foldback, thermal shutdown |
Family variants and how they differ
| Eco-mode | pulse skipping at light load, which is where the 116 uA comes from |
| Slow start | the SS pin sets the ramp and can be used for tracking |
| Frequency | a resistor on RT/CLK, or an external clock for synchronisation |
| Enable divider | raises the lockout and adds hysteresis |
| Compensation | external on COMP, current mode |
| Bootstrap | 0.1 uF from BOOT to PH |
Points to check before this part goes on a BOM
A 42 V rating covers a 24 V system with margin and does not cover a 12 V load dump, which can reach 40 V or more for hundreds of milliseconds depending on the alternator and the clamp. The 42 V figure is also the absolute maximum, so a transient suppressor on the input is part of the circuit rather than an option.
The 0.5 A rating and the 200 mOhm switch set the loss budget. At 0.5 A the conduction loss is 50 mW, so the body stays cool and the thermal pad can be modest. The loss that matters at 12 V to 3.3 V is the switching loss, which scales with frequency and is why 2.5 MHz is only sensible at low input current.
Moisture level 3 with a 168 hour floor life is the practical difference from the MSOP sibling. Once the reel is opened the parts have to be reflowed within a week or baked, and a repair depot that keeps a partial reel on the shelf needs a dry cabinet.
The internal lockout of 2.5 V is far below the 3.5 V operating floor, so the enable divider is what actually protects a 12 V system from a cranking event. Set the divider to hold the part off below 6 V and the rail does not restart into a sagging battery.
Power good is open drain and reflects a window rather than a threshold. It asserts inside 92 to 109 per cent and releases outside, so a rail that sits at 90 per cent because of a load step reports a fault while still regulating every load on it.
Frequency foldback lowers the switching frequency during an overload. On a 42 V input that increases the on time and the peak current, so the inductor saturation rating has to cover the foldback point rather than the nominal ripple.
Eco-mode is a pulse skip scheme, so the output ripple at light load is larger and the switching frequency is not fixed. A rail that feeds an ADC reference should be forced into continuous conduction by loading it or by choosing a part without the skip mode.
12 V and 24 V systems in one build
The same order code covers both, because 42 V covers a 24 V rail with 18 V of margin and the current limit is set by the external components. What changes between the two is the inductor and the input capacitor voltage rating, not the part.
For a 24 V system the switching frequency is usually dropped to 300 to 500 kHz to keep the switching loss in check, and the inductor value rises with the lower frequency. The 0.5 A rating is unchanged.
Where the 0.5 A limit is visible
Half an amp is enough for a microcontroller, a CAN transceiver and a sensor cluster, and not enough for a display backlight or a fan. Builds that need more current in the same footprint move to a controller with external FETs rather than to a larger integrated part.
The limit also shows up at start up. A 100 uF output capacitor charged in 1 ms draws 100 mA on top of the load, which is inside the rating; charged in 100 us it draws 1 A and the current limit folds the frequency back.
Cold crank and the 3.5 V floor
A 12 V system that cranks drops to 6 V or lower for tens of milliseconds, and the 3.5 V floor on this part means the rail can stay in regulation through the event if the lockout divider is set below the lowest crank voltage. Setting it at 6 V protects the battery from a deep discharge and drops the rail at every start.
The choice is a system one. A module that must keep its memory alive through a crank sets the divider near 4 V and accepts a slower start, while a module that can restart after a crank sets it higher and uses power good to hold the processor in reset.
The other side of the crank event is the recovery. When the battery comes back the input rises fast, and the soft start capacitor decides whether the output ramps or steps. A 10 nF capacitor gives a ramp in the low milliseconds, which is slow enough to keep the inrush inside the current limit and fast enough that the processor is running again before the next cranking pulse arrives.
Where this order code fits
The part is bought for body control modules, instrument clusters and 24 V industrial supplies where the input can be dirty and the load is small. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
Can it take a 60 V transient? No. The absolute maximum is 42 V, so a load dump needs an external clamp. The 60 V transient figure belongs to the dual controller family, not to this part.
Does the 116 uA include the feedback divider? No. It is the supply current of the part in pulse skip with no load, and the divider across the output adds its own current on top, which is usually larger than the quiescent figure.
Why is the floor life only 168 hours? The body is moisture level 3. After 168 hours out of the sealed bag the parts have to be baked before reflow or the package can crack during the reflow cycle.
What sets the output voltage? A divider from the output to the 0.8 V reference on the feedback pin. The divider ratio also sets the loop gain, so the compensation changes when the output voltage changes.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the BOM Shortage Recovery page sets out the checks that keep a substitute from failing on the bench.