TPS56C215RNNR
Product Specifications
TPS56C215RNNR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS56C215RNNR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS56C215RNNR: 3.8 V to 17 V, 12 A synchronous buck in an 18 pin HotRod QFN
TPS56C215RNNR is a twelve amp monolithic buck with a D-CAP3 loop, an internal 4.7 V bias regulator and a mode pin that selects frequency, current limit and light load behaviour in a VQFN-HR body of 18 pins. It replaces a controller plus two external switches on a point of load rail, and the mode pin packs twelve operating combinations into one resistor divider.
Order code and package
| Order code | TPS56C215RNNR, RNN package, 3000 pieces on a large reel, level 2 moisture sensitivity |
| Body | VQFN-HR, 3.5 mm by 3.5 mm, 18 pins with a thermal pad |
| Control | D-CAP3 adaptive on time, no external compensation, ceramic output capacitors |
| Mode pin | Twelve states combining 400, 800 or 1200 kHz, two current limits and Eco-mode or forced continuous |
| Reference | 600 mV, 594 mV to 606 mV over the full junction range |
| Output range | 0.6 V to 5.5 V, set by two resistors |
Electrical parameters that decide the application
| Input range | 3.8 V to 17 V operating, 20 V absolute maximum, 4.5 V start-up without an external bias |
| Output current | 12 A continuous with the ILIM setting, 10 A with ILIM-1, valley limit 13.8 A and 11.5 A typical |
| High side switch | 7.8 mOhm typical at 25 C with a 4.7 V bias |
| Low side switch | 3.2 mOhm typical at 25 C |
| Switching frequency | 400 kHz, 800 kHz or 1200 kHz selected by the mode pin and latched at start-up |
| Minimum on time | 60 ns at 17 V in and 0.6 V out with 1200 kHz selected |
| Bias regulator | VREG5 4.7 V, 4.58 V to 4.83 V, current limit 100 mA to 200 mA |
| Soft start | 1.2 ms default, set by a capacitor on the SS pin |
| Quiescent current | 146 uA typical while not switching, 9.3 uA in shutdown |
| Protection | Valley current limit with hiccup, output over and under voltage, thermal shutdown, open drain power good |
Family variants and how they differ
| TPS568215 | the 8 A member of the same family and the same pin out, so a board can be built once and rated two ways |
| TPS56C230 | 12 A from 18 V in a 20 pin body with a 500 kHz fixed frequency and 17 mOhm switches |
| TPS562212 | 2 A from 18 V in an eight pin body, for a rail this part would be oversized for |
| TPS62130 | 3 A from 17 V in a 3 mm QFN with DCS control, a lower current alternative in a smaller body |
| TPS62410 | two 800 mA rails from 6 V, when the board needs two outputs rather than one large one |
Points to check before this part goes on a BOM
The mode pin is an analog input, not a logic pin. Twelve combinations of switching frequency, current limit and light load behaviour are selected by the voltage the pin sits at, and that voltage is read once at start-up and latched. A divider from VREG5 to ground sets it, so a wrong resistor pair does not disable the part, it silently selects the wrong frequency and current limit. Reading it back means a power cycle, not a register write.
The 60 ns minimum on time is the parameter that decides which rails this part can make. At 1200 kHz that is 7.2 per cent duty, so a 17 V input cannot regulate below 1.22 V and a 12 V input cannot go below 0.86 V. Dropping to 800 kHz halves the floor to 4.8 per cent, which allows 0.6 V from 12 V, and 400 kHz quarters it. High input, low output and the highest frequency cannot all be chosen together.
The two current limit settings are 11.5 A and 13.8 A typical valley, and the output current follows the valley plus half the ripple, which the data sheet states plainly. With 4 A of peak to peak ripple, which 400 kHz and a small inductor produce, the ILIM setting gives about 15.8 A of average before limiting and the ILIM-1 setting about 13.5 A. The 12 A and 10 A headline figures assume a ripple the board has to be built to deliver.
Twelve amps through a 3.5 mm package is a thermal statement. The low side switch at 3.2 mOhm carries 12 A for most of the period, which is 0.42 W, and the high side adds 0.09 W at a 12 V to 1 V ratio, so about half a watt leaves through the pad. The part is rated to 150 C junction rather than 125 C, which is what makes a 105 C ambient board possible, but the copper under the pad is still the limit and a two layer board will not hold 12 A for long.
VREG5 is a 4.7 V regulator with a 100 mA to 200 mA limit, and it can be driven from an external 5 V rail instead of from VIN. That overdrive is worth doing on a 12 V input because it removes the bias loss from the input, and it also changes what the under voltage lockout watches: the lockout monitors VREG5, not VIN, so an external bias can hold the part alive while the main input is below the 3.8 V threshold.
The start-up behaviour is worth separating from the operating range. The part starts at 4.5 V without an external 5 V bias but runs down to 3.8 V once started, and the lockout has enough hysteresis that a rail sagging through that window will not chatter. A 5 V rail at minus ten per cent is 4.5 V, right at the start-up threshold, so a board that must start on a low line needs the external bias or a lower frequency setting.
Power good is an open drain output that pulls low during soft start, during thermal shutdown and whenever the output leaves a window around 84 to 93 per cent on the way up and 108 to 116 per cent before it releases. It is not a supply voltage monitor and it is not a current limit flag, so a sequencer that waits for power good still has to watch the rail itself if a short is the failure it is protecting against.
The negative valley limit of 4 A allows the inductor current to reverse in forced continuous mode, which keeps the output from being pushed up by a back feed but also means the part can sink current into the low side switch. On a rail that can be driven by a second source, that behaviour is desirable and also a source of heat that a purely source-only budget will not predict.
Soft start defaults to 1.2 ms with the SS pin open and extends with a capacitor. The pin charges at about 6 uA, so a 10 nF part gives a ramp an order of magnitude slower, which is the usual way to keep inrush into a large output bank under the current limit. Because the same pin is the only soft start control, a build that changes the capacitor to fix an inrush problem also changes the rise time the sequencer was written against.
Where this order code fits
It belongs on the point of load rail of a server, a switch, a base station or an industrial controller, where a 12 V intermediate bus feeds a 1 V to 3.3 V core or memory rail at up to 12 A and the board has room for a 3.5 mm package with a solid ground plane. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
Can it make 0.6 V from 12 V at 12 A? Yes, at 800 kHz or 400 kHz. At 1200 kHz the 60 ns minimum on time sets a 0.86 V floor from a 12 V input, so the highest frequency is not available for that ratio.
How is the frequency set? By the DC voltage on the mode pin, which is read at start-up and latched. A resistor divider from VREG5 selects one of twelve combinations of frequency, current limit and light load mode.
What happens on a short? The valley current limit stops the cycle, the part enters hiccup and restarts, so the rail pulses rather than staying in constant current. The power good output pulls low during the event.
Is an external 5 V bias needed? No, but it improves efficiency and it moves the under voltage lockout to the VREG5 pin, which is useful when the main input is close to the 4.5 V start-up threshold.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the BOM Shortage Recovery page sets out the checks that keep a substitute from failing on the bench.