TPS563257DRLR
Product Specifications
TPS563257DRLR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS563257DRLR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS563257DRLR: 3 A buck converter in a 1.6 mm SOT-563 that stays in continuous conduction at light load
TPS563257DRLR is a 3 A synchronous step-down converter in the six pin DRL body that runs from 3 V to 17 V, holds 1.2 MHz in forced continuous conduction at any load and uses 55 milliohm and 24.3 milliohm integrated switches in a SOT-563 body of 6 pins. The TPS563257 is the forced continuous conduction member of the TPS56325x pair, with the Eco-mode TPS563252 alongside it. Input is 3 V to 17 V, output is 0.6 V to 10 V, the reference is 600 mV and the switching frequency is fixed at 1.2 MHz. The body is a six pin SOT-563 measuring 1.6 mm by 1.6 mm, with VIN, SW, GND, FB, EN and an open drain PG pin, so a complete 3 A rail occupies a square that is smaller than the inductor beside it.
Order code and package
| Order code | TPS563257DRLR |
| Input voltage | 3 V to 17 V |
| Output voltage | 0.6 V to 10 V |
| Rated output current | 3 A |
| Reference voltage | 600 mV, plus or minus 1 percent at 25 C |
| Switching frequency | 1.2 MHz |
| Package | six pin DRL SOT-563, 1.6 mm by 1.6 mm |
| Light load behaviour | forced continuous conduction |
| Sibling order code | TPS563252, Eco-mode at light load |
| Document | TPS56325x data sheet, revision A, May 2023 |
Electrical parameters that decide the application
| Input supply current, no load, non switching | 370 uA on the forced PWM version, 100 uA on the Eco-mode version |
| Shutdown current, EN low | 2 uA |
| Input UVLO, rising | 2.80 V to 3.00 V, 2.92 V typical |
| Input UVLO, falling | 2.60 V to 2.80 V, 2.72 V typical |
| High side switch resistance at 5 V or more | 55.0 milliohm, 67.5 milliohm at 3 V |
| Low side switch resistance at 5 V or more | 24.3 milliohm, 30.2 milliohm at 3 V |
| Minimum on time | 60 ns |
| Minimum off time | 110 ns |
| Maximum large duty operation | 95 percent |
| Enable threshold, rising | 1.15 V to 1.25 V, 1.19 V typical |
| Enable pull-down resistance | 2 Mohm |
| Valley overcurrent threshold | 3.1 A minimum, 4.1 A typical, 5.0 A maximum |
| Negative overcurrent threshold | 1.5 A to 2.5 A, 2.1 A typical |
| Internal soft start | 1.6 ms |
| Overvoltage trip | 115 percent typical, 24 us deglitch |
| Undervoltage trip | 60 percent typical, 220 us deglitch, 14 ms hiccup delay |
| Power good release, rising | 90 percent typical |
| Power good drop, falling | 85 percent typical |
| Thermal resistance, junction to ambient | 137.4 C per W JEDEC, 74 C per W on the EVM |
| Thermal shutdown | 155 C |
Points to check before this part goes on a BOM
The 137.4 C per W figure is a JEDEC board number and the 74 C per W figure is the same part on a two layer EVM with 2 oz copper at 12 V in and 5 V out. Conduction loss at 3 A is 9 times 55 milliohm in the high side switch and 9 times 24.3 milliohm in the low side, which is 0.50 W and 0.22 W before duty is applied, so a 12 V to 5 V rail carries about 0.33 W and rises 46 C on the JEDEC figure against 25 C on the EVM. A six pin SOT-563 has no exposed pad, so the drain and source leads are the heat path and the copper under them is the only thing that makes the difference.
The choice between this order code and the TPS563252 is a decision about light load, not about current. In forced continuous conduction the converter holds 1.2 MHz at any load, draws 370 uA with no load and keeps the output ripple at a switching frequency the rest of the board can filter. The Eco-mode part drops to 100 uA and skips pulses below a threshold, which is the right choice for a battery product and the wrong one for a rail that feeds a data converter or a radio, because the pulse skipping moves the ripple into the audio and intermediate bands where a filter was never placed.
The 60 ns minimum on time is the limit that catches high step-down ratios. At 1.2 MHz the period is 833 ns, so 60 ns is a 7.2 percent duty floor. Converting 17 V to 0.6 V needs 3.5 percent, which is 29 ns, and 17 V to 1 V needs 5.9 percent, which is 49 ns. Both are below the floor, so the converter has to skip cycles and the output ripple grows well beyond the continuous figure. From a 12 V bus the floor is reached at an output of 0.87 V, so the practical minimum output on a 12 V rail is around 1 V unless the input is reduced or the load is light enough to tolerate skipping.
The other duty limit is the 110 ns minimum off time, which caps the fixed frequency duty at roughly 87 percent. The 95 percent large duty operation that the feature list quotes is reached by letting the on time extend and the frequency fall, so a rail that has to survive a 12 V bus collapsing to 5.5 V does so by leaving continuous conduction behind. That is acceptable in a hold up event and it is not acceptable if the output feeds a synchronous load that expects a fixed clock.
The valley current limit acts on the low side switch, so it limits the bottom of the ripple rather than the top. The window is 3.1 A to 5.0 A with 4.1 A typical, and the negative threshold is 2.1 A typical, which is the level at which the converter stops sinking current into a pre biased output. The two together define a bidirectional window around the 3 A rating, and a load that pulls the output up, such as a back driven motor or a second supply on the same rail, is the case where the negative threshold is the term that trips first.
The undervoltage response is slow by switching standards: the trip is at 60 percent of the reference, the deglitch is 220 us and the hiccup restart is 14 ms. A short on the output therefore produces about thirty cycles of current limit, then a pause of 14 ms, then a retry, with an average dissipation far below the continuous number. That is a deliberate trade for a small package, and it means an upstream fuse sees a low average current rather than a hard fault, so a shorted rail can sit behind a resettable fuse indefinitely.
The enable pin has a 1.19 V threshold with 190 mV of hysteresis and a 2 Mohm pull-down, so a resistor divider from the input can set a precise turn-on point and the pin does not float up when the driving logic is unpowered. That matters on 12 V and 24 V buses where the logic rail comes up after the bus: the converter stays off until the divider, not a leakage path, decides it is time. The 2.92 V typical UVLO also means a 3.3 V bus at minus 10 percent is 297 mV above the rising threshold, which is enough for a cold start and not enough for a long ramp.
Where this order code fits
This order code belongs in industrial sensor nodes, 12 V and 24 V field equipment, gateways, motor control boards and instrumentation that need a quiet rail at light load as well as a full 3 A at peak. It is the part chosen when the converter has to run from a loosely regulated 12 V bus and the output has to stay in regulation through a 95 percent duty event, such as a 12 V rail sagging to 5.5 V during a supply dip. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
Why choose this part over the Eco-mode version? The two order codes share a package and a pin out, so the difference is entirely in light load behaviour. This one holds 1.2 MHz and 370 uA of supply current at no load; the Eco-mode version drops to 100 uA and skips pulses. If the rail feeds an analogue or radio stage where ripple frequency matters, the forced continuous part is the one to specify. If the product sleeps on a battery, the Eco-mode part wins on current and loses on ripple.
Can it make 0.6 V from a 17 V input? Not at 1.2 MHz in continuous conduction. A 0.6 V output from 17 V needs a 3.5 percent duty, which is 29 ns of on time against a 60 ns minimum. The converter will regulate the average but only by skipping cycles, so the ripple and the effective frequency change. From a 12 V input the same output needs 5 percent, which is 41 ns and still under the floor, so a 0.6 V rail belongs on a lower input or on a part with a shorter minimum on time.
What happens during a 12 V bus dip? The converter extends its on time and, above about 87 percent duty, lets the frequency fall to keep regulating. The feature list quotes 95 percent large duty operation, so a 5.5 V output from a 5.7 V input is inside the capability. What changes is the switching behaviour, which is no longer at a fixed 1.2 MHz, so a downstream filter tuned to that frequency sees a different spectrum for the duration of the dip.
Is the 3 A rating limited by thermals or by the current limit? By thermals in still air on a small board. The valley limit is 3.1 A minimum, which is above the 3 A rating, so the electrical path allows a little more. A 12 V to 5 V rail at 3 A dissipates about 0.33 W in the switches and rises 25 C on the EVM copper, which is comfortable at 25 C ambient and marginal at 85 C in a sealed enclosure, where the leads alone cannot move the heat.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the BOM Shortage Recovery page sets out the checks that keep a substitute from failing on the bench.