Contact Us

TPS548B28RWWR

Brand: Texas Instruments
Texas Instruments TPS548B28RWWR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS548B28RWWR — Power Management & Signal Chain | Superb Automation

TPS548B28RWWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS548B28RWWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS548B28RWWR: 20 A synchronous buck, 4 V to 16 V input, remote sense, VQFN-HR

TPS548B28RWWR is a 20 A synchronous step down converter with integrated 7.7 and 2.4 milliohm switches, differential remote sense and a programmable current limit, aimed at processor and accelerator core rails in a VQFN-HR body of 21 pins. The input range is 4 V to 16 V without an external bias and 2.7 V to 16 V with one, and the output covers 0.6 V to 5.5 V. The reference is 0.6 V at plus or minus 1 per cent over the full junction range, and the differential sense pair removes the drop in the copper between the converter and the load. Switching frequency is pin selectable at 600 kHz or 800 kHz, and the current limit is set by a resistor on the trip pin.

Order code and package

TPS548B28RWWRActive, VQFN-HR (RWW) body, 21 pins, 3000 pieces on a 180 mm reel, marking T548B8A
TPS548B28RWWR.AActive, same body and same 3000 piece reel, material row at MSL Level-2-260C-1YEAR
Reel options3000 pieces on a large reel for the R ending, 250 on a small reel for the T ending
Temperature rangeminus 40 to 125 degrees junction
Biasan external bias between 3.13 V and 3.6 V extends the input range down to 2.7 V

Electrical parameters that decide the application

Input voltage4 V to 16 V without bias, 2.7 V to 16 V with a 3.13 to 3.6 V bias
Output voltage0.6 V to 5.5 V
Output current20 A continuous
Switch resistance7.7 milliohm high side, 2.4 milliohm low side at 25 degrees
Switching frequencypin selectable at 600 kHz or 800 kHz
Reference0.6 V at plus or minus 1 per cent over minus 40 to 125 degrees
Current limitset by a resistor on the trip pin, with valley thresholds published against resistor values from about 5.2 kilohm to 20 kilohm
Quiescent currentabout 910 microamp on the input, 680 microamp on the internal LDO rail

Family variants and how they differ

TPS548B28the 20 A member, the string on this page
Bias optiona 3.3 V bias allows operation from a 2.7 V input, which is what a 3.3 V bus at the bottom of its tolerance looks like
Control modeD-CAP3 with an external reference input, so the output can track another rail
Light loadselectable forced continuous or auto skipping, set by a pin
Soft startprogrammable with an external capacitor rather than fixed internally

Points to check before this part goes on a BOM

Remote sense is the reason to use this part on a core rail. At 20 A a milliohm of copper is 20 mV, and a core rail at 0.9 V cannot afford to lose 20 mV between the converter and the load. The differential sense pair closes the loop at the load, so the voltage the processor sees is the voltage that is regulated. The pair has to be routed as a tight differential pair to the sense point at the load, or the loop regulates the wrong node.

Two point four milliohms on the low side is what makes 20 A possible without a heatsink. At 20 A and a 7.5 per cent duty cycle the low side carries most of the current and dissipates about 0.67 W, and the high side about 0.23 W. That is around 1 W in a 21 pin body, which requires the exposed pad and a serious copper area. A board that treats the pad as an afterthought reaches thermal foldback at half the rated current.

A programmable current limit is a margin tool and a procurement risk. The resistor on the trip pin sets the valley threshold, and the published table maps resistor values to thresholds from about 23 A down to 6 A. A board that changes the load without changing that resistor has the wrong protection, and a substitute part from another family with a different table produces a rail that trips early or not at all.

The 2.7 V input with a bias rail covers a 3.3 V bus at the bottom of its tolerance. Without the bias the input floor is 4 V, which excludes a 3.3 V rail entirely. With a 3.3 V bias the part works from 2.7 V, and that is the configuration used when a processor core rail is generated from the same 3.3 V rail that feeds its I/O. The bias pin is not optional in that case.

An external reference input allows tracking and margining. The internal 0.6 V reference can be overridden by a DC level on the reference pin, so the output can follow another rail at start up or be moved for a margin test. That is useful in a production test where the core rail has to be swept, and it is dangerous in the field if the pin is left floating on a long trace.

Pin selectable 600 or 800 kHz is a trade of size against loss. At 600 kHz the inductor is larger and the switching loss lower, which suits a 20 A rail in a server card where efficiency is the priority. At 800 kHz the inductor shrinks and the transient response improves, which suits a rail with a fast load step. Both settings are valid and the choice is made by the inductor that will fit.

Auto skipping at light load keeps a core rail efficient when the processor idles. At a few hundred milliamps the converter drops into a skip mode and the efficiency stays reasonable instead of collapsing. In forced continuous mode the ripple is constant and the light load efficiency is lower. A processor that idles most of the time benefits from the skipping mode and a rail that feeds an analog load does not.

Nine hundred microamps of quiescent current is a server number, not a battery number. A card in a rack has a permanent 12 V supply and the quiescent current is irrelevant. A portable product that sleeps on this rail would spend more on the converter than on the load, and there are members of the family with far lower quiescent current for that case.

The 21 pin body carries the whole 20 A path and has no pins to spare. Input capacitors have to sit directly against the input pins and the ground return has to be continuous under the part. A placement with the capacitors an inch away produces a switch node ring that shows up as radiated emissions and as voltage stress on the high side switch, and no amount of output filtering fixes it.

What to confirm before this part goes on a purchase order

State the input bus, the bias arrangement and the output current. The 2.7 V floor only exists with a bias rail, and the current limit resistor is chosen from the load current.

Say whether the output feeds a processor through copper. Remote sense is the feature that makes this part worthwhile and it only works if the sense pair reaches the load.

Where this order code fits

It makes a 0.9 V or 1.2 V core rail at 20 A for a processor, an FPGA or an accelerator card, with remote sense so the voltage at the load is the voltage that is regulated. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.

Questions buyers ask

Can it run from a 3.3 V bus? Only with a bias supply between 3.13 V and 3.6 V, which extends the input range down to 2.7 V. Without the bias the input floor is 4 V and a 3.3 V bus is out of range entirely.

What does the remote sense pair connect to? The output at the load, not at the converter. A differential pair from the sense pins to the point where the voltage has to be correct closes the loop there, and the copper drop between the converter and the load is compensated by a slightly higher converter output.

How is the current limit set? By a resistor from the trip pin to ground. The data sheet publishes a table of resistor values against valley current thresholds, and the value is chosen above the maximum load with margin for the inductor ripple. A resistor left out or left at the wrong value is the most common assembly error on this part.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Reduce Component Cost page sets out the checks that keep a substitute from failing on the bench.