The TPS54540BDDAR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS54540BDDAR: 42 V, 5 A step-down regulator with a 92 milliohm high side switch
TPS54540BDDAR is a 5 A step-down regulator with an integrated high side switch rated to 42 V in a HSOP body of 8 pins. It is a current mode converter with an external compensation network, a 100 kHz to 2.5 MHz adjustable frequency and an internal 4.3 V undervoltage lockout that can be raised through the enable pin. The device survives load dump pulses to 45 V under ISO 7637, which is why it turns up on vehicle rails and on 24 V industrial buses that see inductive switching.
Order code and package
| TPS54540DDAR | Active, HSOP-8 with PowerPAD, 2500 pieces on a large reel, MSL-2-260C-1 YEAR |
| TPS54540DDA | Active, the same body, 75 pieces in a tube |
| TPS54540DDARG4 | Active, Green material declaration, 2500 pieces on a large reel |
| The B suffix | the addendum in this document prints the plain TPS54540 rows only, no TPS54540B row appears |
| Temperature range | minus 40 to 150 degrees junction, but the addendum row prints minus 40 to 125 ambient |
Electrical parameters that decide the application
| Input voltage | 4.5 V to 42 V operating, load dump to 45 V |
| Continuous current | 5 A |
| High side switch | 92 milliohm |
| Reference | 0.8 V, plus or minus 1 per cent |
| Switching frequency | 100 kHz to 2.5 MHz, set by a resistor, or synchronised to an external clock |
| Quiescent current | 146 microamp in pulse skip, 2 microamp in shutdown |
| Undervoltage lockout | 4.3 V internal, adjustable upwards through the enable divider |
| Compensation | external, current mode control |
Family variants and how they differ
| TPS54540 | 5 A, 92 milliohm, the device this document covers |
| TPS54340 | the 3.5 A member with an 87 milliohm switch, same pinout family |
| TPS54341 | 3.5 A in a ten pin WSON with a power good output |
| RT/CLK pin | a resistor sets the frequency, pulling the pin above the upper threshold makes it a clock input |
| Package | eight terminal HSOP with the thermal pad on the underside |
Points to check before this part goes on a BOM
42 V input is not 42 V tolerant of everything. The operating range covers a 24 V bus with margin and survives a 45 V load dump for the duration stated in the standard. It does not survive a continuous 36 V rail with a 20 per cent transient, because that is 43 V and the part is already at its limit. The input capacitor voltage rating and the clamp have to be chosen with the same number in mind.
The 4.3 V lockout is a floor, not a setting. It is the point below which the part will not start, and it can only be raised with a divider on the enable pin. On a 5 V rail that leaves very little room, so a 5 V to 3.3 V application needs the divider calculated so the converter does not drop out during a supply sag. On a 12 V or 24 V rail the divider is what protects the converter from a slow brownout.
146 microamp in pulse skip is a real number at light load. The converter drops pulses to hold the output up, which keeps the no load input current low. The cost is ripple and a switching spectrum that moves with load. For a rail feeding a radio or an ADC, the pulse skip has to be accepted or the part has to be kept above the load where it stops skipping.
External compensation is work, and it is also freedom. Current mode control with an external network allows the crossover to be placed where the application needs it, which matters on a 5 A rail with a large output capacitance or a long cable. The alternative, an internally compensated part, is easier to use and cannot be tuned. A board that must pass a conducted emissions limit often needs the freedom.
The B suffix does not appear in this addendum. Every orderable row printed is a TPS54540DDA or DDAR string at 75 pieces in a tube or 2500 on a large reel. A catalogue line ending in BDDAR therefore cannot be confirmed from this document, and the reel size, the marking and the lifecycle status have to come from the vendor or from the actual offer. That is the first thing to settle before quoting.
Load dump survival is a system property, not a part property. The device survives 45 V pulses under ISO 7637 only if the input capacitor and any clamp in front of it are rated for the same event. A 50 V capacitor and a transient suppressor are usually part of the qualification, so the converter alone does not make a board automotive ready.
The thermal pad is the current path as well as the heat path. At 5 A the 92 milliohm switch dissipates 2.3 W during the on time, before switching loss. That heat leaves through the pad into the copper, and the pad also carries the ground return. A pad with insufficient vias heats the die and adds inductance in the return, which shows up as ringing on the switch node.
Two amps of margin over the load is the usual rule here. The 5 A rating is the switch current limit of the converter, and the inductor current peak sits above the DC output by half the ripple. At 5 A out with 30 per cent ripple the peak is 5.75 A, which is inside the limit, and at 6 A out it is not. The usable output current depends on the ripple, which depends on the inductor, which is the trade a 100 kHz to 2.5 MHz range exists to allow.
Current mode control needs a slope compensation check at high duty. Above about 50 per cent duty the inner current loop needs slope compensation to stay stable, and the amount depends on the inductor and the output voltage. A board copied from a 12 V to 5 V case to a 24 V to 20 V case keeps the same components but runs at a much higher duty, where the same inductor no longer leaves the loop with the same margin. The bench check is a load step at the highest input and the lowest output.
What to confirm on the offer for this string
The suffix, the reel size and the marking, because the B revision is not printed in the addendum that covers the plain part.
The thermal pad finish and the via pattern on the customer board, because a 2.3 W dissipation in this body is only manageable when the pad is soldered to a real copper area.
Where this order code fits
It powers 5 A loads on 12 V and 24 V industrial buses and on vehicle rails, where the input has to survive load dump pulses to 45 V. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
Can this part run from a 36 V rail continuously? The operating range is 4.5 V to 42 V, so 36 V is inside it. The margin to the absolute maximum is then small, and any transient above 42 V has to be clamped. A 36 V rail with a 20 per cent surge is outside the rating and needs a different converter.
Does it need an external diode? Yes, a catch diode is required. The device integrates the high side switch only. The diode carries the inductor current during the off time, so its forward drop is part of the efficiency, and a Schottky is the usual choice at these currents.
What sets the switching frequency? A resistor from the RT/CLK pin to ground, anywhere between 100 kHz and 2.5 MHz. Lower frequency favours efficiency and a larger inductor, higher frequency favours a smaller solution and more switching loss.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Pin to Pin Cross Reference page sets out the checks that keep a substitute from failing on the bench.