Contact Us

TPS54340BDDAR

Brand: Texas Instruments
Texas Instruments TPS54340BDDAR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS54340BDDAR — Power Management & Signal Chain | Superb Automation

TPS54340BDDAR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS54340BDDAR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS54340BDDAR: 42 V, 3.5 A step down converter with Eco-mode

TPS54340BDDAR is a nonsynchronous buck converter with the high side FET integrated and a diode outside in a HSOP body of 8 pins. It takes 4.5 V to 42 V in, delivers 3.5 A, and survives the load dump pulses that a 24 V vehicle bus produces.

Order code and package

Order codeTPS54340BDDAR, DDA package, 75 pieces per tube
BodyHSOP with PowerPAD, 4.89 mm by 3.90 mm, eight terminals
Switch92 mOhm high side FET, external catch diode
Frequency100 kHz to 2.5 MHz set by a resistor, or synchronised to an external clock
Reference0.8 V at 1 per cent

Electrical parameters that decide the application

Input range4.5 V to 42 V operating, 45 V absolute maximum
Output current3.5 A continuous, 4.5 A minimum peak inductor current limit
Quiescent current146 uA operating in Eco-mode, 1 uA in shutdown
Undervoltage lockout4.3 V internal, adjustable upward with the enable divider
Light loadPulse skipping with an integrated boot recharge FET
ProtectionCycle by cycle current limit, thermal shutdown, overvoltage and frequency foldback
Temperature-40 C to 150 C junction, wider than most parts in this band

Family variants and how they differ

TPS54340The original release, this B revision changes the current limit and the boot recharge behaviour
RT/CLK pinA resistor sets the frequency, or an external clock between 100 kHz and 2.5 MHz drives it
EN pinA divider sets a UVLO threshold above the internal 4.3 V, with hysteresis from the pin current
BOOTIntegrated recharge FET, so a very low dropout is possible at light load
Eco-modePulse skipping at light load, which is what makes the 146 uA figure meaningful

Points to check before this part goes on a BOM

The catch diode is outside the part and it is the dominant loss at low duty cycle. At 24 V to 5 V the diode carries 3.5 A for 79 per cent of the period, so a 0.5 V Schottky dissipates 1.4 W against 0.21 W in the 92 mOhm high side FET. That is why this part is for 3.5 A and not for 10 A, and why a synchronous converter is the right choice above a few amps.

The 4.5 A peak inductor current limit is the number the inductor is chosen against, not the 3.5 A output. With 30 per cent ripple at 3.5 A the peak is 4.0 A, which leaves 0.5 A of margin, and a transient that pushes the peak past 4.5 A trips the cycle by cycle limit and the output sags rather than the switch failing.

The 45 V absolute maximum is a load dump specification per ISO 7637, not a continuous rating. A 24 V vehicle bus can reach 40 V in normal operation during a jump start, and the part survives that, but a suppressed load dump that clamps at 42 V sits at the operating limit with no margin for the switching overshoot on the SW node.

Eco-mode pulse skipping is what makes the 146 uA quiescent figure usable. At a few hundred microamps of load the part stops switching for long periods, and 146 uA over a year is 1.28 Ah, which is small compared with what a standby rail is allowed to take. In continuous conduction the same part draws several milliamps and the standby budget changes completely.

The integrated boot recharge FET allows a very low dropout at light load, because the high side FET can be held on for long periods without the bootstrap capacitor running down. At 3.5 A the dropout is the FET resistance plus the inductor resistance, and a 5 V rail from a 5.5 V input is inside the part while a 5 V rail from a 5.2 V input is not.

Frequency foldback is the protection that saves the inductor during a short. When the output collapses the part reduces the switching frequency, which lengthens the off time and stops the current from ratcheting up cycle by cycle. A part without foldback needs a much larger inductor to survive the same fault.

The adjustable UVLO through the enable divider is how a 12 V rail is held off until it is valid. The pin has no voltage hysteresis of its own, so the divider has to supply a hysteresis current, and a board that copies a divider from a part with internal hysteresis gets a rail that chatters at the threshold.

The HSOP body with a PowerPAD is a 150 C part, and the pad is the only heat path. At 3.5 A and 1.4 W of diode loss plus switch loss, the copper under the pad is as much a part of the thermal answer as the package, and a board that leaves the pad unconnected derates the part to a fraction of its rating.

At the top of the frequency range the on time becomes the limit. A 42 V to 5 V conversion at 2.5 MHz needs 47 ns of on time, which is close to the minimum the part can produce, and at 42 V to 3.3 V it needs 31 ns and cannot be done at all. The high end of the range is for 12 V inputs and small inductors, not for a 42 V bus.

The integrated boot recharge FET allows the high side device to stay on for many cycles at light load, which is how the part reaches a very low dropout. The catch is that the boot capacitor is recharged only when the SW node is low, so a converter held at 100 per cent duty for a long time depends on that internal FET rather than on the switching waveform, and a part without it would drop out.

Eco-mode ripple at light load is larger than the datasheet curves suggest when the output capacitor is small. With 22 uF and a 1 mA load the part can deliver a burst of pulses and then wait, so the rail moves by tens of millivolts at a few hundred hertz. A load that measures its own supply, such as an ADC reference, sees that as noise and needs either a larger capacitor or a continuous conduction part.

Where this order code fits

The part suits a 12 V or 24 V industrial or automotive rail that has to produce 5 V or 3.3 V at a few amps, especially where the input can spike and the board cannot afford a synchronous converter. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.

Questions buyers ask

Does it need an external diode? Yes, a Schottky from SW to ground. The part is nonsynchronous and the diode carries the inductor current for most of the period.

Can it run at 2.5 MHz? Yes, the RT resistor sets it, but 2.5 MHz at 42 V input is a very short on time and the efficiency falls sharply. The high end is for small solution size, not for efficiency.

What is the Eco-mode trade off? Ripple and frequency vary with load at light currents, which is acceptable for a digital rail and not for an analog one.

Is the 45 V figure continuous? No, it is an absolute maximum for transients. Continuous operation stops at 42 V.

Can two of these be synchronised? Yes, the RT/CLK pin accepts an external clock between 100 kHz and 2.5 MHz, so several converters can share a frequency and avoid beating against each other.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.