TPS54227DDAR
Product Specifications
TPS54227DDAR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS54227DDAR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS54227DDAR: 4.5 V to 18 V input, 2 A synchronous buck with D-CAP2 control
TPS54227DDAR is a synchronous step-down converter with integrated switches and an internal compensation scheme in a SO PowerPAD body of 8 pins. It takes 4.5 V to 18 V in, holds any output from 0.76 V to 7 V at up to 2 A, switches at a pseudo-fixed 700 kHz, and needs no external compensation because the loop is set inside the part.
Order code and package
| Ordering string | TPS54227DDAR, DDA package, SO PowerPAD, tape and reel |
| Package | 8-pin SO PowerPAD, exposed pad on the underside |
| Ambient range | -40 C to 85 C |
| Pin count check | VIN, SW, VFB, VREG5, VBST, EN, SS and GND |
| Output setpoint | 0.76 V to 7 V by a divider on VFB, reference 0.765 V |
Electrical parameters that decide the application
| Input range | 4.5 V to 18 V |
| Current | 2 A continuous, current limit 2.5 A minimum, 3.3 A typical, 4.7 A maximum |
| Switch resistance | 155 milliohm high side in DDA, 108 milliohm low side at 25 C |
| Switching frequency | 700 kHz pseudo-fixed, 650 kHz in continuous conduction |
| Shutdown current | 5 microamp typical, 10 microamp maximum |
| Soft start | External capacitor on SS, 2 microamp source current |
| Prebiased start | Allowed, so the output is not pulled down at start-up |
Points to check before this part goes on a BOM
Conduction loss at the rated current is modest but not zero: at 2 A, 155 milliohm on the high side for 5.8 percent of the period and 108 milliohm on the low side for the rest comes to 0.44 W, which the 8-pin PowerPAD has to pass into the board. The pad is the only path, so a footprint without copper underneath turns a 2 A converter into a 1 A converter without any change to the circuit or the bill of materials.
The 2 A rating and the 2.5 A minimum current limit leave only 25 percent between the load and the trip point, and the inductor ripple sits on top of the DC current. At 12 V in, 1.05 V out, 2.2 microhenry and 700 kHz the ripple is about 0.65 A peak to peak, so a 2 A load peaks at 2.33 A and the margin to the minimum limit is 170 mA, not 500 mA.
An 18 V input with a 1.05 V output is a 5.8 percent duty cycle, which at 700 kHz is an 83 ns on time. D-CAP2 handles that, but the on time is short enough that the high-side gate drive and the switch node capacitance become a real share of the loss, and the efficiency curve at 18 V in will be several points below the same converter fed from 12 V.
The soft-start time is set by a capacitor and the 2 microamp source current using the expression in the data sheet, so 10 nF gives about 4.2 ms. That number has to be larger than the time the upstream rail takes to come up, otherwise the converter finishes soft start while its input is still rising and the output overshoots through the feedback divider.
Standby current of 5 microamp typical and 10 microamp maximum is 43.8 mAh to 87.6 mAh over a year, which is small for a mains product and large for a battery one. On a battery rail the enable pin should be driven from the system state machine rather than tied to VIN, because a converter that is enabled draws its quiescent current whether or not the load needs it.
D-CAP2 tolerates ceramic output capacitors because the loop does not depend on a minimum ESR, but it does depend on the output capacitance value and its ESR for the load-step response. Substituting a smaller case size with the same microfarad reading changes the transient result, and the data sheet's transient plots were taken with the reference values, not with the smallest part that fits the pad.
The same converter is listed with two high-side resistances, 155 milliohm in the DDA body and 165 milliohm in the DRC body, so the ordering suffix changes the conduction loss at 2 A by about 0.04 W. That is small on its own and it decides which of the two footprints a board can carry, because the bodies are not interchangeable and the pad geometry differs between them.
Where this order code fits
The typical fit is a 12 V or 18 V rail feeding a 1.2 V, 1.8 V, 3.3 V or 5 V digital or analog load between about 0.5 A and 2 A, in equipment where an external compensation network is one more thing that can be wrong. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.
Questions buyers ask
Can I set 0.9 V with one percent resistors? Yes. The reference is 0.765 V, so the divider ratio is about 1.18 and one percent parts put the output within about 15 mV of the target before the reference tolerance is counted.
Why does the part run at two different frequencies? The one-shot timer gives a pseudo-fixed 700 kHz in discontinuous operation and the converter holds about 650 kHz in continuous conduction. Both numbers describe the same part under different loads, so an inductor chosen from one and a capacitor from the other is a common source of confusion.
What happens on a shorted output? The current limit trips between 2.5 A and 4.7 A and the part hiccups until the short clears. The wide spread is the reason a load that must survive a 2.6 A surge cannot rely on this converter to pass it.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Reduce Component Cost page sets out the checks that keep a substitute from failing on the bench.