Contact Us

TPS4H160BQPWPRQ1

Brand: Texas Instruments
Texas Instruments TPS4H160BQPWPRQ1 is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS4H160BQPWPRQ1 — Power Management & Signal Chain | Superb Automation

TPS4H160BQPWPRQ1

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS4H160BQPWPRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS4H160BQPWPRQ1: quad channel 40 V automotive high side switch with analog current sense

TPS4H160BQPWPRQ1 is a four channel smart high side switch with 160 mOhm NMOS power FETs, full diagnostics and an analog current sense output on each channel in a HTSSOP body of 28 pins. It works from 3.4 V to 40 V, carries AEC-Q100 grade 1 qualification over -40 C to 125 C ambient, and reports load current as an analog voltage that the module controller can read without a shunt. The current limit is set by one external resistor, and the whole device draws under 500 nA in standby.

Order code and package

TPS4H160BQPWPRQ128-pin HTSSOP (PWP) with exposed pad, large reel, version B with analog current sense
TPS4H160AQPWPRQ1same body and channels, version A with open-drain fault output instead of analog sense
Channel countfour channels, OUT1 and OUT2 on two pins each, OUT3 and OUT4 on one pin each
QualificationAEC-Q100 grade 1, HBM class H3A, CDM class C4B, functional safety capable
Ambient temperature-40 C to 125 C, junction limited by the thermal pad

Electrical parameters that decide the application

Supply voltage, operating3.4 V to 40 V
On resistance per channel160 mOhm NMOS, quoted at 13.5 V supply
Standby currentunder 500 nA with the part disabled
Current sense accuracyplus or minus 15 per cent above 25 mA load, 8 per cent above 0.5 A
Internal current limit threshold0.8 V typical across the sense resistor path
External current limit accuracyplus or minus 15 per cent above 500 mA load
Output current linear range0 A to 2.5 A with the sense voltage below 4 V
Turn on delay20 us minimum, 50 us typical, 90 us maximum
Output slew rate0.1 V/us to 0.55 V/us, 0.3 V/us typical
Reverse diode drop0.7 V typical, 0.9 V maximum at 150 mA reverse

Diagnostics the part reports

Overcurrent and short to grounddetected per channel and clamped at the set limit, internal or external
Open loaddetected while the channel is on, reported through the fault path
Short to batterydetected while the channel is off, so a fault is known before the load is energised
Global fault reportone pin interrupts the controller for any channel, the detail is read from the sense path
Thermal shutdownwith a latch off option and a thermal swing mode that retries after cooling
Loss of ground or loss of batterythe channel stays defined, the part does not turn a load on by accident
Inductive load clampthe negative voltage from a switched inductive load is clamped inside the part

Points to check before this part goes on a BOM

The 160 mOhm figure is per channel and it is quoted at 13.5 V with the FET fully enhanced. At 2 A per channel the conduction loss is 0.64 W per channel, so four channels at full load dissipate 2.5 W in a 28-pin HTSSOP. That number, not the current rating, decides how many channels a module can run at once, and the exposed pad is the only path for that heat.

The analog sense output is a voltage proportional to load current with a fixed ratio, so the module reads current without a shunt and without the loss of a shunt. The accuracy is quoted as plus or minus 15 per cent above 25 mA and 8 per cent above 0.5 A, which means the same channel that is good enough for a lamp or a relay coil at low current is not good enough to measure a small actuator current near zero. A control loop that needs milliamps of resolution at low load needs a shunt.

The output current linear range ends at 2.5 A, with the sense voltage kept below 4 V. Above that the sense output saturates and the reported current stops tracking. A channel set for a 3 A load therefore reports correctly up to the top of the linear range and then flattens, which looks like a load that has stopped drawing current unless the controller knows the ceiling.

The external current limit is set by a resistor and is accurate to plus or minus 15 per cent above 500 mA. That tolerance is what decides the fuse and the wire gauge behind the channel, because the load can reach the upper end of the window before the part acts. A 1 A limit with a 15 per cent window means the harness has to carry 1.15 A continuously without heating, and the connector rating should be read the same way.

The thermal shutdown has two behaviours and the order code does not select between them, the mode is set by how the channel is driven. In latch off mode the channel stays off after the junction cools and needs a command to restart, which is what a safety function usually wants. In thermal swing mode the channel retries on its own, which suits a load that is allowed to cycle, such as a heated seat or a lamp that is dimmed by pulse width.

Open load detection on a channel that is on relies on a small current through the load and a comparison across the switch. A load with a large capacitor in parallel, or an LED string with a series capacitor, holds the node up and hides the open circuit until the channel is switched. On a body control module that monitors lamps, this is the reason the diagnostic runs at the edge of the switching cycle rather than continuously.

Short to battery detection runs while the channel is off, which is the state that matters for a load that should not be energised. A module that wakes up and checks all four channels before turning anything on can report a harness fault before the load is switched, and that ordering of the checks is what keeps a stuck output from being commanded on into a short.

The inductive clamp is inside the part, so a relay coil or a small motor does not need an external diode. The clamp voltage is set high enough to demagnetise the load quickly and low enough to stay inside the 40 V rating, and the slew rate setting decides how fast the channel turns off. A slow slew rate lowers the radiated emission from the harness and increases the time the FET spends in the linear region, which is heat, so the two settings are traded on the bench.

Loss of ground is the fault that kills high side switches, because the load current finds a path back through the module ground and the control pins. This part is specified to survive that condition with the channel state defined rather than following the load. That protection is a specification, not a guess, and it is the first item to confirm when a module is qualified against a load dump and a ground offset test.

The 28-pin body carries four channels on the same pad, so the thermal calculation is not per channel. A module that uses two channels at 2 A and two at 100 mA has an uneven temperature distribution across the pad, and the die temperature is set by the hottest spot. Splitting a load across channels to spread the heat only helps when the channels are driven with the same duty cycle, and interleaving the pulse widths does not reduce the total dissipation.

Version A and version B share the body, the pin count and most of the specification. Version A gives an open-drain fault flag per channel, version B gives an analog current output. A module built for version A that is reworked with version B will not report faults at all, because the pin that carried the flag now carries a voltage, and the controller reads it as a constant. The two order codes have to be kept apart in the bill of materials and in the rework instruction.

The qualification is grade 1 over -40 C to 125 C ambient, and the parts are functional safety capable with documentation available to support a safety case. That documentation is a separate request to the vendor, not something in the datasheet, and it is needed before the part can be used in a system with an ASIL target. A program that plans to claim functional safety should order the documents with the first prototype, not with the production release.

Why the pad decides the channel count

The package dissipates through the exposed pad into the copper under the body, and the thermal resistance from junction to that pad is the number that limits the module. A four channel part with two channels at high current is not running at half the dissipation of four channels at the same current, because the channels share the die and the hottest channel sets the shutdown. The pad geometry in the vendor drawing, including the via pattern, is the only thing that changes the result.

Where this order code fits

It sits between the 12 V vehicle rail and the loads in an ADAS sensor module, a display module or a body controller, where four outputs have to be switched independently and each one has to be able to say whether it is open, shorted or drawing too much current. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.

Questions buyers ask

Is this the analog sense version? Yes. The B in the order code is the analog current sense output, the A version is the open-drain fault flag. Both are the same four channel 160 mOhm switch in the same 28-pin package, and the electrical ratings are common apart from the diagnostic path.

How is the current limit set? With one external resistor, which sets the threshold against the internal 0.8 V reference. The accuracy is plus or minus 15 per cent above 500 mA of load, so the harness and the connector have to be rated for the upper end of that window rather than for the nominal limit.

Can it drive a motor directly? It can switch a small brushed motor and it clamps the inductive kick internally, but it is a high side switch, not an H bridge, so it turns one side of the load on and off against ground. A motor that has to reverse needs a bridge, and the four channels here are independent switches, not a bridge.

What does the part do if the ground is lost? The channel state stays defined and the part does not turn a load on because the ground reference has moved. That behaviour is specified rather than incidental, and it is the item to confirm on the bench during a ground offset test before the module is released.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.