TPS3851H30EQDRBRQ1
Product Specifications
TPS3851H30EQDRBRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS3851H30EQDRBRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS3851H30EQDRBRQ1 automotive supervisor with a 2.79 V threshold and wettable flanks
The TPS3851H30EQDRBRQ1 is the automotive qualified member of the TPS3851 family, a precision supervisor with an integrated watchdog in the 8 pin VSON body with wettable flanks. The H30 field sets a 7 % undervoltage window on a 3.0 V rail, which puts the falling threshold at 2.79 V, and the Q1 suffix is the AEC-Q100 grade 1 qualification.
The wettable flank detail is the one that matters on the line rather than on the bench. A VSON with plain cut edges cannot be inspected by automated optical inspection after reflow, and the flank plating gives the solder joint a visible fillet on all four sides. On an automotive board that is the difference between a process that can be inspected and one that has to be x-rayed.
Key parameters taken from the SBVS286B document
| Qualification | AEC-Q100 grade 1, minus 40 to plus 125 degrees ambient, HBM level 2 and CDM level C4B |
| Functional safety | Documentation available to support a functional safety system, which the vendor lists as a capability of the part |
| Supply range | 1.6 V to 6.5 V on VDD |
| Falling threshold | 2.79 V, which is 7 % below the 3.0 V nominal, held to plus or minus 0.8 % over the full range |
| Hysteresis | 0.5 % typical, so the release point is roughly 2.81 V and the rail has to recover 20 mV |
| Supply current | 10 microamp typical, the same as the industrial member |
| Reset delay | 200 ms nominal, 170 to 230 ms, fixed |
| Watchdog default | 1600 ms with CWD open and SET1 high, and 200 ms with a 10 kOhm resistor from CWD to VDD |
| Watchdog disable | SET1 low, and WDO only asserts while RESET is high |
| Manual reset | MR pin with a 620 nA internal pull-up current |
| Body | VSON 8 pin, 3.00 mm by 3.00 mm, with wettable flanks for optical inspection |
| Order row | 3000 pieces on a large reel, NIPDAU, moisture level 2 at 260 degrees with a one year floor life |
The H option against a 3.0 V rail in a vehicle
A 3.0 V rail in an automotive module is usually a downstream regulator output, not the battery. It sees cold crank dips, load dumps through the upstream converter and the thermal cycling of an engine bay or a door module. The H option at 2.79 V is chosen there because a 5 % rail tolerance plus a 0.8 % threshold window plus the regulator dropout leaves less than the G option needs.
The trade is that a 2.79 V trip sits only 210 mV below nominal. Any load step that pulls the rail down by 200 mV will assert reset, and the watchdog and the reset chain then interact: a supply dip produces a reset, the reset clears the code, the code has to reinitialise, and if the dip repeats the module spends its time booting. That is why the H option is paired in practice with a bulk capacitor sized for the load step rather than for the average current.
The 0.8 % accuracy over temperature is what makes the narrow margin workable. On a part with 2 % accuracy the same 210 mV would be consumed by the threshold window alone, and the margin would disappear between minus 40 and plus 125 degrees.
Wettable flanks, moisture level and the reel
The order row for this part carries moisture level 2 at 260 degrees with a one year floor life, which is one level stricter than the industrial member of the same family. A part at level 2 has to be used within a year of the bag opening or baked before use, and a line that treats every VSON as level 1 will eventually run a wet reel.
| Package | SON DRB 8 pin with wettable flanks, 3.00 mm by 3.00 mm |
| Moisture level | Level 2 at 260 degrees, one year floor life, so the bag date code is part of the incoming record |
| Lead finish | NIPDAU on the published row, with a tin option listed on the duplicate rows of the same string |
| Part marking | 851NF, which separates this automotive part from the 851FD marking on the industrial G30 member |
| Reel | 3000 pieces on a large reel for every H30 row in the addendum |
| Sibling rows | H18, H25 and H30 exist in E and S timing variants, all on the same body and reel size |
The marking code is the practical check. A mixed carton of industrial and automotive parts is not distinguishable by appearance, and the 851NF against 851FD is the only visible difference on the body.
Where the automotive member is used
- Surround view and camera ECUs, where the image processor has to be recovered from a hang without losing the frame buffer
- Occupant detection sensors and seat modules with a 3.0 V logic rail
- Body control modules that need a watchdog inside the safety path rather than in the application code
- Gateway and infotainment boards where a supply event and a software event must be logged separately
- Any module where the reset must be visible to optical inspection after reflow
The two applications the vendor prints are the surround view ECU and the occupant detection sensor, and both share the same reason: a camera or a sensor that stops responding has to be reset by hardware, because the software that would notice is the software that stopped.
Order code, marking and reel
| TPS3851H30EQDRBRQ1 | Active, production, SON DRB 8 pin, 3000 pieces on a large reel, marking 851NF |
| Timing options | E is the 77.4 ms per nF window and S is the 3.23 ms per nF window, both published for this part |
| Industrial equivalent | TPS3851H30EDRBR without the Q1 suffix, same threshold and same body without the wettable flank requirement |
| Qualification paper | The AEC-Q100 grade 1 result and the HBM and CDM levels are printed in the document header, and a customer audit usually asks for both |
Sourcing notes for this line
Automotive qualified supervisors are one of the few categories where a substitution has to be argued through the customer's qualification rather than through a datasheet comparison, because the part sits inside a safety path and the change costs a re-test. The power management cross reference lists the equivalents by threshold and package and states which of them carry an automotive grade.
The characteristic failure on this class is a counterfeit or a re-marked industrial part sold as Q1. The tell is the marking code and the moisture label, not the datasheet, so the incoming check is a visual one. The incoming inspection plan page sets out the steps for parts of this class, including the bag date code and the reel label.
For a programme with a ten year service life, the automotive grade is also the part that stays available longest, because the vendor commits to the qualification. The last time buy and long life planning page covers how that commitment is read against a lifecycle notice.
Questions buyers ask about this part
Is the H30 a drop in for the G30? In footprint and pinout yes. In behaviour no, because the threshold moves from 2.88 V to 2.79 V and a 3.0 V rail that was marginal becomes comfortable.
Does the automotive part need a different decoupling? No. The recommended capacitor on VDD is the same, and the change is in qualification and in inspection, not in the application circuit.
Can the watchdog be left disabled in a production module? It can, through SET1, but a module qualified without the watchdog active has to be re-qualified if it is enabled later.