TPS3840PL20DBVR
Product Specifications
TPS3840PL20DBVR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS3840PL20DBVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS3840PL20DBVR nano power supervisor with a 2.0 V threshold and a push-pull reset
The TPS3840PL20DBVR is a single channel supply supervisor in the 5 pin SOT-23 body with a fixed 2.0 V falling threshold, a push-pull active-low reset output and a supply current of 300 nA typical. It holds a processor, a radio module or a memory device in reset while the rail sits below 2.0 V and releases the line after a delay the user sets with one capacitor on the CT pin.
The PL suffix is the reason this member gets picked on a dense board. The output both sources and sinks current, so it drives an enable pin, a shutdown pin or a load switch gate without a pull-up resistor and without a second component in the reset path. The DL member of the same silicon is the open-drain version, and the PH member is the active-high mirror, so the three are interchangeable in footprint alone and not in behaviour.
Key parameters taken from the SNVSB03E document
| Supply range | 1.5 V to 10 V on VDD, so a 9 V rail is monitored with no external divider and a 24 V rail with two resistors |
| Falling threshold | 2.0 V nominal, with 1 % typical and 1.5 % maximum accuracy over minus 40 to plus 125 degrees |
| Hysteresis | 100 mV typical for any threshold between 1.6 V and 3.0 V, which puts the release point at 2.1 V and stops the output chattering on a slow ramp |
| Supply current | 300 nA typical and 700 nA maximum, so the supervisor does not drain a coin cell |
| Output | Push-pull active-low, 0.8 times VDD minimum high level at 2 mA of source current, 200 mV maximum low level at 2 mA of sink current |
| Start-up delay | 220 microseconds typical and 350 microseconds maximum with the CT pin open |
| Reset delay | 50 microseconds with CT open, 6.2 ms with 10 nF, 619 ms with 1 microfarad and 6.2 s at the 10 microfarad ceiling |
| CT pin resistance | 500 kOhm typical, printed as a 350 to 650 kOhm window, which is the term that turns the capacitor into a time |
| Manual reset | MR pin with a 600 mV maximum low threshold, 0.7 times VDD minimum high threshold and a 100 kOhm internal pull-up |
| Propagation | 15 microseconds typical and 30 microseconds maximum from the trip point to the output |
| Glitch immunity | 10 microseconds at a 5 % overdrive, which is what keeps a load transient from being read as a supply fault |
| Power-on reset | Output state defined from 300 mV of VDD, so the enable line is held off during a slow ramp instead of floating |
| Body | SOT-23 5 pin, 2.90 mm by 1.60 mm nominal |
Why 2.0 V is the useful threshold on a two cell alkaline product
A pair of alkaline cells reads 3.0 V fresh, 2.4 V through most of its working life and falls away quickly below 2.0 V. A 2.0 V supervisor is therefore the end of life marker rather than a brownout detector, and the job it does is different. It stops the controller from writing flash on a rail that is already collapsing, and it parks the load switch before the boost converter starts to oscillate.
Two numbers decide whether the margin is enough. The first is the 1.5 % threshold window, which on a 2.0 V trip point is plus or minus 30 mV, so the worst case trip sits at 1.97 V. The second is the 100 mV of hysteresis, which means the release point is 2.10 V and the rail has to recover 100 mV before the processor is let go. A circuit that expects a 2.0 V trip and a 2.0 V release has not read that row.
Setting the reset delay with one capacitor on CT
The delay is the time the CT pin takes to charge through an internal 500 kOhm resistor to the internal threshold, so it scales with the capacitor almost linearly above a few nanofarads. The published points are enough to size most boards without a curve: 10 nF gives 6.2 ms, 1 microfarad gives 619 ms and 10 microfarad is the ceiling at 6.2 s, because the data sheet stops there and larger values are not characterised.
| CT open | 50 microseconds, which is the setting to use when the reset only has to be long enough to be seen |
| CT 10 nF | 6.2 ms typical, a common choice for a sensor node that has to survive a rail dip |
| CT 1 microfarad | 619 ms typical, the value used when a flash write must finish before the next boot attempt |
| CT 10 microfarad | 6.2 s, the top of the characterised range and the point at which a low leakage capacitor matters |
| Capacitor type | A ceramic part is what the vendor recommends, because leakage current adds to the charge time and makes the delay longer than calculated |
The start-up delay is separate from the CT delay. A rail that crosses the threshold has to stay above it for 220 microseconds before the output is released, and a capacitor on CT adds to that first event too.
Where the PL20 belongs on the board
The applications the vendor lists are grid infrastructure such as circuit breakers and smart meters, factory automation such as field transmitters and PLC cards, building automation such as fire panels, smoke detectors and HVAC controllers, point of sale terminals and portable battery powered systems. The common thread is a rail between 1.5 V and 10 V that has to be watched by something drawing less than a microamp.
- Two cell alkaline instruments that need a clean shutdown at end of life rather than a brownout crash
- Battery backed meters and data loggers where the supervisor runs from the cells and not from a regulated rail
- Radio modules that must be held off until the supply has passed 2.1 V and the reference has settled
- Load switch and boost converter enable lines, where a push-pull output removes the pull-up and its leakage
- Boards that need a manual reset button without a second part, using the MR pin
Order code, marking and reel
| TPS3840PL20DBVR | Active, production, SOT-23 DBV 5 pin, 3000 pieces on a large reel |
| Lead finish and moisture | NIPDAU, moisture level 1 at 260 degrees with unlimited floor life, so no bake is needed after a long store |
| Temperature | Minus 40 to plus 125 degrees on every published row |
| Part marking | PL18 on the body, which is one code below the 2.0 V threshold option, so a marking check against the datasheet table is the only way to confirm the trip point on a received reel |
| Related members | TPS3840DL20DBVR for the open-drain output and TPS3840PH20 for the active-high output, same body and same pinout |
Sourcing notes for this line
A 2.0 V supervisor in a 5 pin SOT-23 is a commodity part with long lead times whenever the analog fabs are full, and the substitutes on the market are rarely pin compatible on both the threshold and the output topology. The useful comparison is against the power management cross reference, which lists the parts that share the pinout and states which of them differ in hysteresis or in delay behaviour.
Where a customer needs a 2.0 V trip and the exact order code is on allocation, the two lever points are the open-drain member of the same family and the wider tolerance grade from a second vendor. Both are covered on the pin to pin cross reference page, and both need the hysteresis and the release point checked before a line is released, because a 100 mV release against a 40 mV release changes the behaviour of the whole reset chain.
For volume programmes the reel size and the moisture level decide whether a part can go straight to the line. The 3000 piece large reel at level 1 is the simplest case. Where a re-reel or a cut tape is offered instead, the component lead time page sets out the options and what each one costs in scheduling terms.
Questions buyers ask about this part
Can it watch a 24 V rail? Not directly. The input stops at 10 V, so a 24 V rail needs a divider and the threshold moves with the resistor tolerance. The data sheet shows that circuit and the divider error it introduces.
Is the output safe to wire to a 3.3 V processor? Yes on the PL member. The high level is 0.8 times VDD, so at a 2.5 V rail the high level is 2.0 V, which is inside the input window of most 3.3 V parts but not of a 5 V part with a 0.7 times VDD threshold.
What happens below 300 mV? The output is undefined. If a downstream device must stay off all the way to zero, the enable path needs a pull-down that does not depend on the supervisor.