Contact Us

TPS3806I33DBVR

Brand: Texas Instruments
Texas Instruments TPS3806I33DBVR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS3806I33DBVR — Power Management & Signal Chain | Superb Automation

TPS3806I33DBVR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS3806I33DBVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS3806I33DBVR dual voltage detector with an adjustable hysteresis window

The TPS3806I33DBVR is a two channel voltage detector in a 6 pin SOT-23 body. One channel watches the supply itself against a fixed 3.0 V threshold, and the second watches an external node through a resistor divider and compares it with a 1.207 V reference. A third input sets a higher trip point on the same divider, so the part can hold a battery monitor in its fault state until the cell has recovered to a level the customer chooses rather than to a fixed margin above the trip point.

The two outputs leave the body independently. RESET follows the supply voltage and RSTSENSE follows the external node, both are active low and both are open drain, so neither can drive a logic high without a pull up resistor on the board.

Key parameters taken from the TPS3806 document

Supply range1.3 V to 6 V on VDD, with the inputs allowed up to VDD plus 0.3 V
Supply threshold2.978 V minimum, 3.0 V typical and 3.022 V maximum at 25 degrees, widening to 2.94 V and 3.06 V over minus 40 to plus 85 degrees
Sense threshold1.207 V reference, printed as 1.198 V to 1.216 V at 25 degrees and 1.183 V to 1.231 V over the full range
Built in hysteresis60 mV when the trip point sits between 1.2 V and 2.5 V, and 90 mV when it sits between 2.5 V and 3.5 V
Adjustable hysteresisThe HSENSE input sets an upper trip point through the same divider, so the release level is a customer number and not a fixed margin
Supply current3 microamp typical and 5 microamp maximum at 3.3 V, 4 microamp typical and 6 microamp maximum at 6 V
Input leakage25 nA maximum on LSENSE and HSENSE over the full temperature range
OutputsTwo independent open drain, active low, one from the supply and one from the sense node
Propagation5 microseconds typical and 100 microseconds maximum in both directions
Pulse width5.5 microseconds minimum at the supply pin for a reset to be recognised
Reset at power upThe output is valid down to a 0.8 V supply
TemperatureMinus 40 to plus 85 degrees C
Package and reelSOT-23 6 pin DBV, 3000 pieces on a large reel as DBVR and 250 pieces on a small reel as DBVT, body marking PGPI
HandlingMoisture level 1 at 260 degrees with unlimited floor life, nickel palladium gold lead finish

The 3.0 V threshold is worth reading against the rail rather than on its own. A 3.3 V rail at minus 5 per cent is 3.135 V, which sits above the 3.06 V worst case threshold, so the part asserts only after the rail has left its own tolerance band. A supply that is allowed to sit at minus 8 per cent for long stretches would sit inside the detector window and trip it, which is a statement about the regulator rather than about the detector.

Where the numbers matter in a real build

The divider is the part of this circuit that decides everything else. The lower trip point follows the ratio of R2 plus R3 to the total string against the 1.207 V reference, and the upper trip point follows R3 alone against the same reference, so the hysteresis window is a ratio of two resistor pairs on one string. The vendor recommends a total resistance of 1 megohm to keep the standing current small, and at that value the 25 nA of input leakage moves the trip point by roughly 25 mV, which is 2 per cent of the reference and has to be added to the resistor tolerance before the window is signed off.

The 90 mV of internal hysteresis applies because a 3.0 V trip point sits in the 2.5 V to 3.5 V band. That is enough to stop a rail that is loaded in bursts from chattering the output, and it is not enough to cover a supply that sags several hundred millivolts when a radio transmits. Where the sag is real, the HSENSE divider is what buys the extra margin, and the two outputs let the processor see which of the two nodes went low first.

The 5 microamp maximum supply current is a ceiling over temperature, not a typical. On a product that sleeps on a coin cell for a year, that current is the difference between a cell that lasts and a cell that does not, and it is the reason this part stays on boards where a general purpose comparator with a reference would cost less.

What to check before a purchase order is released

  • The reel suffix, because DBVR ships 3000 pieces on a large reel and DBVT ships 250 on a small reel of the same body.
  • The sibling part, because the TPS3806J20 shares the body, the pinout and the 1.207 V reference but watches a 1.8 V supply instead of a 3.0 V one.
  • The pull up resistors on both outputs, since open drain with no pull up leaves the processor reset line floating.
  • The HSENSE connection when the adjustable window is not used, because an unused input on a divider string still loads the node it is tied to.
  • The divider tolerance stack, resistor tolerance plus reference window plus leakage, before the release level is quoted to a customer.

Which projects this part fits

Battery monitoring is the first case. A 3.6 V lithium cell that has to be flagged at one level and released at a higher one is exactly a two threshold problem, and the second channel can watch the same cell while the first watches the regulated rail. Industrial controllers that keep a 3.3 V rail alive from a backup cell are the second case, and handheld instruments that must not restart while the battery is being changed are the third. The same body is also used where a processor has to be told that an external supply, rather than its own, has dropped out.

Questions that come up before a purchase order is released

Can the 3.0 V threshold be moved?

No. The supply threshold is set by an internal divider and the part is ordered by that number. Moving it means the J20 member at 1.8 V, or a different family with an adjustable input on both channels.

Do both outputs have to be used?

No, but the unused output still needs its pull up or its net has to be left unconnected deliberately, and the unused sense input should be tied to a node that stays inside its window rather than left open.

How fast does the output respond?

Between 5 and 100 microseconds depending on how far the monitored node has moved past the threshold. A slow rail that crosses by a few millivolts takes the long end of that window.

How SUPERB handles this line

Detectors and supervisors are usually ordered in the tens and hundreds rather than in full reels, so the question is a reel split and a date code rather than a catalogue price. Our power management cross reference covers what a single chip detector replaces in discrete comparators and references, and the incoming inspection plan describes what we check on a mixed analogue reel before it reaches the line. When a board is carrying an older detector that the vendor has moved to end of life, the obsolete part cross reference hub is where we start.