TPS26632RGER
Product Specifications
TPS26632RGER
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS26632RGER from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS26632RGER 60 V 6 A industrial eFuse with a 31 milliohm FET
The TPS26632RGER is the 24 pin VQFN member of the TPS2663x family, a 60 V industrial eFuse with an integrated 31 milliohm hot swap FET, a driver for an external blocking FET and a set of protection blocks built around the IEC 61000-4-5 surge test. The part sits between a 24 V or 48 V industrial bus and the load, and its job is to let the load start without dragging the bus down, to cut the load off when it faults, and to survive the surges that arrive on a factory supply.
What separates this member from the other five in the family is the fault response and the power limiting option. The table splits the family by overvoltage behaviour, by whether the current limit supports a 2x pulse, and by whether output power limiting is fitted. The 632 is the plain active current limiting member without the pulse support and without the adjustable power limit, which makes it the one to pick when the load is well behaved and the bus is the thing that needs protection.
Key parameters taken from the TPS2663x document
| Operating voltage | 4.5 V to 60 V, with 67 V absolute maximum on the input |
| Integrated FET | 60 V, 31 milliohm on resistance, hot swap rated |
| Current limit | Adjustable from 0.6 A to 6 A with 7 per cent accuracy |
| External FET driver | B-FET gate driver for reverse polarity protection and reverse current blocking with an external N-channel device |
| Reverse current | Fast blocking, 0.17 microsecond typical |
| Overvoltage | Adjustable cutoff with a resistor divider, plus fixed clamp options in other members |
| Undervoltage | Adjustable lockout on the same divider |
| Inrush control | Output slew rate set by a capacitor, with thermal regulation while charging large or unknown capacitive loads |
| Current monitor | Analog IMON output, 6 per cent accuracy |
| Status | PGOOD output for enabling downstream converters, plus a fault output |
| Fault response | Selected by the MODE pin between latch-off and auto-retry |
| Standards | UL 2367 recognised under file E169910, IEC 62368-1 certified, IEC 61000-4-4 and IEC 61000-4-5 system level immunity with class A performance |
| Package | VQFN RGE, 24 pins, 4 mm by 4 mm |
| Carrier | Large reel tape, moisture level 2 at 260 degrees with one year floor life |
The document prints these as limits with conditions attached. The current limit accuracy assumes the resistor tolerance is included, so a one per cent resistor is the right choice whenever the limit is a safety number rather than a housekeeping number.
Where the numbers matter in a real build
The first number that bites is the 67 V absolute maximum against a 60 V working rail. A 48 V bus with a hot plug event and a long cable can ring well above its steady value, and the part survives the ring but the external components around it have to be chosen for the same stress. The document shows the input capacitor and the TVS as part of the reference circuit for exactly this reason.
The second is the thermal behaviour while charging a large capacitance. The family regulates the pass FET thermally during start-up, which means a 1000 microfarad load does not trip the current limit but instead stretches the start-up time until the FET reaches its thermal regulation point. On a board with four such rails the start-up sequence has to allow for that stretching, otherwise the downstream converter enables before the bulk capacitor is charged and the rail sags.
The third is the reverse current path. The 0.17 microsecond blocking time is fast enough that a bus collapse does not push current backwards through the load, but the blocking action needs the external FET in place. A build that omits that FET and relies on the integrated switch alone loses the reverse polarity protection the family is specified for.
- Whether the assembly carries the external blocking FET, because reverse polarity protection depends on it.
- The current limit resistor tolerance, one per cent where the limit appears on a safety label.
- The dVdt capacitor against the real load capacitance, and the start-up window that follows from it.
- The divider on the overvoltage and undervoltage pins, since a 48 V bus sits close to the top of the range.
- The thermal copper under the 4 mm body, because 6 A through 31 milliohm is 1.1 W in a small package.
- The moisture level and floor life record, which decides whether a reel needs baking before reflow.
Which projects this part fits
The document lists factory automation and control PLC, DCS, HMI, input and output modules and sensor hubs, plus motor drives, CNC and encoder supplies, and electronic circuit breaker products. The pattern in all of them is a 24 V or 48 V bus feeding a load that can short, and a requirement that the bus keeps running while the faulty branch is cut off.
Questions that come up before a purchase order is released
Why does this part need an external FET as well as the internal one?
The internal FET is the hot swap switch. The external FET, driven from the B_GATE pin, provides reverse polarity protection and reverse current blocking. Without it the part still limits current and cuts off faults, but the reverse path is not protected.
How is the 632 different from the 633?
They share the body and the pinout and differ in overvoltage behaviour and in the pulse current support. The 632 uses adjustable overvoltage cutoff and plain active current limiting, which suits a bus that is already clamped upstream.
Does the part pass IEC 61000-4-5 on its own?
The document describes the surge and fast transient performance with the reference circuit components fitted, including the input TVS. The rating belongs to the assembly, not to the bare package.
Can the current monitor drive an ADC directly?
Yes, IMON is an analog output with 6 per cent accuracy over the range. A series resistor and a small filter capacitor are what the reference circuit shows.
What happens if the load capacitance is unknown?
The thermal regulation loop during start-up is the answer the document gives. The part holds the current at a level the FET can sustain rather than tripping, so the start-up time becomes a function of the load rather than a fixed number.
How SUPERB handles this line
A 60 V eFuse on a 48 V bus usually comes with a blocking FET, a TVS, a divider network and a bulk capacitor in the same shipment, and the build is only as good as the weakest of those parts. Our power management cross reference covers the protection families this part is bought against. The one stop BOM sourcing page sets out how a mixed bill of that kind is quoted, and our date code management covers the reel records that a safety audit asks for.