Contact Us

TPS26621DRCR

Brand: Texas Instruments
Texas Instruments TPS26621DRCR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS26621DRCR — Power Management & Signal Chain | Superb Automation

TPS26621DRCR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS26621DRCR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS26621DRCR: 60 V, 800 mA industrial eFuse with auto retry

TPS26621DRCR is a high voltage eFuse with a back to back FET body and integrated input reverse polarity protection in a VSON body of 10 pins. It protects a 4.5 V to 60 V bus against overload, reverse polarity and surge, and it retries after a fault instead of staying latched.

Order code and package

Order codeTPS26621DRCR, DRC package, 3000 pieces on a reel
BodyVSON, 3.00 mm by 3.00 mm, ten pins plus PowerPAD
Overvoltage behaviourAdjustable cut off on this member, the fixed 38 V clamp belongs to TPS26622 and TPS26623
Fault responseAuto retry on overcurrent and on overtemperature
Reverse polarityInput side integrated to 60 V, output side only on TPS26624 and TPS26625

Electrical parameters that decide the application

Input range4.5 V to 60 V operating, 62 V absolute maximum, 70 V for 10 ms
On resistance478 mOhm typical at 25 C, 626 mOhm at 85 C, 800 mOhm maximum over the full range
Current limit25 mA to 880 mA set by RILIM, 5 per cent accuracy at 880 mA, 7.5 kOhm minimum
Limit points7.5 kOhm gives 0.88 A, 44.2 kOhm gives 0.152 A, 267 kOhm gives 0.025 A
Single point failureRILIM open gives 8 mA to 27 mA, RILIM shorted gives 31 mA to 51 mA
Reverse comparatorTrips when the input falls 40 mV to 71 mV below the output, blocking in 0.3 us
Supply current343 uA enabled, 11.5 uA in shutdown, 50 uA into a reversed input
Thermal155 C trip, 10 C hysteresis, 130 ms retry, 44.8 C/W junction to ambient

Family variants and how they differ

TPS26620Same part with latch off instead of auto retry
TPS26622Fixed 38 V clamp with latch off, for a bus that must ride through a surge
TPS26623Fixed 38 V clamp with auto retry
TPS26624Latch off with input and output side reverse polarity protection
TPS26625Auto retry with input and output side reverse polarity protection

Points to check before this part goes on a BOM

The 478 mOhm is two FETs in series, not one. At the full 0.8 A the drop is 382 mV and the dissipation 0.31 W, which 44.8 C/W turns into a 14 C rise at 25 C. At the 800 mOhm full temperature limit the same current gives 0.51 W and a 23 C rise, and a 24 V bus that survives a short has to absorb the limit current times the bus voltage until the thermal circuit trips.

The limit table is unusually well specified and worth reading before choosing a resistor. 7.5 kOhm gives 0.83 A to 0.91 A, 44.2 kOhm gives 0.145 A to 0.159 A, and 267 kOhm gives 20 mA to 32 mA. A load that draws 0.85 A sits inside the window of a part at the bottom of the 7.5 kOhm band, so a 0.85 A load belongs on a part set above it or on the next device up.

The single point failure numbers are the reason this part exists in industrial equipment. An open RILIM limits to 27 mA at most and a shorted RILIM to 51 mA, both far under any real load, so a failed resistor cannot leave a bus unprotected. That is what the UL 2367 recognition and the IEC 62368-1 single point failure test are about.

Input reverse polarity is handled inside the part up to 60 V, but output side reverse polarity is not, on this suffix. When a 24 V bus collapses and a large output capacitor holds the output above the input, the reverse comparator sees a 40 mV to 71 mV inversion and blocks within 0.3 us, which is the case the back to back body is for. When the output is actively driven above the input by an external source, only the TPS26625 has the second protection.

The overvoltage choice changes what the load sees. This member opens the FET when the OVP pin crosses 1.2 V and retries later, so the load is interrupted. The clamp members pass a regulated 38 V instead, which keeps a downstream converter alive through a load dump but exposes it to 38 V. A 24 V input converter rated to 40 V rides through the clamp, and one rated to 30 V does not.

The UVLO and OVP pins are 1.2 V comparators with 100 nA of leakage and a 5 V rating, so a divider from a 48 V bus has to hold the pin under 5 V and still deliver enough current to swamp the leakage. A 1 MOhm top resistor at 48 V carries 48 uA, which is 480 times the leakage, and sets the divider current at a level where a 1 per cent resistor pair is the accuracy limit rather than the pin.

The dVdt pin charges at 1.98 uA and the output follows it at a gain of 24.6, so a 22 nF capacitor gives an output ramp of about 2.2 V/ms. That is the number that decides inrush into a 100 uF load, which would be 0.22 A and inside the 0.88 A limit with room for the load itself.

The 343 uA enabled current is not small for a battery fed bus, since it is 3 Ah over a year. On a mains powered industrial rack it is nothing, but on a solar or battery node the SHDN pin exists for exactly this, and pulling it low takes the part to 11.5 uA while the bus stays connected.

The surge and fast transient claims assume the external parts do the clamping. IEC 61000-4-5 at 1 kV needs a TVS or a metal oxide varistor in front of the part, because the 62 V absolute maximum is a semiconductor limit and not a surge rating. The eFuse then rides through the residual, which is what the back to back body and the 0.3 us reverse blocking are for.

The 70 V for 10 ms figure is a transient allowance, and the difference from the 62 V absolute maximum is the whole point of quoting both. A 48 V bus with a 500 V surge suppressor that clamps at 65 V stays inside the 10 ms window and outside the absolute maximum at the same time, so the part survives a pulse that would destroy a 60 V only device.

Where this order code fits

The part belongs on a 24 V or 48 V industrial bus at the entry point of a rack, a drive or a remote I/O block, where a miswired connector, a surge and a shorted field cable are all normal events. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.

Questions buyers ask

Can it sit directly on a 48 V bus? Yes, 60 V is the operating limit and 62 V the absolute maximum, with 70 V allowed for 10 ms. A 48 V bus at plus ten per cent is 52.8 V, which leaves room for the clamp margin.

Does it latch off after a short? No, this suffix retries every 130 ms after the junction cools by 10 C. The TPS26620 is the latch off version in the same body.

What sets the output ramp? One capacitor from dVdt to RTN. The pin charges at 1.98 uA and the output follows at 24.6 times that ramp.

Is the current limit accurate enough for a 0.5 A load? 0.5 A needs about 13.3 kOhm, which gives 0.47 A to 0.52 A. A load that must have 0.5 A continuously is at the top of that window and should be moved to a higher setting.

Can the part sit on a bus that is hot plugged? Yes, the input side reverse protection and the 70 V 10 ms allowance cover a hot plug on a 48 V bus, provided the connector and the TVS are rated for the same event.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.