TPS26614DDFR
Product Specifications
TPS26614DDFR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS26614DDFR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS26614DDFR 50 V loop protector with auto-retry for multiplexed inputs
The TPS26614DDFR is the auto-retry member of the TPS2661x current loop protector family. It carries the same 50 V working rating, the same 7.5 milliohm pass pair and the same fixed bipolar 32 mA limit as the rest of the table, and it adds two behaviours that matter on a multiplexed front end: after a fault clears it starts again on its own, and it does not need a supply rail to pass the loop for a test.
The family exists because a 4 mA to 20 mA input on an industrial card is exposed to three separate hazards. The field wiring can be connected to the wrong terminal. The field supply can be reversed or connected across the loop. A surge on a long cable can arrive at the connector with more energy than the ADC can absorb. A discrete answer uses a fuse, a diode bridge and a current source; the TPS2661x puts those blocks into an eight pin SOT-23 and keeps the insertion loss in the milliohm range.
Key parameters taken from the TPS2661x document
| Working voltage | 50 V across the loop, 55 V absolute maximum |
| Current limit | Bipolar, 25 mA minimum to 40 mA maximum, 32 mA nominal |
| Start-up limit | MODE pin selects twice the limit during start-up |
| On resistance | 7.5 milliohm typical, so the loop burden stays small |
| Quiescent current | Below 100 nanoamp from the loop on an external supply |
| Fault response | Auto-retry after the fault clears, which is the difference from the latch-off members |
| Loop test mode | Yes on this member, so a loop can be checked with no supply rail present |
| Intended input | Multiplexed voltage and current inputs, and analog outputs |
| Status output | SGOOD flag, open drain |
| Transient ratings | IEC 61000-4-5 surge and IEC 61000-4-4 fast transient, both with an external TVS |
| Thermal | Thermal shutdown with hysteresis, plus a thermal regulation behaviour during long overloads |
| Package | SOT-23, eight pins, 2.9 mm by 1.6 mm |
| Protocol fit | HART compliant |
Every row above is read from the document. Where the document prints a range, the range is what a production test should carry, and the typical value is only a starting point.
Where the numbers matter in a real build
Auto-retry looks like the friendlier choice until the field case is examined. On a multiplexed card where one channel is shorted by a wiring error, an auto-retry part keeps the channel alive and the scan keeps running, so the other seven channels still report. On a two wire transmitter supply, auto-retry can put the loop into a limit and release cycle that the transmitter sees as repeated brownouts. That is why the family splits the two behaviours across members instead of choosing one.
The loop test mode is the second practical difference. A technician who wants to check a loop with the cabinet unpowered needs a path through the protector, and only the members with that mode provide one. A card built with the 612 cannot be loop tested from the field side without power on the rack, which is a commissioning step that shows up on a site visit rather than on a bench.
The 7.5 milliohm figure deserves a second look in a multiplexed front end. Eight channels in parallel through a shared return can add a small but real common impedance, and the burden resistor is usually chosen for a 2.5 V or 5 V full scale. The protector drop is 150 microvolt at 20 mA, well below the offset of most instrumentation amplifiers, so the reading error it contributes is inside the noise floor of the card.
- The fault behaviour, auto-retry here against latch-off on the 610, 611 and 612, because the same footprint carries both.
- Whether the card is commissioned with the rack powered, since only two members pass the loop without a supply.
- The TVS selection, because the surge and fast transient ratings assume one is fitted at the connector.
- The MODE pin strap, since it sets both the start-up multiplier and the overload timers.
- The SGOOD pull-up rail, which must be present whenever the card is powered even if the loop is not.
- The moisture label and reel size on the purchase order, because a partial reel from a broker can arrive without its floor life record.
Which projects this part fits
The document names factory automation and control PLC analog modules, motor drive control, HART inputs, HVAC controllers, UART input and output protection and thermal controllers. The 614 member is aimed at multiplexed voltage and current inputs and at analog outputs, which is the shared front end pattern used on compact remote IO blocks.
Questions that come up before a purchase order is released
Will auto-retry hide a real fault from the controller?
The SGOOD flag follows the state of the path, so the controller can count retries and report a channel that keeps recovering. Auto-retry does not mask the event, it only keeps the other channels alive.
Can a 0 mA to 20 mA loop use the same part?
Yes. The family is listed for 0 mA to 20 mA, 4 mA to 20 mA and 20 mA loops, and the 50 V rating is what covers the higher compliance voltage loops.
What is the difference against a discrete fuse and diode bridge?
The discrete circuit drops volts and needs a resettable fuse that ages. The integrated part drops 150 microvolt at 20 mA and recovers without a field visit.
Does the part work with a unipolar supply only?
Yes, from 3 V to 30 V, and the loop path still blocks in both directions. The bipolar option from 2.25 V to 20 V is for cards that already carry a negative rail.
How SUPERB handles this line
Analog cards usually arrive as a full bill of material rather than as a single line item, and the protector is one of the parts that decides whether the card passes its own surge test. Our power management cross reference covers the protection families this part replaces. The incoming inspection plan sets out what we check on a reel before it goes to the line, and the shortage recovery page covers the case where a reel is short and the build cannot wait.