Contact Us

TPS259541DSGR

Brand: Texas Instruments
Texas Instruments TPS259541DSGR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS259541DSGR — Power Management & Signal Chain | Superb Automation

TPS259541DSGR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS259541DSGR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS259541DSGR 4 A eFuse with a 13.7 V clamp for twelve volt rails

The TPS259541DSGR is the 12 V member of the TPS2595 family. It runs from 2.7 V to 18 V, holds a typical 34 milliohm pass path, limits current up to 4 A with one resistor, and clamps the output at 13.7 V when the input rises above that level. The body is an eight pin WSON of 2 mm by 2 mm and the response to a fault is auto-retry.

On a 12 V rail the clamp level is the whole point. A 5 V member clamps at 5.7 V, which on a 12 V rail would sit below the operating voltage and hold the board off permanently. A member with a 13.7 V clamp lets a 12 V rail work normally and still protects the load from a 24 V adapter, a load dump on a vehicle rail or a transient that passes the input capacitor. Choosing between the 531 and the 541 is therefore a question about the rail, not about the current rating.

Key parameters taken from the TPS2595 document

Input range2.7 V to 18 V operating, 20 V absolute maximum
On resistance34 milliohm typical at 25 degrees, 47 milliohm over the junction range, 53 milliohm below 4 V of input
Current limit window0.5 A to 4 A with 7.5 per cent accuracy
Limit settingOne resistor on the ILM pin, printed as 2000 divided by the limit in amps minus 0.04
Published limit points487 ohm for 4.17 A, 1.78 k for 1.17 A, 4.42 k for 0.49 A
Overvoltage clamp13.7 V typical threshold with a 13.3 V to 14.3 V window, output held near 13.55 V
Clamp response5 microsecond typical at 4 A, 10 microsecond at 100 mA
Current monitor276 microamp per amp typical on the ILM pin
Slew rate38.2 V per millisecond from 12 V with the pin open, about 12 V per millisecond with 3300 pF
Thermal shutdown157 degrees junction rising, 5 degrees hysteresis, retry interval 93 milliseconds
EnableActive high, with an adjustable undervoltage lockout on the same pin
PackageWSON DSG, eight pins, 2 mm by 2 mm
Carrier3000 pieces on a large reel, 250 on a small reel for the T suffix
Marking and gradeMoisture level 2 at 260 degrees with a one year floor life, minus 40 to plus 125 degrees
RecognitionUL 2367 file E169910 and IEC 62368-1 certification

Rows are read from the vendor document. The clamp row carries a window, 13.3 V to 14.3 V, and that window is the number a system check has to use, because the load must tolerate the top of it rather than the typical value.

Where the numbers matter in a real build

A clamp at 13.7 V on a 12 V rail leaves about 1.4 V of headroom to the typical threshold and 0.7 V to the bottom of the window. A vehicle rail that sits at 13.8 V in normal charging is already above the typical clamp point, which is the reason this member is specified for a regulated 12 V adapter rather than for an automotive battery rail. In a vehicle a higher clamp level or a different family is needed, and the same body with the same pinout will not tell a buyer that.

The clamp window also decides what the downstream converter must tolerate. The output is held near 13.55 V while the input is above the threshold, so a converter rated to 16 V is comfortable and a converter rated to 13 V is not. The response time is 5 microseconds at 4 A, which is short enough that the output capacitor is what carries the load during the transition, and the capacitor has to be sized for that.

The thermal path is the constraint at 12 V. A 4 A load through 34 milliohm is 0.54 W, but during a clamp event the pass FET absorbs the difference between the input and 13.55 V at whatever current the load draws. A 24 V adapter into a clamped output is 10.5 V of drop, which at 1 A is over 10 W inside a 2 mm body. That is why the clamp is a transient protection rather than a regulator, and why a persistent overvoltage ends in thermal shutdown after a short time rather than in a stable clamped state.

The limit equation keeps the same shape as the rest of the family, 2000 divided by the limit in amps minus 0.04, with 487 ohm as the 4.17 A point. At 12 V the 4 A limit is rarely reached by the load itself, so the limit is mostly there to protect the connector and the upstream supply during a fault, and the exact value matters less than its tolerance against the supply's own current capability.

The retry interval is fixed at 93 milliseconds on this member. That means a faulted load causes a hiccup at about 10 Hz, which is audible on some loads and invisible on others, and a product that has to avoid an audible pattern has to either latch the part off or remove the fault. The L member of the same table is the latch-off option for that case.

  • The clamp level against the real rail, since a 12 V adapter and a 13.8 V battery rail are not the same input.
  • The top of the clamp window, because the load must survive 14.3 V rather than the typical 13.55 V.
  • The output capacitor, which carries the load during the 5 microsecond clamp response.
  • The dissipation during a clamp event, which is far above the steady state figure.
  • The retry pattern, because a 10 Hz hiccup can be audible in the product.
  • The reel size and the moisture level, which set the line handling rather than the electrical behaviour.

Which projects this part fits

The vendor lists hot swap and hot plug, adapter powered systems, multifunction printers, storage drives, industrial systems, white goods, set top boxes and televisions. A 12 V rail with a 13.7 V clamp fits a monitor, a set top box, an industrial controller or a printer that runs from an external adapter and has to survive the wrong one being plugged in.

Questions that come up before a purchase order is released

Can this part be used on a 5 V rail?

It can conduct, but the clamp sits at 13.7 V, so a 12 V adapter on a 5 V rail would pass through and damage the load. The 531 member with the 5.7 V clamp is the right choice for a 5 V rail.

Is the clamp a regulator?

No. It holds the output while the event lasts and the pass FET absorbs the difference, so a persistent overvoltage ends in thermal shutdown rather than in a stable output.

What limits the current during a clamp event?

The current limit still applies, and the thermal shutdown bounds the time the part can absorb the drop. The two mechanisms work together rather than one replacing the other.

Can the output be discharged when the part is off?

Not on this member. The quick output discharge option belongs to the 535 member of the same family, which carries the same clamp level with a discharge path.

What is the difference between the R and T carrier?

The R is 3000 pieces on a large reel and the T is 250 pieces on a small reel. The electrical part is the same.

How SUPERB handles this line

This is a commodity part where the risk sits in the suffix rather than in the silicon, and a mixed reel is the usual failure mode on a line. Our power management cross reference lists the members and their clamp levels, our date code management page covers how reels are kept separate, and our cost reduction page covers where a family like this can be consolidated without changing the board.