Contact Us

TPS25942ARVCR

Brand: Texas Instruments
Texas Instruments TPS25942ARVCR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS25942ARVCR — Power Management & Signal Chain | Superb Automation

TPS25942ARVCR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS25942ARVCR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS25942ARVCR 2.7 V to 18 V 5 A eFuse power multiplexer with a current limit and thermal shutdown response

The TPS25942A is the power multiplexer member of the 18 V eFuse family. It does everything the single rail part does, with a 42 milliohm back to back path, an adjustable limit from 0.6 A to 5.3 A and a current monitor output, and it adds the arrangement a product needs when two supplies feed one rail and only one of them may be connected at a time.

The family has two fault responses and the orderable string decides which one is on the board. The TPS25942 holds the current limit and relies on thermal shutdown to end a fault, while the TPS25944 starts a 4 ms timer and then shuts off. Both are printed in the device comparison table, and a buyer who assumes the two members behave the same will be surprised by the first sustained overload.

Key parameters taken from the TPS25942ARVCR document

Operating range2.7 V to 18 V, with 20 V absolute maximum
Current pathBack to back FETs, 42 milliohm typical
Current limit0.6 A to 5.3 A adjustable at 8 per cent accuracy, 4.81 A maximum at a 20 k resistor
Current monitorAnalogue output with 8 per cent accuracy
Fault responseThis member holds the current limit and relies on thermal shutdown, while the 25944 member starts a 4 ms timer and then shuts off
MultiplexingThe back to back path allows two sources to feed one rail with controlled handover, which is the function the plain single path part does not provide
Enabled currentAbout 200 microamp typical
Disabled current15 microamp typical
Overvoltage and undervoltageBoth programmable with 2 per cent threshold accuracy
Reverse blockingTrue blocking, with a reverse voltage shutoff in about 1 microsecond
Ramp controlOne capacitor sets the output slew
Fault reportingPower good and fault outputs
Fail safeThe limit resistor is checked at start up, and an open or shorted resistor produces a defined current
ApprovalsUL 2367 recognized under file E169910, safe during the UL 60950 single point failure test
PackageWQFN of 20 pins
Carrier3000 pieces on a large reel
MoistureLevel 2 at 260 degrees with a one year floor life on the A row
Part marking25942A
TemperatureMinus 40 to plus 125 degrees on the A row

Every row above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for a first article.

Where the numbers matter in a real build

The two fault responses are the whole reason to read the orderable string. This member holds the current limit while the fault lasts and lets thermal shutdown end it, which means a shorted load produces a hot path and a shutdown rather than a clean off. The timer member turns off after 4 ms, which protects the path but also removes power from a load that might have recovered. A product with a load that draws a legitimate surge needs the first behaviour, and a product with a hard short needs the second.

Power multiplexing is not just two eFuses on one rail. The back to back arrangement lets the part hold one source off while the other feeds the load, and to hand over without letting the load capacitor discharge into the source that has just been removed. The handover has to be sequenced by the system, and the ramp capacitor on each path is what decides how fast the new source takes over the load.

The current monitor output at 8 per cent accuracy is the practical way to know which source is supplying the load. A product with a main adapter and a backup battery path can log the handover without adding a sense resistor, and the output also serves as an early warning when a source is close to its limit.

The 42 milliohm path gives about 1.2 W at 5.3 A, which in a 20 pin body is a thermal question rather than a routing detail. On a multiplexed rail the two paths share the package, so a handover transient that puts both paths on at once, even briefly, doubles that figure and is worth checking in the timing of the system sequencer.

The temperature range on the A row runs to 125 degrees, while the single rail member of the same family stops at 85 degrees on its addendum row. A product that needs margin at the top of the load range should compare the two addendum rows rather than assume the family number applies to both.

The 8 per cent accuracy of the current limit is a window, not a point, and on a multiplexed rail the window matters twice. A source that can deliver 4.6 A into a limit set at 4.81 A will sit in current limit for as long as the handover lasts, which raises the die temperature of both paths at the moment the second source is supposed to take over. A product that has to hand over under load should set the limit above the sum of the two load currents or sequence the handover so the load is reduced first.

The current monitor output is the cheapest way to know which source is actually supplying the load, and it is also the signal that a system needs to log a handover that happened for an unexpected reason. On a product with an adapter and a battery path, a handover in the middle of an operation is a symptom, and the monitor output is what lets a field log show the sequence rather than just the symptom.

  • The member, because the two fault responses produce very different behaviour on a sustained overload.
  • The handover sequence between the two sources, since the multiplexer does what the system tells it and nothing more.
  • The ramp capacitor on each path, which sets how fast the new source takes the load.
  • The limit resistor and its fail safe behaviour, which is the row a safety file will quote.
  • The combined dissipation during a handover, because both paths can conduct briefly.
  • The temperature range on the addendum row for this exact string, which differs from the single rail member.

Which projects this part fits

This part fits systems with a main supply and a backup supply feeding one rail, such as storage shelves, industrial controllers, point of sale terminals, telecom line cards and any product that has to switch between an adapter and a battery without dropping the load. It also fits boards where two input connectors are never used at once but both have to be protected.

Questions that come up before a purchase order is released

What is the difference between the TPS25942 and the TPS25944?

The fault response. This member holds the current limit and relies on thermal shutdown to end the fault, while the 25944 member starts a 4 ms timer and then shuts off.

Can it really multiplex two supplies?

Yes. The back to back path allows one source to feed the load while the other is held off, with the handover sequenced by the system. The part does not decide the sequence itself.

Does it need an external sense resistor?

No. The limit is set by a resistor and the current is reported on an analogue output at 8 per cent accuracy.

How fast does it block reverse current?

The reverse shutoff acts in about 1 microsecond, which is fast enough to keep a load capacitor from discharging into a source that has just been removed.

What happens on a sustained short?

On this member the current limit is held and the die temperature rises until thermal shutdown acts. A product that needs a clean off after a fixed time should use the timer member instead.

Is the temperature range the same as the single rail part?

No. The A row of this string reads minus 40 to plus 125 degrees, while the single rail member of the same family stops at 85 degrees on its addendum row.

How SUPERB handles this line

A power multiplexer is chosen on the fault response and on the handover sequence, and both have to be settled before the board is frozen. Our power management cross reference lists the devices this part is cross referenced against, our BOM consolidation service covers how we consolidate the two source paths into one approved bill, and our lead time planning service is the lead time picture on the passives and connectors around the same rail.