TPS2561ADRCR
Product Specifications
TPS2561ADRCR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS2561ADRCR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS2561ADRCR: Dual channel 2.5 V to 6.5 V current-limited power switch, 2.3 A per channel
TPS2561ADRCR is a two-channel power-distribution switch with an independent current limit and fault flag on each channel in a SON body of 10 pins. Each channel carries about 2.3 A from a 2.5 V to 6.5 V rail through 44 milliohm of switch resistance, both channels share one limit resistor, and each FAULT pin reports its own channel so a host can tell which port tripped.
Order code and package
| Ordering string | TPS2561ADRCR, DRC package, 3 mm by 3 mm SON, tape and reel |
| Enable sense | TPS2561A enables on a high input, TPS2560A on a low input |
| Marking | 2561A on the package |
| Package | 10-pin SON with a power pad, 3.00 mm by 3.00 mm |
| Ambient range | -40 C to 85 C, with the junction limit set by the board |
| Pin count check | Two inputs, two outputs, two enables, two fault outputs, ILIM, GND and the pad |
Electrical parameters that decide the application
| Input range | 2.5 V to 6.5 V |
| Switch resistance | 44 milliohm typical, 50 milliohm maximum, per channel at 25 C |
| Current limit at 24.3 kohm | 2.100 A minimum, 2.300 A typical, 2.500 A maximum |
| Supply current on | 85 microamp at 20 kohm, 110 microamp at 100 kohm |
| Supply current off | 0.1 microamp typical, 2.0 microamp maximum |
| Fault outputs | One open-drain FAULT per channel, asserted independently |
| Reverse protection | Comparator turns the channel off when the output is driven above the input |
Points to check before this part goes on a BOM
The 2.3 A headline is a typical value with a 2.1 A floor and a 2.5 A ceiling, which is a window of plus or minus 8.7 percent around the centre and not a guaranteed 2.3 A. A load that must not trip below 2.2 A cannot be served by this resistor value at the bottom of the window, and the next lower resistor setting is the only safe answer.
Both channels at 2.3 A with the maximum 50 milliohm are 0.53 W inside a 3 mm by 3 mm body, and that number is what the exposed pad and the copper under it have to carry. The data sheet states that the maximum ambient is a function of junction temperature and system level considerations, so the 85 C figure is a starting point and not a rating that holds at full load in a sealed enclosure.
The two enable polarities are not interchangeable across the family. TPS2560A is active low and TPS2561A is active high, so a rework that fits the other member of the pair inverts every host command and leaves both channels off while the firmware believes it has enabled them.
Off current of 2.0 microamp maximum applies to the whole part, both channels together, and works out to 17.5 mAh over a year. In a product that keeps the ports off while sleeping that is the number that belongs in the standby budget, while the 85 to 110 microamp on-state current is a running budget that no port state can avoid.
One limit resistor sets both channels, so a board that needs different limits on the two ports cannot use this part as it stands. Two single-channel switches with their own resistors are the route, and the cost difference is one package plus one resistor rather than a second limit pin that does not exist.
The FAULT pins are open drain and independent, which is the useful part of this device: a host can log which port tripped without cycling both. Each pin needs its own pull-up, and a single pull-up shared across the two will read low whenever either channel faults, which defeats the purpose.
Both channels share one ILIM node, so their limit windows move together with resistor tolerance and temperature drift, which is what a hub needs when it has to report two ports against the same specification. A 200 ppm per degree resistor over the 45 degrees from 25 C to 70 C moves the limit by 0.9 percent, a tenth of the window, while a five percent part uses more than half of the same window before temperature is counted at all, so the resistor grade is the cheap place to spend. Two ports fed from the same 5 V source also share the upstream drop, so the second channel sees a slightly lower input voltage and is the one that trips first under a common overload, which is worth knowing before a fault is blamed on a single port.
Where this order code fits
The common fit is a two-port USB hub, a pair of front-panel connectors, or a dual 5 V accessory rail where each outlet has to be protected and reported separately. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.
Questions buyers ask
Can the two channels be paralleled for 4.6 A? Not safely. The limits are set by one resistor and the two channels do not share current evenly, so the first to reach the limit takes the whole load. A single-channel part with the right resistor is the correct answer.
Why does the part get warm with a light load? The on-state supply current is 85 to 110 microamp depending on the resistor, which is small, so heat at light load usually comes from the switch resistance and a load that is not as light as the label says. Measure the voltage across the part rather than the supply current.
Does the limit accuracy hold over temperature? The datasheet window is quoted for the stated test conditions and the resistor tolerance adds to it. A one percent resistor keeps its share small; a five percent part consumes most of the margin between the minimum and maximum limit columns.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.