TPS2492PWR
Product Specifications
TPS2492PWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS2492PWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS2492PWR: 80 V hot swap controller with power limiting and an analogue current monitor
TPS2492PWR is a positive rail hot swap controller that drives an external N channel FET and holds it inside its safe operating area while a load capacitor charges in a TSSOP (PW) body of 14 pins. It works from 9 V to 80 V, sets the load current limit and the FET power limit with two resistor dividers, times the fault with one capacitor and reports load current as an analogue voltage. The current monitor scales the sense voltage by 48, so a 50 mV drop across the sense resistor appears as 2.4 V at the IMON pin.
Order code and package
| Order code read out | TPS2492 PW R: controller TPS2492 with latch off after fault, PW fourteen pin TSSOP, R large tape and reel |
| Package | TSSOP (PW), 14 pins, with a junction to ambient figure of 116.4 degrees per watt |
| Carrier in the vendor addendum | TPS2492PWR at 2000 pieces on a large reel; TPS2492PW is the same part in a 90 piece tube |
| Moisture level | Level 1, 260 degrees unlimited floor life |
| Lead finish | Nickel palladium gold, quoted as NIPDAU |
| Temperature grade | Junction minus 40 to plus 125 degrees for the order code on this page |
| Absolute maximum | 100 V on VCC, SENSE, UVEN and OUT; 6 V on GATE, PG and FLT; 6 V on TIMER, VREF and IMON; 10 mA into a logic pin |
Electrical parameters that decide the application
| Input range | 9 V to 80 V on VCC, with turn on between 8.4 V and 8.8 V and 100 mV of hysteresis |
| Reference | 3.9 V minimum, 4 V typical and 4.1 V maximum at the VREF pin, sourcing up to 1 mA |
| Current limit without power limiting | 45 mV minimum, 50 mV typical and 55 mV maximum across the sense resistor when PROG is held at 4 V |
| Current limit with power limiting | 17 mV minimum, 25 mV typical and 33 mV maximum, the folded back value that keeps the FET inside its area |
| Current monitor | VIMON equals 48 times the sense voltage, so a 1 milliohm shunt at 20 A gives 0.96 V |
| Fault timer | The TIMER pin charges at 17 to 36 microamp and trips at 2.1 to 3.1 V, then resets below 0.96 to 1.04 V |
| Retry duty cycle | 0.5 to 1 percent on the TPS2493 retry version, which is the wait between attempts |
| Power good | PG compares the sense and output pins and deglitches for 5 to 15 ms, so a fast transient does not toggle it |
| Overvoltage | The OV pin trips at 1.31 to 1.39 V with 90 mV of hysteresis and pulls the gate down for 40 to 220 microsecond bursts |
| Enable | UVEN turns on at 1.31 to 1.39 V with 100 mV of hysteresis, so a divider from the rail sets a precise undervoltage point |
| Gate drive | Sourcing 15 to 35 microamp and sinking 75 to 250 mA, which sets the charging slope of the external FET gate |
| Supply current | 665 microamp typical and 1000 microamp maximum enabled, 120 to 250 microamp disabled |
The pins that decide how the board behaves
| TPS2492PWR | latch off after a fault, cleared only by cycling the enable input |
| TPS2493 | the same controller with automatic retry, which is the version for an inaccessible card |
| PROG pin | sets the power limit by holding the FET in a fixed dissipation window rather than at a fixed current |
| SENSE and OUT pins | measure the drop across the external FET, which is what makes the power limit possible without a second sense resistor |
| TIMER pin | one capacitor sets how long the load may draw fault current before the gate is pulled down |
Points to check before this part goes on a BOM
The power limit is the reason this controller exists. A fixed current limit protects the supply but not the FET: into a short the FET sees the full bus voltage at the limit current, which for a 48 V rail and a 10 A limit is 480 W, far outside the safe operating area of any reasonable device. The PROG pin instead sets a power ceiling, so the controller reduces the current as the drain to source voltage rises. At 48 V and a 5 W ceiling the pass FET carries about 100 mA, which it can do indefinitely, and the timer decides when to stop.
Two current limits are published and the difference is not cosmetic. The 50 mV figure applies when PROG is held at 4 V, which effectively disables the power foldback, and the 25 mV figure applies when PROG is at 2.4 V and the output is at zero. A board that sets PROG from a divider and then measures the current limit on a bench supply will see the folded value, not the headline, and will conclude the part is out of specification unless the power limit equation is worked through first.
The current monitor output is a voltage equal to 48 times the sense voltage, which is convenient for a 3.3 V ADC. With a 1 milliohm shunt and a 30 A full scale the output reaches 1.44 V, comfortably inside a 3.3 V rail, and the resolution depends on the ADC rather than on the monitor. The pin needs no calibration resistor, but the 48 gain has its own tolerance and the sense resistor tolerance sits in series with it, so a current reading is a monitoring figure rather than a metering one.
The timer capacitor sets the inrush window, and the arithmetic is worth doing before a value is chosen. Charging at 27 microamp to 2.7 V takes about 100 milliseconds per microfarad, so a 10 nanofarad capacitor gives roughly 1 millisecond and a 1 microfarad capacitor about 100 milliseconds. The same capacitor also sets the retry period on the 2493 version, because the discharge path is what creates the wait, so a long inrush window also means a long retry wait.
The 80 V rating with a 100 V absolute maximum is what makes the part usable on a 48 V telecom rail, where a transient can reach 75 V and a lightning surge can go higher. The external FET has to be rated for the same bus, and the gate drive of 12 to 16 V above the output is high enough for a standard threshold device. A logic level FET is not needed and is usually a worse choice here because its thinner gate oxide is less tolerant of the transient.
Overvoltage handling is a gate pull down of 40 to 220 microseconds rather than a latch, so the controller rides through a short surge and returns to normal when the rail recovers. That behaviour suits a bus with occasional spikes and does not suit a rail that can stay high, where a latch or a crowbar is the better answer. The OV threshold is the same 1.35 V as the enable threshold, which allows one reference divider arrangement to serve both pins.
Where this order code fits
Used on server and storage backplanes, plug in modules, base station power inputs, medical equipment racks and any 9 V to 80 V rail that has to accept a card into a live bus without dragging the rail down or destroying the pass FET. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Strategic Sourcing page.
Questions buyers ask
Why is the current limit lower than the value in the headline? The 45 to 55 mV window applies only when PROG is at 4 V and the power foldback is inactive. With a normal PROG divider the controller reduces current as the FET voltage rises, so the measured limit into a short is the 17 to 33 mV value.
Can the monitor output drive an ADC directly? Yes, it is a voltage of 48 times the sense voltage with a 1.9 mA source capability, so a high impedance ADC input is fine. A series resistor and a small capacitor are still worth fitting to keep switching noise out of the sample.
What FET should be selected? One rated for the full bus plus margin, with an on resistance low enough for the steady state current and a safe operating area curve that covers the power limit for the timer duration. A device chosen only on on resistance will fail the second test.
How long can a fault last? Until the timer capacitor reaches its 2.7 V threshold, which is about 100 milliseconds per microfarad at the typical charge current. After that the TPS2492 latches off and the TPS2493 waits and retries.
Does it protect against reverse current? No. The external FET body diode conducts in the reverse direction and the controller has no reverse comparator. A redundant bus that can be back fed needs an ideal diode or a second FET in series.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Supplier Quality Audit page sets out the checks that keep a substitute from failing on the bench.