TPS2421-2DDAR 22+
Product Specifications
TPS2421-2DDAR 22+
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS2421-2DDAR 22+ from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS2421-2DDAR 5 A hot swap controller with an integrated FET, a power limit and automatic retry
The TPS2421-2 is the auto retry member of a two part family of integrated hot swap controllers. It puts the pass FET, the current sense, the power limit loop and a fault timer into one eight pin SO PowerPAD body, so a 3 V to 20 V rail can be limited to a power budget and a fault current without an external sense resistor. The device comparison table in the document reads latch off on fault for the TPS2421-1 and auto retry on fault for the TPS2421-2, which is the opposite of what many buyers assume from the suffix, so the orderable number is worth confirming against the table.
Three limits work together. A resistor from ISET to ground sets the fault current, and the hard current limit sits at 150 percent of that fault current. A power limit of 3 W to 7.5 W holds the dissipation inside the package while the output capacitance charges. A capacitor from CT to ground sets how long the part may stay in a fault before it acts, which is what keeps a short inrush event from looking like a fault.
Key parameters taken from the TPS2421-2DDAR document
| Input range | 3 V to 20 V recommended operating, 25 V absolute maximum on the input and output pins |
| Rated current | Up to 5 A, which is the top of the on resistance test window of 1 A to 4.5 A and the current the PowerPAD is sized for |
| On resistance | 33 mOhm typical and 50 mOhm maximum at 1 A to 4.5 A of load current |
| Fault current | 3.6 to 4.4 A with a 49.9 k resistor on ISET, set by the equation in the document |
| Hard current limit | 150 percent of the fault current, which is a ratio rather than a separate setting |
| Power limit | 3 W minimum, 5 W typical and 7.5 W maximum, which is the loop that holds the FET inside its safe area |
| UVLO | 2.85 V typical on VIN rising with a 2.6 to 2.9 V window |
| Fault timer | Set by the capacitor on CT, with a 35 microamp typical charge current while the part is in current limit |
| Fault flag | FLT pulls low when the fault time has expired and the FET is switched off |
| Power good | PG pulls low when the output is more than 300 mV below the input |
| Turn on | 350 to 500 microsecond from enable with a 3.3 V input and a 1 A load |
| Enable | Active low, so pulling EN to ground enables the part |
| Thermal | SO PowerPAD body, which is the reason the 5 W power limit exists |
| Package | SO PowerPAD DDA, 8 pins, 2500 pieces on a large reel and 75 pieces in a tube |
| Moisture and temperature | Level 2 at 260 C with a one year floor life, minus 40 to 125 C junction |
| Addendum status | The DDA and DDAR rows are Active and in Production, marking 2421-1 on the -1 rows and 2421-2 on the -2 rows |
Every row above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for a first article.
Where the numbers matter in a real build
The retry behaviour is the whole difference between the two members and it changes what an operator sees. On the auto retry part a fault that clears is followed by a restart without anyone touching the equipment, so a product that sits on a pole or in a cabinet recovers by itself. On the latch member the part stays off until the enable pin is cycled, which is what a server backplane wants because a board that faulted should not be allowed to retry into a shorted load while a technician is working on it.
The 5 W typical power limit is the number that decides how fast the output capacitance can charge. A 1000 microfarad load at 12 V stores 72 mJ, and the part will charge it at whatever current holds the FET at 5 W, which at 12 V is about 0.4 A while the output is near ground. That is the calculation that tells a product whether its 10 ms start up requirement is achievable, and the document gives the equations for start up time and for the minimum load resistance that keeps the part inside its power limit.
The CT capacitor sets the fault window and it interacts with the retry. A capacitor that is too small makes the part trip on the inrush of its own load capacitance, which then looks like a permanent fault and produces an endless restart cycle. A capacitor that is too large lets the FET sit in current limit long enough to heat the package, and the thermal shutdown then becomes the thing that acts instead of the timer. The document gives the equation for the fault time against the capacitor value, and it is worth solving that equation for the worst case tolerance rather than the typical one.
The 50 mOhm maximum on resistance is where the steady state loss sits. At 3 A that is 450 mW, and inside an eight pin SO PowerPAD with a modest copper area the junction rises well above ambient. A product that runs 4 A continuously through this part in a sealed box should measure the case temperature rather than trust the ambient rating, because the 125 C junction limit arrives sooner than the load current suggests.
The power good threshold of 300 mV is a useful signal but it is not a precision comparator. It tells the downstream converter that the output is close to the input, which is the right condition to release its enable, but a converter that starts at 90 percent of its input voltage will still see a rail that is 300 mV low if it is enabled on the edge of the window. The usual fix is to add a small delay, not to tighten the expectation of the pin.
- Fault current setting against the load current and the inrush, since the hard limit is 150 percent of the set value rather than an independent number.
- CT capacitor against the fault time in the equation, solved at the worst case tolerance instead of the typical value.
- Power limit against the output capacitance and the start up time the product needs.
- On resistance at the real load current, because the 50 mOhm maximum is what the thermal calculation has to use.
- Enable polarity, which is active low on this part, so a floating pin can turn the rail on.
- Fault flag behaviour in the retry cycle, since a system controller that latches on the first FLT will defeat the auto retry.
Which projects this part fits
This part fits line cards, disk shelves, industrial PCs, point of sale terminals and telecom access equipment where a 5 V or 12 V rail has to be current limited and power limited without an external sense resistor. It also fits battery powered equipment that has a hot pluggable module, because the retry behaviour means a module that is inserted slowly and makes a brief contact will start up on the second attempt instead of staying dead.
Questions that come up before a purchase order is released
Which member retries and which one latches?
The device comparison table in the document reads latch off on fault for the TPS2421-1 and auto retry on fault for the TPS2421-2. Buyers often assume the other way round from the suffix, so the table is the reference and the orderable number should be checked against it.
Is the current limit adjustable independently?
No. A resistor on ISET sets the fault current, and the hard current limit is fixed at 150 percent of it. A product that needs a tighter window has to accept the ratio or choose a controller with separate settings.
What does the CT capacitor do?
It sets the fault time. The part sources about 35 microamp into the capacitor while it is in current limit, and when the voltage reaches the internal threshold the part acts, either latching off or retrying depending on the member.
Can the part survive a permanent short?
The power limit and the fault timer together keep the FET inside its safe area until the timer expires, and thermal shutdown is the last line. A permanent short on the output is a fault the part will handle, but the board still has to survive the current the upstream supply delivers before the timer acts.
Why is the power limit set at 5 W?
Because the package can dissipate about that much with the copper area a normal board gives it. A higher limit would charge the load capacitance faster and cook the part, and a lower limit would make start up into a large capacitance take longer than most products allow.
Does the part need an external sense resistor?
No, the sense element is inside the package. That is the reason to choose this family over a controller with an external FET when the current is under 5 A.
How SUPERB handles this line
We supply the TPS2421-2DDAR on original 2500 piece reels and as 75 piece tubes, with the date code and marking recorded on the packing list. The power management cross reference page lists the integrated hot swap parts we carry by voltage and current, pin to pin cross reference covers the controllers that share this land pattern, and safety stock planning is how we hold cover on the parts that go into a long life platform.