Contact Us

TPS22976DPUT

Brand: Texas Instruments
Texas Instruments TPS22976DPUT is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS22976DPUT — Power Management & Signal Chain | Superb Automation

TPS22976DPUT

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS22976DPUT from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS22976DPUT: a dual channel 6 A load switch with 14 mOhm on resistance

TPS22976DPUT is a dual channel load switch that connects and disconnects two rails up to 6 A each, with a controlled rise time and a thermal shutdown that protects the switch rather than the load in a WSON body of 14 pins. Fourteen milliohms per channel at 6 A is 0.5 W of conduction per channel, which is why the body has a thermal pad and why the ambient rating stops at 105 C.

Order code and package

Catalogue stringTPS22976DPUT, the plain member in the fourteen pin DPU body
BodyDPU, WSON, 14 pins with thermal pad, 3.00 mm by 2.00 mm, junction to case 6.5 C per watt
Reel250 pieces on a small reel and 3000 on a large reel, both printed for this string
Temperatureminus 40 to 105 C ambient
Family membersTPS22976, TPS22976A and TPS22976N share the body and the pinout
DocumentSLVSDE7D, revised December 2023
Discharge optiona 230 ohm load resistor can be switched in when the channel turns off

Electrical parameters that decide the application

Input range0.6 V up to the bias voltage, so the switch passes rails below 1 V without a level shift
Bias range2.5 V to 5.7 V, which sets the gate drive and therefore the on resistance
On resistance at 5 V bias14 mOhm typical per channel, 22 mOhm maximum over minus 40 to 85 C, 23 mOhm over minus 40 to 105 C
On resistance at 2.5 V bias18 mOhm typical, which is the number to use on a low voltage bias rail
Current6 A maximum continuous per channel
Quiescent current37 uA typical with both channels on at 5 V, 35 uA with one channel on, 49 uA maximum over the range
Quiescent, A member85 uA with both channels on, the price of the 17 us turn on
Shutdown currentbelow 2 uA with both channels off
Control thresholdscompatible with 1.2 V, 1.8 V, 2.5 V and 3.3 V logic without a translator
Rise timeset by a capacitor on the channel, 1770 us for a 1000 pF capacitor on this member
Turn off time3 us with the same capacitor, so the fall is much faster than the rise
Thermal shutdownintegrated, with the channel turning back on once the junction cools
On pin leakage0.1 uA at 5.5 V on the pin

Three members and the trade between them

TPS22976the standard member, 37 uA with both channels on and a rise time set by the capacitor
TPS22976Athe fast turn on member, 85 uA, 17 us at a 1.05 V input, for rails that have to come up quickly
TPS22976Nthe low quiescent member, for standby loads where the switch stays on while the product sleeps
QOD optionthe 230 ohm discharge resistor is fitted on some strings and not on others, so the string decides whether the rail is bled at turn off
Greened stringsthe G4 rows are the same part with a green material declaration

Points to check before this part goes on a BOM

Fourteen milliohms is quoted at a 5 V bias. With a 2.5 V bias the same channel is 18 mOhm typical, which at 6 A is 0.65 W instead of 0.5 W. On a board where the bias rail is 3.3 V the number sits between the two, and the maximum rows over temperature are the ones that decide the copper.

The thermal pad is not optional. At 0.5 W per channel and a 6.5 C per watt junction to case figure, the case sits 3.3 C above the junction side of the pad and the pad to ambient path carries everything. A land that is smaller than the pad turns a 30 C rise into a 60 C rise.

A rise time in the milliseconds and a fall time in the microseconds is the right shape for a load switch. The rise has to charge the load capacitance without pulling the upstream supply down, and the fall only has to remove the charge, so there is no reason to slow it.

The 105 C ambient rating is lower than the 125 C of many parts in this class. It is a consequence of the 6 A rating in a 3 by 2 mm body: the switch is thermally limited, and the vendor has chosen to stop the ambient range where the part can still hold its numbers.

Three members with the same pinout allow the same board to serve a fast start product and a low standby one. The N member is the one for a product that keeps a rail alive in sleep, the A member for a rail that has to be up before a processor releases its reset.

The discharge resistor is a 230 ohm path to ground, not a full discharge circuit. It removes the charge from a small capacitor quickly and from a large one slowly, so a rail with 100 uF takes about 23 ms to fall to a few per cent rather than the microseconds a dedicated bleeder would give.

Working out the rise time capacitor

The rise time is set by a capacitor per channel, and the vendor's table gives 1770 us for 1000 pF on the standard member. The relationship is close to linear, so a 100 pF capacitor gives a few hundred microseconds and a 10 nF one gives tens of milliseconds.

The value is chosen from the upstream supply, not from the load. The switch has to charge the load capacitance at a rate the supply can support, so a 6 A channel on a 2 A supply needs a slower ramp than the same channel on a 6 A supply.

Dual channel and the current that does not add up

Two channels of 6 A in one 3 by 2 mm body do not give 12 A of thermal capability. Each channel has its own switch and its own pad area, and the package as a whole has one thermal path, so the second channel loaded to 6 A raises the temperature the first one sees.

The practical limit is a total dissipation rather than a per channel current. Two channels at 3 A each dissipate the same as one channel at 6 A, which is the figure the package was characterised at.

Where this order code fits

This is the switch between a main rail and a subsystem that has to be powered down when idle, on a notebook, a set top box, a telecom line card or a solid state drive. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Kitting Service page.

Questions buyers ask

Can both channels carry 6 A at once? Electrically each channel can. Thermally the package has one path, so two channels at full current together run hotter than one, and the ambient derating applies to the pair.

What sets the on resistance? The bias voltage, not the input voltage. At a 5 V bias the channel is 14 mOhm typical, at 2.5 V it is 18 mOhm, and the input can be anywhere from 0.6 V up to the bias.

Is there a current limit? No. The switch has thermal shutdown but no current limit, so a short on the output is handled by the switch heating and turning off rather than by a fold back.

Why is the fall so much faster than the rise? Because the rise is deliberately slowed to limit inrush and the fall is not. The 3 us fall is the switch turning off, and the load capacitance discharges into the load.

Do I need the discharge resistor? Only if the rail has to fall quickly when the channel turns off. Without it the rail decays through the load, which on a light load can take seconds.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Safety Stock Planning page sets out the checks that keep a substitute from failing on the bench.