TPS22943DCKR
Product Specifications
TPS22943DCKR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS22943DCKR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS22943DCKR 40 mA current limited load switch with a 10 ms blanking window and latch off protection in SC-70
The TPS22943DCKR is a current limited load switch from the TPS2294x family, in a five pin SC-70 body, with a 40 mA minimum current limit, a 10 ms blanking window, an active high enable and no auto restart. It is the part a board uses to protect a small sensor, a connector, or a peripheral port where the load is tens of milliamps and the failure mode is a short that must not take the main rail down.
The family puts five variants around one die: two current limit levels, with or without auto restart, and active high or active low enables. This member combines the 40 mA limit with the 10 ms blanking and the latch off behaviour, which is the combination for a port that should stay dead after a fault until the host decides to retry. The overcurrent flag is open drain and active low, and it reports undervoltage and thermal shutdown as well as current limit, so one pin covers the three conditions that matter.
Key parameters taken from the TPS22943DCKR document
| Input range | 1.62 V to 5.5 V |
| On resistance at 5.5 V | 0.4 Ohm typical and 0.5 Ohm maximum |
| On resistance at 3.3 V | 0.5 Ohm typical and 0.6 Ohm maximum |
| On resistance at 2.5 V | 0.6 Ohm typical and 0.7 Ohm maximum |
| On resistance at 1.8 V | 0.8 Ohm typical and 0.9 Ohm maximum |
| On resistance at 1.62 V | 0.9 Ohm typical and 1.1 Ohm maximum |
| Current limit | 40 mA minimum, 65 mA typical and 80 mA maximum at 3.3 V input with a 3 V output |
| Blanking window | 10 ms of constant current before the switch turns off and the flag asserts |
| Auto restart | Not fitted on this member, so a fault latches until the enable is cycled |
| Overcurrent flag | Open drain, active low, asserted for current limit, undervoltage and thermal shutdown, with a 0.1 to 0.2 V low level at 10 mA |
| Under voltage lockout | 1.32 V minimum, 1.42 V typical and 1.52 V maximum rising, with 45 mV of hysteresis |
| Thermal shutdown | 140 C trip, 130 C recovery, 10 C of hysteresis |
| Quiescent current | 40 microamp typical and 80 microamp maximum, with the off state supply current below one microamp |
| Turn on and rise | 60 microsecond turn on and 30 microsecond rise into 500 Ohm and 0.1 microfarad at 3.3 V |
| Enable | Active high, with thresholds printed against each input voltage so a 1.8 V logic high is inside the window |
| Body and packing | SC70 DCK 5 pins, 3000 pieces on a large reel, NIPDAU finish, moisture level 1, minus 40 to plus 85 C, marking 4CN |
| Approvals | UL recognised component under file E169910 and evaluated to IEC 60950-1 with a CB report |
The table above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for the first article.
Where the numbers matter in a real build
The current limit window is the number to put in a test plan, not the typical. The published rows are 40 mA minimum, 65 mA typical and 80 mA maximum, which is a two to one spread on a part whose job is to protect a load. A sensor that draws 45 mA sits above the minimum and is therefore guaranteed to pass on every unit, while a load that draws 70 mA may pass on one part and limit on another. The right way to use a window this wide is to keep the normal load below the minimum with margin, and to accept that the limit is a protection threshold rather than a regulated current.
The 10 ms blanking window is what makes the part usable with a capacitive load. A short on the output pulls the switch into constant current immediately, and the part holds that current for 10 ms while the flag stays quiet. If the short clears the switch returns to normal, and if it does not the switch turns off and the flag asserts. A load with 10 microfarad charged through the 40 mA limit takes 0.8 ms to reach 3.3 V, so a normal power up never reaches the blanking time. A load with 470 microfarad takes 39 ms and will be treated as a fault, which is the case to catch in the lab rather than in the field.
The latch behaviour after a fault is the difference between this member and the auto restart variants. Once the 10 ms window expires with the fault still present, the switch opens and the flag goes low, and the switch stays open until the enable is toggled. A host that wants a retry policy implements it in firmware, with the number of attempts and the delay under its own control. That is the right behaviour for a port where a permanent short should not produce an endless hiccup that heats the board and hides the fault from the operator.
The on resistance is high by the standards of a power switch, and the reason is that the part is built for a small current. At 0.5 Ohm and 40 mA the drop is 20 mV and the dissipation is 0.8 mW, which is negligible, and the same body at a 1 A load would be dissipating half a watt. The 40 mA limit means the part can never see the current that would make the resistance a problem, and that is the trade the family makes: a cheap five pin body with a limit that protects the load rather than a low resistance path that would let a fault draw real current.
- The current limit window against the normal load, because 40 to 80 mA is a two to one spread.
- The output capacitance against the 10 ms blanking, since a large capacitor looks like a fault at power up.
- The latch behaviour and the firmware retry policy, because this member does not restart on its own.
- The flag pull up, since the open drain output reports three different conditions on one pin.
- The enable threshold at the actual logic rail, which the vendor prints for each input voltage.
- The under voltage lockout, 1.32 to 1.52 V rising, for any product whose rail decays slowly.
Which projects this part fits
This part fits low current sensor protection on instrument front ends, HDMI and connector protection where a 5 V pin can be shorted by a cable, notebook and PDA peripheral ports, GPS and media player accessories, and any board where a port has to be protected at tens of milliamps without a controller and an external FET. The SC-70 body and the UL recognition make it a practical choice for a product that has to show a safety file.
Questions that come up before a purchase order is released
What happens after the switch latches off?
It stays off until the enable pin is driven low and then high again, or until the input supply is cycled. The flag stays asserted while the fault is present and releases when the switch is re enabled and the load is healthy, so the host can distinguish a latched port from a live one.
Can I change the current limit?
Not on this part. The 40 mA level is fixed inside the die, and the 100 mA level is a different member of the same family with the same footprint. If a product needs a selectable limit, the family with a limit select pin is the one to use, not this one.
Why does the flag also report undervoltage?
Because a supply that is too low to control the switch is a fault condition for the load, and the part treats it the same way as a current limit. The flag is a single open drain pin that goes low for current limit, undervoltage and thermal shutdown, so the host has to look at the rail to tell which of the three it is.
Is 30 microseconds rise time fast enough to be a problem?
Into 0.1 microfarad it is, because the inrush is limited by the current limit rather than by the switch. The part moves into constant current as soon as the load exceeds the limit, so a fast rise into a large capacitor becomes a 10 ms current limited charge rather than a spike. The blanking window is what decides whether that charge is treated as a fault.
What is the difference between this member and the auto restart one?
Only the restart behaviour and, on some members, the limit level. This one latches, the auto restart members retry after about 80 ms. The footprint and the pin out are identical, so a board can change policy with a part number change, but the firmware has to know which one is fitted.
How SUPERB handles this line
We supply the TPS22943DCKR on original 3000 piece reels with the marking and date code recorded, and we can supply the auto restart and 100 mA members of the same family when a board changes its fault policy without changing its footprint. The power management cross reference page lists the limited switches by level, blanking and restart behaviour, BOM consolidation covers the case where a product family uses two members of this line, and kitting service is how we deliver these parts against a build.