Contact Us

TPS2069CDBVR

Brand: Texas Instruments
Texas Instruments TPS2069CDBVR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS2069CDBVR — Power Management & Signal Chain | Superb Automation

TPS2069CDBVR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS2069CDBVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS2069CDBVR: 1 A fixed limit power switch with fast overcurrent response

TPS2069CDBVR is a single channel 1 A fixed current limit power switch in a SOT-23 body of 5 pins. It is the 1 A member of the same family, sharing the body and marking scheme with the 0.5 A and 2 A parts.

Order code and package

Order codeTPS2069CDBVR, DBV package, 3000 pieces on a large reel
BodySOT-23, 2.90 mm by 1.60 mm, five leads
Rated current1 A continuous, limit centred at 1.55 A
EnableActive high
FamilyTPS20xxC and TPS20xxC-2, rated at 0.5 A, 1 A, 1.5 A and 2 A

Electrical parameters that decide the application

Input range4.5 V to 5.5 V for the specified limits
On resistance96 mOhm typical and 110 mOhm maximum at 25 C, 96 mOhm typical and 130 mOhm maximum over temperature
Current limit1.3 A minimum, 1.55 A typical, 1.8 A maximum for the 1 A rated output
Overcurrent response2 us typical from the application of the short to the current falling
Reverse leakage1 uA maximum with the output above the input and the device disabled
ThermalJunction to ambient 224.9 C/W in the five lead SOT-23
Fault flagOpen drain active low, deglitched, asserted on overcurrent and overtemperature

Family variants and how they differ

TPS2068CSame 1 A rating with an active low enable
TPS2069C-2Same rating with the output discharge option, which pulls the output down at turn off
TPS2051C0.5 A member, same body, limit centred at 0.85 A
TPS2069D1.5 A part in a separate document with an under voltage lockout at 3.5 V to 4 V
TPS2561Two channels of adjustable limit when one fixed 1 A threshold does not fit both ports

Points to check before this part goes on a BOM

At 1 A the SOT-23 body is close to its practical ceiling. The 96 mOhm typical and 130 mOhm maximum give 96 mV and 130 mV of drop, and 96 mW to 130 mW of dissipation. With 224.9 C/W junction to ambient, 130 mW raises the junction by 29 C above the board, so a 70 C ambient puts the die at 99 C and leaves 26 C of margin to the 125 C limit. The margin is real but it is not large, and it disappears if the part sits next to a regulator.

The limit window of 1.3 A to 1.8 A is what the upstream supply has to survive. A 5 V supply rated at 1.5 A continuous will be pushed above its rating on a part at the top of the window, and a supply with a hard current limit below 1.8 A may fold back before the switch reaches its own limit, which turns a port fault into a rail collapse. The two limits have to be ordered, not chosen independently.

The 2 us response is the figure that keeps the rail up. It describes how long the output current takes to fall after a short is applied at the far end of a cable, and it is short compared with the loop bandwidth of most 5 V regulators. What it does not describe is the energy in the cable inductance, which is dumped into the switch and the load capacitance before the limit acts, and a long cable at 1 A stores enough to matter for the connector.

The thermal circuit is the second line, not the first. With a permanent short the switch sits in constant current at 1.55 A and dissipates the input voltage times that current, which is 8.5 W at 5.5 V, until the junction rises by the 135 C trip point. That takes milliseconds in a SOT-23 and is why the part survives a short at all, but it also means the flag is asserted for the whole interval and the host sees a fault that lasts longer than the 2 us response figure.

The output discharge option is the difference between the plain part and the -2. On a port that must be discharged before the next enumeration, the discharge FET removes the residual charge in the load capacitance; without it the port holds its voltage for as long as the load draws no current. This order code is the plain body, so a product that needs the discharge behaviour has to be ordered with the suffix rather than assumed.

Reverse leakage of 1 uA is specified for the disabled state. On a port that is disabled while the far end is powered from another source, the blocking keeps the upstream rail from being lifted, but the 1 uA is a leakage figure and not an isolation rating. A port that needs real isolation needs a switch with a specified off state resistance or a separate blocking device.

The five lead body has no exposed pad. Heat leaves through the three input and output leads and the board copper around them, and the 224.9 C/W figure assumes the JEDEC test board. A real board with a small copper area is worse, so the 29 C rise calculated at 1 A is optimistic on a dense board and the board should either widen the copper at the leads or move down to the 0.5 A member.

Marking and reel format are shared across the family. The 1 A and 0.5 A parts are both five lead SOT-23 in 3000 piece reels, and only the body code and the label separate them. An incoming inspection that checks package outline only will pass a mixed shipment, and the error shows up as a port that trips at the wrong current.

The 224.9 C/W junction to ambient figure is measured on the JEDEC test board with its copper. A real board with a small pad and no plane under the part will be worse, and the datasheet does not give a number for that case. The practical rule is that the three input and output leads are the only heat path, so the copper around them should be as wide as the footprint allows and connected to a plane if one exists on that layer. At 1 A the difference between a good and a poor land pattern is roughly 15 C of junction temperature, which is the difference between comfortable and marginal at a 70 C ambient.

Where this order code fits

It suits a 5 V port or an internal rail that has to carry a full amp, such as a USB charging port, a fan header or a peripheral slot, where the limit has to sit above the load current and below the connector and supply ratings. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the BOM Shortage Recovery page.

Questions buyers ask

Can it carry 1 A at 85 C ambient? The dissipation at the maximum resistance is 130 mW, which is a 29 C rise, so the junction reaches 114 C at 85 C ambient and stays inside the 125 C limit on the JEDEC board.

What is the fault current? Between 1.3 A and 1.8 A over the operating range, centred on 1.55 A.

Does it need an input capacitor? Yes, at least 0.1 uF ceramic close to the input pin, and more bulk if the upstream supply is far away or has a long cable.

Is the flag latched? No, it follows the fault and releases when the overload is removed and the junction has cooled.

What is the drop at 1 A? 96 mV typical and 130 mV maximum over temperature, which is 96 mW to 130 mW in the body.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.