Contact Us

TMP422AIDCNR

Brand: Texas Instruments
Texas Instruments TMP422AIDCNR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TMP422AIDCNR — Power Management & Signal Chain | Superb Automation

TMP422AIDCNR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TMP422AIDCNR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TMP422AIDCNR: two remote diode channels in an eight pin SOT-23

TMP422AIDCNR monitors two remote diode connected transistors plus its own die temperature, and reports all three over an SMBus two wire interface. It is the middle member of the TMP421, TMP422 and TMP423 group: one remote channel on the TMP421, two on the TMP422, three on the TMP423, and the same register map and the same 8-pin SOT-23 body across the three.

The string is chosen when a board has more than one hot device and only one bus. A server with two processors, a telecom line card with two FPGAs, or an instrument with a processor and a power stage can read all three temperatures through one address, which saves an isolator, a bus segment and a set of pull-ups on an isolated board.

The numbers below come from SBOS398C, revised May 2012, and from the package option addendum. They cover the remote accuracy of 1 degree maximum, the local accuracy of 1.5 degrees maximum, the 12-bit resolution, the conversion time of 115 milliseconds per channel, and the fact that the two device addresses are strapped by the diode pins themselves rather than by dedicated address pins.

Addressing without address pins

The 8-pin body has four diode pins, DX1 through DX4, and no separate A0 or A1. Instead the document states that the DX pins also set the device address, and the pin table is explicit about it: each of the four pins both connects a channel and contributes a bit to the slave address. That is how two remote channels and two address bits fit into eight pins.

In practice this means the board arrangement decides the address. A board that ties DX3 and DX4 to ground through short traces yields one address; a board that leaves them floating yields another; a board that pulls them to the supply yields a third. The diode fault detection then tells the host when a channel is open, and the same pin that reports a fault is also the pin that set the address, so a bad solder joint changes both at once. We check that behaviour on the first article of any board that uses this part, because the symptom is confusing: the bus answers at an unexpected address and one remote channel reads as a fault.

The feature list also names multiple interface addresses as a benefit, and that is the point: up to four TMP422 devices can share one bus by strapping the DX pins differently, which gives eight remote channels and four local readings on a single two wire segment.

Channelsone local, two remote diode channels
Remote accuracy1 degree Celsius maximum, 0.25 degrees typical from 15 to 85
Local accuracy1.5 degrees Celsius maximum, 0.25 degrees typical
Resolution12 bits, 0.0625 degrees per count
Conversion time115 milliseconds typical per channel
Conversion rate0.0625 to 8 conversions per second, register selected
Remote rangeup to plus 150 degrees at the diode
Local rangeminus 40 to plus 125 degrees
Supply range2.7 V to 5.5 V, 2.55 V on the C variant
Quiescent current400 microamps typical, 525 microamps maximum
Shutdown current3 microamps typical, 10 microamps maximum
Series resistancecancelled up to 3 k in the recommended circuit
Ideality factorprogrammable, 1.008 default
InterfaceSMBus two wire, up to 3.4 MHz, 30 ms timeout
PackageSOT-23-8, DCN, 3.2 mm by 3.2 mm
Thermal resistance128 degrees per watt junction to ambient
Carrier3000 pieces on a large reel, marking DADI
Moisture levellevel 2 at 260 degrees, one year floor life

Series resistance and the ideality factor

A remote diode is not a perfect diode. The trace from the sensor to the transistor has resistance, the transistor has an ideality factor that is not exactly 1.008, and the current source used to measure the junction has to switch between levels to extract a temperature. The TMP422 handles all three: it cancels series resistance up to 3 k in the recommended circuit, it allows the ideality factor to be programmed through a register at pointer address 21h, and it switches the source current between 6, 12, 60 and 120 microamps to measure at different points on the curve.

The practical consequence is that a customer does not have to route a star connection with matched lengths to get a usable reading. They do have to keep the differential pair together and keep the capacitance below about 2.2 nF, because the error curves in the document show the reading degrading as differential capacitance rises. Beyond that, the part is tolerant of the routing a real board provides.

If the transistor is inside an FPGA or a processor, the vendor publishes an ideality factor and sometimes a beta value. The TMP422 corrects for ideality but has no automatic beta compensation, which is the difference between this family and the TMP431 and TMP432. On a 65 nm or older process the beta is high enough that the omission does not matter. On a 28 nm or finer process the beta falls and the error grows, and that is exactly the case where the TMP43x family is the correct choice rather than this string.

Conversion rate, current and the trade with resolution

The conversion rate register sets how often the part measures, from 0.0625 conversions per second up to 8. The quiescent current scales with that rate: the document's typical curve runs from about 90 microamps at the slowest rate to about 400 microamps at 8 conversions per second on a 5.5 V rail. In shutdown the part falls to 3 microamps typical, and it still answers the bus, so a host can poll a sleeping sensor and wake it with a single register write.

Conversion time per channel is 115 milliseconds typical. At the fastest rate the part is measuring almost continuously across three channels, which is why the current rises. At one conversion per second the duty cycle is a third of that and the current falls accordingly. For a thermal protection loop on a power amplifier a one second update is usually enough; for a processor throttle loop the fast rate is the correct setting and the current is still under half a milliamp.

Resolution is fixed at 12 bits on all three channels, so the trade is between update rate and current, not between rate and resolution. That is a simpler choice than on the digital families where the resolution register also changes the conversion time.

Diode fault detection and what it reports

Each remote channel has a fault detector that reports an open or a short on the diode pair. An open circuit is the common field failure: a cracked solder joint, a connector that has been disturbed, or a transistor that was never placed. A short is rarer and usually means a solder bridge between the two pins of the pair. The status register reports which channel faulted, and the part keeps the other channels running, so a two channel board loses one reading rather than the whole sensor.

The fault threshold is set by the source current and the forward voltage window, and the document's electrical table gives the limits. In our experience the detector catches an open pair reliably and can miss a resistive joint in the hundreds of ohms range, which is why the series resistance cancellation figure of 3 k is worth remembering: a joint that adds 200 ohms changes the reading by less than the accuracy of the part, so the fault detector is the only signal that something is wrong.

Where the two channel part earns its place

The document lists processor and FPGA temperature monitoring, LCD, DLP and LCOS projectors, servers, central office telecom equipment and storage area networks. On our side the string turns up in telecom line cards with two hot devices, in instrument clusters where a processor and a power stage share one bus, and in medical imaging front ends where the analog chain has to stay quiet and a two wire bus with a slow clock is easier to keep quiet than a fast one.

For a board that also carries an RF chain, the sensor is a convenient way to watch the temperature of a power amplifier die that already has a diode brought out, since the remote channel measures the die rather than the board. That use is common in our RF builds, and the RF component sourcing page lists the parts we hold for that class of assembly.

The alternative is a digital sensor per hot device, which costs an address, a package and a placement each. The two channel part trades that for one package and one address, and it adds the local reading for free. The pin to pin cross reference page covers the case where a customer wants to move from the TMP421 to this string: the body is the same, the register map is a superset, but the diode pins carry address bits, so the board arrangement has to be checked before the swap is approved.

Three questions buyers ask about this string

Does it need a calibration? No. The remote accuracy of 1 degree maximum is specified without calibration, and the ideality factor register is there to match the transistor, not to trim the part.

Can the two channels measure the same transistor? They can, but there is no benefit. The channels are independent and the fault detectors would report the same condition twice.

What happens if the diode pair is left open? The channel reports a fault, the other channel and the local sensor keep working, and the part continues to answer the bus. That behaviour is what makes the string usable on a board that cannot be serviced, and it is why we keep the part in stock for telecom builds rather than substituting a single channel device.