TMP390A2DRLR
Product Specifications
TMP390A2DRLR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TMP390A2DRLR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TMP390A2DRLR dual channel hot and cold temperature switch at half a microamp in SOT-563
The TMP390A2DRLR is a two channel temperature switch that watches for a hot condition and a cold condition at the same time, each with its own resistor programmable threshold and its own open drain output. Channel A covers thirty to one hundred twenty four degrees in two degree steps, channel B covers minus fifty to plus twenty five degrees in five degree steps, and the two E96 resistors on the set pins choose the trip points from a printed table. Because the resistors are one percent parts and their tolerance contributes no error, the threshold accuracy is the device accuracy and nothing else.
What makes this part interesting is the current: half a microamp typical and one microamp maximum at twenty five degrees on a 1.62 to 5.5 V supply, with a standby figure of a quarter of a microamp. A product that has to hold a thermal watch for years on a coin cell can do it with this device and a pair of resistors, and the part still offers a trip test function so the threshold can be exercised in system during production without changing the temperature of the board. Three hysteresis settings are available, five, ten and twenty degrees.
Key parameters taken from the TMP390A2DRLR document
| Channels | channel A overtemperature, channel B undertemperature, independent outputs |
| Threshold range A | 30 to 124 C in 2 C steps, set by an E96 resistor from 1.05 to 909 kilohms |
| Threshold range B | minus 50 to plus 25 C in 5 C steps, set by an E96 resistor from 10.5 to 909 kilohms |
| Threshold accuracy | A2 grade, plus or minus 1.5 C from 0 to 70 C at 2.5 to 5.5 V, plus or minus 3.0 C over minus 55 to 130 C at 1.62 to 2.5 V |
| Hysteresis | 5 C or 10 C from the channel B resistor selection, 20 C on channel A when the channel B pin is grounded |
| Supply | 1.62 to 5.5 V, 3.3 V typical |
| Current | 0.5 microamp typical and 1 microamp maximum average, 0.25 microamp standby, 135 microamp during a conversion |
| Timing | conversion duration 0.65 ms, sampling period 0.5 s |
| Outputs | open drain, active low, 0.4 V maximum low level at 3 mA, pull up to the supply plus 0.3 V at most |
| Test function | trip test activates the outputs by exercising the set pins, for in system verification |
| Package | SOT-563, body DRL, 1.60 by 1.20 mm, six pins |
| Order code facts | TMP390A2DRLR, SOT-5X3 DRL 6 pins, 4000 pieces on a large reel, NIPDAUAG, Level-2-260C-1 YEAR, minus 55 to plus 130 C, marking 1C4, Active |
The table above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for the first article.
Where the numbers matter in a real build
The cold channel is the one that gets forgotten, and it is the reason this part exists in outdoor equipment. A lithium cell loses most of its capacity below minus twenty, an LCD stops responding, and a heater has to come on before the product is asked to work. Channel B covers exactly that range and it has its own output, so the heater control and the over temperature protection do not have to share a decision. A product that only reads the hot output leaves the cold case unhandled, which shows up as a field return from a northern site and nowhere else.
The resistor table is the whole configuration, and the parts have to be E96 one percent types from the printed list. A value from the E192 series that happens to be close will select a different row and therefore a different threshold, and the error is silent because the part still switches, just at the wrong temperature. The practical rule for production is to place both resistors from the table image on the assembly drawing rather than from a note, and to check them with a meter on the first article against the table.
Half a microamp is a real number only if the rest of the circuit does not spend more. The outputs are open drain and the pull ups are the load: a 100 kilohm pull up on a 3.3 V rail draws 33 microamps whenever the output is low, which is sixty times the device current. A product built around the low current of this switch should use the largest pull up the receiving input can tolerate, and should switch the pull up rail if the signal is only read during a wake window.
The trip test function is what makes this part attractive for production. Asserting the set pin forces the output without heating the board, so a bed of nails or a functional test can verify the whole path from the switch to the processor input in seconds. The document describes the method and the limits, and the test has to be planned into the fixture before the board is released, because adding a probe point afterwards usually means a new fixture rather than a new test step.
- Both channels exercised through the trip test at the fixture, with the output state read at the processor pin.
- Threshold measured on the real board at one temperature with the resistors in place, compared against the table row.
- Output pull up value and the resulting low level with the real load, since the open drain rating is 3 mA.
- Current draw in the standby state, measured with the pull ups powered, which is where the microamp budget is usually lost.
- Cold channel behaviour at the lowest temperature the product will see, including the heater turn on point.
- Hysteresis verified by sweeping through the threshold in both directions to confirm the gap that was selected.
Which projects this part fits
This switch fits outdoor and battery powered equipment: remote radio units and edge routers, wireless access points, power banks, DC to AC inverters, DC to DC converters, power tools, environmental control systems, temperature transmitters and any product that has to survive a cold start and a hot cabinet without a processor awake. It is also used as the safety backstop behind a digital sensor, because a firmware update cannot change a resistor.
Questions that come up before a purchase order is released
How is this different from a digital temperature sensor?
It has no bus and no register map for the measurement, so there is nothing to poll and nothing to configure at run time. The threshold is set in hardware by two resistors and the result is a logic level. A digital sensor tells a processor what the temperature is, this part tells the hardware that a limit has been crossed, and a product usually needs the second one for protection and the first one for reporting.
Can both channels be used with the same resistor value?
The two set pins have different ranges and different step sizes, so the same value lands on a different temperature on each channel. Channel A goes from 1.05 to 909 kilohms across its range and channel B from 10.5 to 909 kilohms, and the table in the document gives the exact pairing. Reading the table per channel is the only safe method.
What does the twenty degree hysteresis setting require?
It applies to channel A only, and it is selected by connecting the channel B set pin to ground. That removes channel B from service, so a product that needs a cold threshold cannot use the twenty degree setting at the same time. The choice is between a wide hot hysteresis and a working cold channel, and the document prints both cases.
Is the supply range suitable for a 5 V system?
Yes, the device runs to 5.5 V and the outputs can be pulled to the supply plus 0.3 V at most, so a 5 V rail works for both the supply and the pull ups. On a 12 V system the outputs cannot be pulled to 12 V, and a small transistor or a divider is needed between the switch and the load.
Why is the reel 4000 pieces?
Because the body is 1.6 by 1.2 mm and the vendor packs it densely. The moisture class is level 2 with a one year floor life, which is more forgiving than the level 3 parts in this family, and the small body size means the pick and place nozzle and the placement accuracy have to be checked before the first run.
How SUPERB handles this line
We supply the TMP390A2DRLR on the original 4000 piece reel with date code and lot traceability, and for a prototype we can supply from a cut reel without losing the label. The body is small enough that placement and reflow need a check on the first article, and we record the result with the build. The drone and UAV components and power management cross reference pages cover the neighbouring parts of a protection chain, and the incoming inspection plan page describes how we verify a switch that cannot be calibrated in the field.