Contact Us

TLC27L2IDR

Brand: Texas Instruments
Texas Instruments TLC27L2IDR is a power management component designed for general electronics and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TLC27L2IDR — Power Management & Signal Chain | Superb Automation

TLC27L2IDR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TLC27L2IDR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TLC27L2IDR: dual LinCMOS operational amplifier drawing 20 microamps, industrial temperature, on tape and reel

TLC27L2IDR is a dual CMOS operational amplifier that consumes 10 microamps per amplifier and holds a 10 millivolt offset across a minus 40 to 85 C span in a SOIC body of 8 pins. The I suffix fixes the temperature range at minus 40 to 85 C and the DR suffix is the 8 pin SOIC on tape and reel. The two amplifiers together draw 20 microamps typical and 34 maximum at 5 V, the input common mode reaches 0.2 V below the negative rail, and the input resistance is 10 to the twelfth ohm. Supply range is 4 to 16 V on this grade, and the D body dissipates 725 mW at 25 C.

Order code and package

Order codeTLC27L2IDR
Functiondual operational amplifier, LinCMOS, single supply
PackageSOIC, 8 pins, body code D, tape and reel
Supply range4 to 16 V, 18 V absolute maximum
Supply current20 microamps typical, 34 maximum for both amplifiers at 5 V
Input offset voltage1.1 mV typical, 10 mV maximum at 25 C
Input resistance10 to the twelfth ohm typical
Offset drift1.1 microvolts per degree average
Output currentplus or minus 30 mA absolute maximum
Dissipation725 mW at 25 C, 377 mW at 85 C, D body
Temperature rangeminus 40 to 85 C, I suffix
Long term stability0.1 microvolt per month including the first 30 days
DatasheetSLOS052E, revision of July 2025

Electrical parameters that decide the application

Input offset voltage1.1 mV typical, 10 mV maximum at 25 C, 13 mV over the range
Offset drift1.1 microvolts per degree average from 25 to 85 C
Input bias current0.6 picoamps typical, 60 maximum at 25 C, 2000 at 85 C
Input offset current0.5 picoamps typical, 60 maximum at 25 C, 1000 at 85 C
Common mode rangeminus 0.2 to 4.2 V typical on a 5 V rail, 3.5 V guaranteed
High output level3.2 V minimum at 4.1 typical, 1 megohm load
Low output level150 mV at no load current
Large signal gain50 V per mV minimum, 480 typical
Common mode rejection65 dB minimum, 87 typical
Supply rejection70 dB minimum, 97 typical
Supply current over temperature31 microamps typical and 48 maximum at minus 40 C
Unity gain stabilityinternally compensated, output includes the negative rail

Points to check before this part goes on a BOM

Ten millivolts of offset is the plain TLC27L2 grade, not the trimmed one. The same datasheet offers the TLC27L2A at 0.95 mV typical and 7 mV maximum over the range, and the TLC27L2B at 2 mV maximum at 25 C, so a circuit that needs a millivolt of accuracy is on the wrong order code and no amount of trimming at test will fix the drift.

The bias current is the headline and it moves with temperature: 60 picoamps maximum at 25 C becomes 2000 picoamps at 85 C, a factor of thirty three. Into a 10 megohm source that is 0.6 mV at room temperature and 20 mV hot, so the high impedance front end has to be evaluated at the hot end and not at the bench.

The common mode range extends 0.2 V below the negative rail, which is what allows a single supply sensor front end to sense at ground. The top of the range is the limit: 4.2 V typical on a 5 V rail and 3.5 V guaranteed, so a signal that swings to the positive rail is outside the window and the datasheet output stage, not the input, becomes the clip point.

Supply current of 20 microamps is quoted for both amplifiers at 5 V and rises to 31 microamps at minus 40 C. That temperature coefficient is the opposite of what a battery product wants, and it is why the standby current budget for an outdoor transmitter is taken at the cold end.

The output stage includes the negative rail, so a follower can drive down to ground without a negative supply. Sinking current is limited though: the low level is 150 mV at no load and the 30 mA absolute maximum is a survival rating, so a 10 kohm load is the sensible operating point for this part.

Long term stability of 0.1 microvolt per month is a drift specification, and it is not the same as the temperature coefficient. A product calibrated once in production and expected to hold for ten years accumulates 12 microvolts, which is small against the 10 mV offset but larger than the 1.1 microvolt per degree term over a 10 degree swing.

Where this order code fits

Battery and loop powered instruments are the home ground: smoke and heat detectors, 4 to 20 mA field transmitters for pressure, flow, level and temperature, and any sensor front end that has to run for years from a lithium cell. The bias current of 60 picoamps maximum at 25 C is what makes a 10 megohm bridge or a pH electrode usable without a buffer stage in front. Boards comparing it with a neighbouring part start from our Amplifier Cross Reference page, and boards replacing a part that has gone end of life start from the Medical Device Components page.

Questions buyers ask

What is the real supply current per amplifier? About 10 microamps at 5 V and 25 C, 17 microamps at minus 40 C for the pair, and the maximum is 34 microamps for the pair over the range.

Can it drive a 10 megohm sensor directly? Yes, and that is what the part is for, but the bias current at 85 C is 2000 picoamps, which is 20 mV into 10 megohm. The error at temperature is larger than the offset and has to be budgeted separately.

How does it compare with the TLC27M2? Same family, different bias. The L version is the micropower one at 10 microamps and 0.05 MHz, the M version is 2.1 mW with a 525 kHz bandwidth, so the choice is power against speed and nothing else.

SUPERB holds and sources this Texas Instruments line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a line is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.