SN65LBC176QDRQ1
Product Specifications
SN65LBC176QDRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The SN65LBC176QDRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
SN65LBC176QDRQ1: the automotive release of the LBC176 bus transceiver
The SN65LBC176QDRQ1 is the automotive qualified version of the SN65LBC176 differential bus transceiver: a 5 V part that combines a three state differential driver and a differential input receiver on one pair of bus terminals, meeting TIA/EIA-485-A and ISO 8482:1987(E). The Q1 suffix marks the automotive release, which carries its own qualification file, its own temperature band and its own production part approval process.
Functionally it behaves like the industrial member. Receiver sensitivity is plus or minus 200 mV maximum with 50 mV of typical hysteresis, the driver delivers at least 1.5 V differential into a 54 ohm load with current limiting in both directions, the disabled supply current is 200 uA maximum, and the receiver is fail safe on an open circuit. The difference is the qualification route and the documentation that comes with it.
Key data for the SN65LBC176QDRQ1
| Qualification | Automotive Q1 release with its own qualification file, separate from the industrial and extended temperature rows |
| Standard | TIA/EIA-485-A and ISO 8482:1987(E), bidirectional multipoint transmission on one pair |
| Receiver | Plus or minus 200 mV sensitivity maximum, 50 mV typical hysteresis, open circuit fail safe |
| Driver | At least 1.5 V differential into 54 ohm, current limited in both directions, thermal shutdown |
| Power | Disabled supply current 200 uA maximum, high impedance on the bus when disabled or unpowered |
| Bus | Wide positive and negative common mode range for party line operation in noisy harnesses |
Body, marking and reel data
| Body | D, SOIC 8 at 4.90 mm by 3.91 mm, the same outline as the industrial member |
| Reel | 2500 pieces on a large reel for the industrial rows of this family, carrier tape 12.0 mm |
| Marking | The industrial rows print 7LB176 and 75LBC176, and the Q1 row follows its own marking table in the automotive document |
| Addendum status | The current industrial revision publishes QDR, QDR.A and QDRG4, and does not print a Q1 row at all |
| Documentation | The Q1 release is documented separately, so the qualification file has to come from that document rather than from the industrial one |
Where the automotive release changes the paperwork
A vehicle module has to show a qualification file that matches the part it buys: AEC-Q100 grade, temperature band, ESD classification and production part approval evidence. An industrial part with the same die does not carry those documents, and a module built with one cannot be signed off even if it works on the bench. That is the whole reason the Q1 row exists separately, and it is why the price and the lead time differ. The qualification file also fixes the change control: a mask change or a test site move on a Q1 line is reported, while an industrial line can move without telling the buyer, and that difference is what a module qualification is built on.
The functional side stays familiar. A bus that was built around the LBC176 receiver thresholds and drive levels behaves the same way, so the change from an industrial row to a Q1 row does not move the termination, the cable or the protocol. What moves is the traceability: lot, date code and qualification record come with the shipment. A production part approval file written around the industrial row has to be reopened when the automotive row is introduced, even though the die is the same, because the document set behind the part is different.
Questions we get when this code is on a BOM
The first question is whether the Q1 string is published in the industrial datasheet. It is not. The revision we have prints the QDR, QDR.A and QDRG4 rows plus the ceramic SNJ55 parts, and the Q1 release lives in a separate automotive document. A buyer who checks the industrial addendum, finds no Q1 row and concludes the part does not exist is reading the wrong file, and a buyer who assumes the rows are equivalent is making a different mistake. We confirm the qualification document before quoting.
The second question is about the temperature band. The Q member of the industrial family prints minus 55 C to 125 C, and the automotive grade of a similar part is often minus 40 C to 125 C. The two are not the same claim, so a build that needs the wider band cannot simply take the automotive row, and a build that needs the automotive paperwork cannot take the wider band part. We ask which of the two the module actually needs.
How SUPERB supports this line item
We quote the SN65LBC176QDRQ1 with the qualification route named and the supporting document identified, because the industrial addendum does not print this row. Customers comparing the automotive and extended temperature members can use our pin to pin cross reference page and our supplier quality audit page, which sets out the traceability evidence we collect on automotive lines.
For modules that have to keep a qualification file complete across a part change, the sourcing audit trail page describes the record we keep from quote to shipment.