SN6505BQDBVRQ1
Product Specifications
SN6505BQDBVRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The SN6505BQDBVRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
SN6505BQDBVRQ1: 1 A transformer driver at 420 kHz for isolated supplies, automotive grade
SN6505BQDBVRQ1 is a push pull oscillator with two 1 A switches, built to drive the primary of a centre tapped transformer and make an isolated rail without a controller, a gate drive loop or a current sense in a SOT-23 body of 6 pins. It runs from 2.25 V to 5.5 V, drives 1 A at a 5 V supply through switches with 0.25 ohm maximum on resistance at 4.5 V, oscillates at 420 kHz on the B member against 160 kHz on the A, and adds spread spectrum clocking plus slew rate control to keep emissions low. The protection set is a 1.7 A current limit, an under voltage lockout at 2.25 V rising and 1.7 V falling, thermal shutdown, break before make logic, and a soft start that limits inrush into a large output capacitor. Shutdown current is under 1 uA and the temperature range is minus 55 to plus 125 degrees.
Order code and package
| SN6505BQDBVRQ1 | the catalogue string on this page: six pin SOT-23, 420 kHz, automotive Q100 grade. The rows printed in this document are the industrial SN6505B strings, so the Q1 packing has to come from the automotive addendum |
| SN6505BDBVR | SOT-23 DBV body, 6 pins, Active, 3000 pieces on a large reel, NIPDAU finish, moisture level 1 with unlimited floor life, minus 55 to plus 125 degrees, marking 650B or 65BQ |
| SN6505BDBVT | the same body on a 250 piece small reel, which is the row for a prototype or a repair order |
| SN6505A | the 160 kHz member of the same family, for a transformer that is already qualified at that frequency or for a rail where emissions near 400 kHz are a problem |
| SN6501 | the smaller five pin driver with 350 mA of primary current at 5 V, no enable, no soft start and no spread spectrum. The 6505 is the part when the rail has to be switched off or the emissions have to be spread |
Electrical parameters that decide the application
| Input range | 2.25 V to 5.5 V, which covers a 3.3 V rail, a 5 V rail and a lithium cell that falls to 2.5 V near the end of discharge |
| Output drive | 1 A at a 5 V supply through two internal switches, and 0.25 ohm maximum on resistance at 4.5 V, which is the loss term that decides how much of the input reaches the transformer |
| Switching frequency | 420 kHz on the B member, double the 160 kHz of the A. The higher frequency allows a smaller transformer for the same power and moves the switching products higher, which is a filtering decision |
| Spread spectrum | clock spreading on this family, which trades a small amount of jitter for a lower peak emission. A rail that has to pass a conducted emissions limit at the switching frequency is the reason to choose it |
| Current limit | 1.7 A, above the 1 A drive rating, so a transformer with a low primary resistance can be driven to the rating without the limit folding back on every cycle |
| Lockout | 2.25 V rising and 1.7 V falling with 0.3 V of hysteresis, so a rail that sags under load turns the driver off cleanly rather than oscillating at the threshold |
| Soft start | an internal ramp that limits inrush into the output capacitor, which is what stops a 10 uF secondary capacitor from looking like a short at power up |
| Break before make | an internal gap between the two switches, the timing that stops both halves of the primary conducting at once and saturating the transformer |
| Shutdown | under 1 uA with the enable pin pulled low, so an isolated rail can be parked in standby without a load switch |
| Synchronisation | a clock input so several drivers can run from one clock, which is how a multi rail board avoids intermodulation between two isolated supplies |
| Thermal shutdown | an internal junction limit that protects the switches during a secondary short |
| Temperature | minus 55 to plus 125 degrees, wider than the minus 40 to plus 125 of the SN6501, and the reason it appears on under hood and outdoor modules |
Family variants and how they differ
| B against A | 420 kHz against 160 kHz on the same die and the same pinout. The B allows a smaller transformer and the A sits lower in frequency where a larger, cheaper core still works |
| 6505 against 6501 | the 6501 is five pins, 350 mA and no enable or soft start. The 6505 adds the sixth pin, the higher current, the enable, the soft start and the spread spectrum |
| Against an isolated module | a DC to DC module needs no transformer, carries its own certification and costs three to five times as much board area. The driver plus transformer wins when the output voltage or the barrier has to be chosen |
| Against a flyback controller | a controller with an external FET handles far more power and needs a compensation network, an opto or a third winding for feedback. This part is the smallest complete answer below about 5 W |
| Against a charge pump | a charge pump cannot hold a barrier and cannot deliver the tens of milliamps an isolated interface draws, so it is not a substitute in this slot |
Points to check before this part goes on a BOM
The transformer decides the rail, not the driver. The output voltage follows the turns ratio and the rectifier drop, the isolation follows the transformer and the spacing, and the current follows the primary winding resistance. The driver only sets the switching frequency and the drive. A quote that promises a barrier voltage against SN6505B is describing a component the part does not contain, and a test house will ask which device provides it.
The 420 kHz choice is a size decision with an emissions consequence. A smaller transformer means a smaller board and a higher switching frequency, and the switching products move from a band where a simple LC filter works to one where the copper of the rectifier loop matters. A board that passes with the A member can fail with the B for that reason alone, and the fix is in the copper, not in the part.
The B version is not simply a faster A version for every customer. If the transformer on the existing bill of materials was chosen for 160 kHz, its core losses at 420 kHz are higher and its temperature rise changes. A substitution in either direction needs the transformer re checked against its own data, and that check is where most field failures of this kind start.
The 1 A drive rating is the switch current, not the output current. At a 1 to 1 ratio and 5 V in, that is about 1 A of secondary current before losses, and with a 1 to 2 step up the same primary current buys half the output current at twice the voltage. Power is the conserved quantity, and a customer who asks for 5 W from a 3.3 V input is outside what the switches can carry.
The Q1 grade string on this page carries the automotive qualification and this document prints the industrial rows. The electrical behaviour is the same, the packing and the qualification documentation are not, and a production order for a vehicle programme needs the automotive addendum to state the reel size and the traceability.
The enable pin is not a soft stop. Pulling it low stops the switches and the secondary rail collapses at the rate the load and the output capacitor allow, with no active discharge on this part. A product that needs the isolated rail to fall in a defined time needs a discharge path on the secondary, and that is a component on the board rather than a feature of the driver.
Where a 420 kHz driver saves board area
A push pull transformer at 420 kHz needs roughly a third of the core volume of the same power at 160 kHz, and the output capacitor falls with it because the ripple frequency is twice the switching frequency. On a module that has to fit behind a connector, that difference is what makes the isolated rail possible at all.
The price is that the rectifier loop becomes the critical copper. At 840 kHz of ripple, a 5 mm loop with a poor return path radiates and couples into the adjacent analog section, and the fix is a tight loop and a ground plane rather than a different part. Boards that were built for the 160 kHz member and then changed to the 420 kHz one usually need that copper change.
What the order code decides
The string reads SN6505 for the device family, B for the 420 kHz oscillator, Q for the automotive qualification, DBV for the six pin SOT-23 and R for the large reel, and Q1 for the Q100 grade. The A member with the same outline is the 160 kHz version, and the SN6501 is a different die in a five pin body. None of the suffixes changes the drive current, the lockout or the protection set.
Where this order code fits
Isolated supplies for CAN, RS-485, RS-422, RS-232, SPI and low power LAN, plus isolated USB, process control, telecom and medical instrument rails are the applications the vendor prints, and a module that has to keep an interface alive across a barrier on a small board is the case this part is bought for. Teams comparing it with a neighbouring part start from our Component Lead Time Solutions page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.
Questions buyers ask
What is the difference between SN6505A and SN6505B? The internal oscillator: 160 kHz for the A and 420 kHz for the B. The B allows a smaller transformer and moves the switching products higher, which changes the filtering and the copper.
Can it deliver 5 W? At 5 V in it drives 1 A into the primary, which is about 5 W before losses at a 1 to 1 ratio, so the practical ceiling is below that once the switches and the transformer are counted.
Is the reel size published here? The rows in this document are the industrial SN6505B strings at 3000 pieces on a large reel. The Q1 packing sits in the automotive addendum and has to be confirmed for a vehicle programme.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.