Product Specifications

ISO721DR — Power Management & Signal Chain | Superb Automation

ISO721DR

Texas Instruments — Power Management & Signal Chain

Product Overview

The ISO721DR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO721DR: The 100 Mbps Single Channel Isolator With TTL Thresholds and an Input Filter

ISO721DR is a single channel high speed digital isolator with an input noise filter in a SOIC (D-8) body of 8 pins. It carries one line at 100 Mbps with a 12 ns typical delay, uses TTL thresholds so a 3.3 V driver can feed it directly, and keeps the input noise filter that blocks pulses of up to 2 ns before they reach the barrier.

Order code and package

Ordering stringISO721DR
Status in the addendumActive at 2500 pieces on a large reel
Finish and moisture columnsPrinted as Call TI on the plain row, filled in on ISO721DR.A as NIPDAU level 1
Obsolete siblingISO721D is printed Obsolete with no quantity
PackageSOIC, 8 pins, D body
Carrier2500 pieces on a large reel
Temperature rangeMinus 40 to plus 125 degrees Celsius
Part markingISO721
Input thresholdTTL
Input noise filterYes, blocks pulses of up to 2 ns

Electrical parameters that decide the application

Signaling rate100 Mbps
Propagation delay12 ns typical
Pulse skew0.5 ns typical
Isolation rating2500 VRMS for one minute per UL 1577, tested at 1.2 times for one second on every unit
Maximum repetitive peak voltage560 VPK
Maximum transient voltage4000 VPK per VDE 0884-17
External clearance4 mm in the D package
External creepage4 mm in the D package
Distance through insulation0.008 mm
Tracking indexAt least 400 V, material group II
Rated mains voltageUp to 150 VRMS at overvoltage category I to IV, up to 300 VRMS at I to III
Barrier capacitanceAbout 1 pF from input to output
Barrier lifeAbout 28 years at the rated working voltage
Supply range3.3 V or 5 V, or any combination of the two
Input tolerance5 V tolerant when the part runs from a 3.3 V rail
Output drive4 mA CMOS
Fail-safe stateOutput driven high when no refresh pulse arrives for more than 4 microseconds
Power dissipation159 mW at 5.5 V with a 100 Mbps input
Output enableNone on this member, the enable belongs to ISO722
Climatic category40/125/21, pollution degree 2

Family variants and how they differ

ISO721DR.AThe same reel quantity with the finish and moisture columns filled in
ISO721DPrinted Obsolete with no quantity, so the reel string is the one that ships
ISO721MDRThe 150 Mbps member with CMOS thresholds and no input filter
ISO722DRThe 100 Mbps member with CMOS thresholds and an output enable
ISO722MDRThe 150 Mbps member with an output enable, for a shared line
ISO6720FBDRA dual at 50 Mbps when a second channel is needed at a lower rate

Points to check before this part goes on a BOM

The 2 ns filter is the feature that separates this part from the M member. It blocks short transients at the input, which is what a fieldbus line in a cabinet needs, and it costs a small amount of delay and jitter that the M member does not pay.

The finish column on the plain row reads Call TI while ISO721DR.A reads NIPDAU at level 1. Both are the same die on the same 2500 piece reel, and the .A string is the one with a published finish, so a purchase order that needs a stated finish should name it.

TTL thresholds are not the same as CMOS thresholds. A TTL input switches at a fixed level around 1.4 V and a CMOS input switches at half the rail, so a 3.3 V logic family drives a TTL input comfortably while a CMOS input on the M member expects the higher relative level.

2500 VRMS with 4 mm of clearance is a basic barrier. The 4000 VPK transient number is a short event and does not turn the part into a reinforced barrier, which is a distinction that decides whether the part can sit across a mains boundary at all.

The fail-safe state is high. When the input side stops refreshing, the output goes high after about 4 microseconds, so a downstream device that reads a high as a command needs the logic inverted somewhere rather than relying on the isolator.

The plain reel row and the .A row print the same 2500 pieces, so the choice between them is about the finish paperwork rather than about availability. A purchase order that names a finish should name the .A string.

Where the filter earns its place

A cabinet full of contactors and drives puts short transients on every cable that leaves the enclosure, and a 2 ns pulse is enough to clock a flip-flop on the far side if nothing blocks it. The input filter on this part is the cheapest place to stop that, because it sits before the barrier rather than after it.

On a clean board the filter is dead weight and the M member is the better part, because the jitter figure matters when the line carries a recovered clock. Choosing between the two is a question about the cable, not about the isolator.

Reading the addendum rows correctly

Four rows carry this part number family with different endings, and only two of them ship. ISO721D is obsolete with no quantity, ISO721DR is active at 2500 pieces with the finish printed as Call TI, and ISO721DR.A is active at 2500 pieces with NIPDAU at level 1.

The practical rule is to quote the reel string, note the marking as ISO721, and keep the .A as the alternate for a purchase order that requires a named finish. That is a paperwork decision, not a technical one, and it should be made before the line is scheduled rather than after the reel lands.

What a 2 ns filter is worth

The filter is a short pulse rejector at the input. A transient shorter than 2 ns does not reach the barrier, which means it cannot set a flip-flop on the far side. On a cabinet full of contactors that is the difference between a link that runs for years and one that needs a watchdog reset every few weeks.

The cost is a small addition to the propagation delay and to the jitter, and the M member exists for the applications where that cost is not acceptable. Choosing between them is a question about the cable and the enclosure, not about the isolator.

Where the part sits in a fieldbus node

A Modbus or Profibus node typically has one line crossing the barrier, and the transceiver on the field side drives it. The isolator sits between the transceiver and the controller, and it is the only part in the path that has to hold the barrier rating.

Because the part is single channel, the node needs one per line. A node with a receive line, a transmit line and a direction control needs three parts, which is why the three and four channel families exist for the same socket.

Where this order code fits

It is chosen where one digital line crosses a barrier at up to 100 Mbps from a 3.3 V driver and the cable or the cabinet is noisy enough that short transients have to be filtered at the input. Teams comparing it with a neighbouring part start from our Incoming Inspection Plan page, and teams replacing a part that has gone end of life start from the How to Verify a Drop in Replacement page.

Questions buyers ask

Why does the finish column say Call TI? The plain row has that placeholder while ISO721DR.A of the same reel prints NIPDAU at level 1. The die and the packing are the same, and the .A string is the one with a published finish.

Can it run at 150 Mbps like the M part? No. This member is rated at 100 Mbps. The 150 Mbps rate belongs to ISO721MDR, which also drops the input filter in exchange for lower jitter.

Does a 5 V input damage a 3.3 V supplied part? No. The inputs are 5 V tolerant when the part runs from a 3.3 V rail, which is what allows a 5 V driver to feed a 3.3 V supplied isolator without a level shifter.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Vendor Consolidation page sets out the checks that keep a substitute from failing on the bench.