Contact Us

ISO6742FDWR

Brand: Texas Instruments
Texas Instruments ISO6742FDWR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ISO6742FDWR — Power Management & Signal Chain | Superb Automation

ISO6742FDWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The ISO6742FDWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO6742FDWR: quad digital isolator with two channels each way and a low default state

ISO6742FDWR is four independent logic channels across a silicon dioxide barrier in a 16 pin wide body SOIC, with two channels in each direction and an enable pin on each side in a SOIC body of 16 pins. It carries 50 Mbps per channel, isolates to 5000 VRMS for one minute per UL 1577 with 7071 VPK of transient and 10000 VPK of surge, and holds plus or minus 150 kV per microsecond of common mode transient immunity typical with a 100 kV per microsecond minimum. Each channel uses 1.6 mA at 1 Mbps, propagation delay is 11 ns typical and 18 ns maximum with 5 V on both sides, the outputs are valid within 300 microseconds of the rail passing the under voltage threshold, and the default state after an input power loss is reached within 0.3 microseconds.

Order code and package

ISO6742FDWRwide body DW package, 16 pins, 10.30 mm by 7.50 mm, two forward and two reverse channels, default low, 2000 pieces on a large reel, NIPDAU finish, moisture level 2 with a one year floor life, minus 40 to plus 125 degrees, marking ISO6742F
ISO6742FDWR.Athe same reel on the re-released row, identical quantity, finish and moisture level, with the same marking
ISO6742DWRthe default high version of the same channel split, which is the part to choose when a high level is the safe state
ISO6741FDWRthree forward channels and one reverse, default low. The most common split for an isolated SPI link, where three signals go one way and one comes back
ISO6740FDWRall four channels in the same direction, default low, for a parallel bus or a set of enable lines

Electrical parameters that decide the application

Rate50 Mbps per channel, which is fast enough for an isolated SPI port at full clock or for a parallel interface that has to cross a barrier
Supplies1.71 V to 1.89 V or 2.25 V to 5.5 V on each side, so a 1.8 V FPGA can talk to a 5 V gate driver through one package with no shifter
Channel splittwo forward and two reverse on this member. The split is fixed in silicon, so a link that needs three forward channels has to move to the 6741
Default statethe F suffix makes the output low when the input side loses power or signal. Without the F the output defaults high, which is the right choice for an active low enable and the wrong choice for a gate drive signal
Current1.6 mA per channel at 1 Mbps, so a four channel part at that rate draws about 6.4 mA on each side, which is the number a low power budget uses
Propagation11 ns typical and 18 ns maximum with 5 V supplies, with a channel to channel skew of 2.6 ns typical and 4.5 ns maximum and a part to part skew of 6 ns maximum
Enable timingdisable within 25.8 ns and enable within 21.1 ns, so a channel can be parked without a long recovery
Start upthe output is valid within 300 microseconds of the rail crossing the under voltage threshold, and the default state holds until then. A controller that starts reading earlier sees the default
Default delay0.3 microseconds maximum from the rail falling below 1.2 V to the default level, which is what makes the fail state predictable on a fast power down
Bus protectionplus or minus 8 kV IEC 61000-4-2 contact discharge across the barrier at system level, which is a board level number rather than a pin rating
Isolation7071 VPK transient, 10000 VPK surge, 2121 VPK repetitive peak and 1500 VRMS working voltage, with more than 8 mm of clearance and creepage and more than 17 um of insulation thickness
CertificationsUL 1577 at 5000 VRMS for one minute, DIN EN IEC 60747-17 for the VDE file, and the IEC 62368-1, 61010-1 and 60601-1 standards, with TUV, CSA and CQC listed
Temperatureminus 40 to plus 125 degrees, ten degrees narrower at the top than the 774x family and wide enough for most industrial cabinets

Family variants and how they differ

6742 against 6741two each way against three forward and one back. An isolated SPI link needs three forward channels for clock, data and chip select and one back for data, so the 6741 is the usual choice and the 6742 is for a UART pair or two bidirectional handshake lines
6742 against 6740the 6740 sends all four channels the same way, which is what a parallel bus or a set of isolated enables needs
F against no Fthe default state. A gate drive signal has to default low so a lost input does not turn a switch on, while an active low enable has to default high so a lost input does not disable the channel. The two requirements point at different strings
Against ISO774xthe 774x family reaches 100 Mbps and minus 55 to plus 125 degrees, and offers a smaller QSOP body whose isolation figures are much lower. The 674x family is the wide body, 50 Mbps, lower cost option
Against an optocoupleran optocoupler ages, needs a drive current of milliamps per channel and is slower. A capacitive isolator removes the ageing mechanism and the current, at the cost of a different failure mode: it needs a supply on both sides

Points to check before this part goes on a BOM

The default state is the feature that decides whether this part is safe in a given circuit. With the F suffix the output goes low when the input side loses power, which is what a gate drive or a chip select needs. On a channel that drives an active low enable, the same behaviour turns the block off, and the non F string is the correct part. A bill of materials that names one string for all four channels without checking the polarity of each signal is a common source of a product that behaves differently on power down than on power up.

The 5000 VRMS figure is the UL rating for one minute, and the number that matters for a mains referenced product is the working voltage, 1500 VRMS, with 2121 VDC printed for the DC case. The two numbers are not interchangeable, and a customer who sizes a barrier from the one minute rating alone will be outside the standard the product claims.

The enable pins are on both sides, so either side can park the outputs in high impedance. That allows two masters to share a bus, which is the reason the pins exist. The cost is start up time: enabling a channel takes up to 21.1 ns, and after a rail event the outputs are not valid for 300 microseconds, so a controller that comes out of reset faster than that has to wait.

The moisture level is 2 with a one year floor life, not level 1. A reel that sat open in a store over a shutdown needs a bake before reflow, and a process card that assumes level 1 for every isolator on the board will be wrong for this family. The 774x rows in the sister document carry the same level 2, so the whole isolated logic line needs the same process rule.

The functional safety documentation is offered for this family, which matters to a customer building a machine that has to be assessed to a safety integrity level. The documents are not on the data sheet, they are requested from the vendor, and a project that needs them should ask at the quotation stage rather than after the first build.

Nothing here isolates power. The barrier separates signals, and each side needs its own supply, which usually means a small isolated converter. A customer who expects a single rail to feed both sides will find that the part works but the isolation is defeated by the shared ground.

Where four channels with two each way land

An isolated UART needs two channels, one each way, so two of these parts cover two ports. An isolated SPI with a return data line is three forward and one back, which is the 6741. Motor drive signals, current sense interfaces and isolated ADC control lines are the other common uses, and they usually need a mixed split.

The 50 Mbps rate covers all of them with margin, and the wide body package with more than 8 mm of clearance is what a mains referenced barrier needs on a two layer board with a slot under the package.

What the order code decides

The string reads ISO674 for the family, 2 for the two forward and two reverse split, F for the default low state, DW for the wide body package and R for the reel of 2000.

The F is the character that most often gets dropped by accident, and it changes the behaviour on power loss without changing the pinout, the package or the price band. Any substitution inside this family should be checked against the safe state of every signal it carries.

Where this order code fits

Isolated UART and SPI links, gate drive signal paths, isolated current sense interfaces and any board where a 1.8 V controller has to talk to a 5 V field side across a certified barrier. Teams comparing it with a neighbouring part start from our Pin to Pin Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.

Questions buyers ask

What does the F mean? The default output state when the input side loses power or signal: low with the F, high without it. The pinout and the package do not change.

How much current does it draw? About 1.6 mA per channel at 1 Mbps, so roughly 6.4 mA per side for this four channel part at that rate.

Can both sides run at different voltages? Yes, each side accepts 1.71 V to 1.89 V or 2.25 V to 5.5 V independently, so a 1.8 V controller and a 5 V driver share one package.

Is the reel level 1? No, level 2 with a one year floor life. A reel that has been open a long time needs a bake before reflow.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Incoming Inspection Plan page sets out the checks that keep a substitute from failing on the bench.