ISO3088DWR
Product Specifications
ISO3088DWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO3088DWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO3088DWR: The 20 Mbps Half-Duplex Member of the ISO308x Isolated RS-485 Family
ISO3088DWR is an isolated half-duplex RS-485 and RS-422 transceiver in a SOIC body of 16 pins. It puts a 5 V bus-side driver and receiver behind a 2500 VRMS barrier, so a field bus that sits at a different ground potential from the controller can be read without a ground loop.
Order code and package
| Ordering string | ISO3088DWR |
| Package | SOIC, 16 pins, DW body |
| Body size | 10.30 mm by 7.50 mm, nominal |
| Carrier | Tape and reel, 330 mm reel, 16.4 mm tape, pocket 10.75 by 10.7 by 2.7 mm, pin 1 quadrant Q1 |
| Logic-side supply | 3.15 V minimum to 5.5 V maximum |
| Bus-side supply | 4.5 V minimum to 5.5 V maximum |
| Temperature range | minus 40 to plus 85 degrees Celsius |
| Duplex | Half duplex, one differential pair with DE and RE control |
| Family position | Fastest half-duplex member, the full-duplex equivalent is ISO3086 |
Electrical parameters that decide the application
| Signaling rate | 20 Mbps |
| Driver differential output, 54 ohm load | 1.5 V minimum, 2.3 V typical |
| Driver differential output, 100 ohm RS-422 load | 2 V minimum, 2.3 V typical |
| Driver common-mode output | 1 V minimum to 3 V maximum, steady-state shift within 100 mV |
| Receiver threshold | Plus threshold minus 85 to minus 10 mV, minus threshold minus 200 to minus 115 mV |
| Receiver hysteresis | 4 mV typical, 30 mV maximum |
| Bus loading | 1/8 unit load, up to 256 nodes on one bus |
| Bus input capacitance | 16 pF typical |
| Driver propagation delay | 25 ns typical, 45 ns maximum |
| Pulse width distortion | 3 ns typical, 9 ns maximum |
| Driver rise and fall time | 7 ns typical, 15 ns maximum |
| Common-mode transient immunity | 50 kV per microsecond, typical |
| ESD, bus pins to GND2 | plus or minus 12 kV human body model |
| ESD, bus pins to GND1 and all pins | plus or minus 6 kV and plus or minus 4 kV human body model, plus or minus 1 kV charged device model |
| Isolation rating | 2500 VRMS for 60 s per UL 1577, 4000 VPK basic insulation per DIN EN IEC 60747-17 |
| Working voltage | 560 VPK maximum repetitive peak isolation voltage |
| Clearance and creepage | 8 mm external, material group II, comparative tracking index above 400 V |
| Fail-safe | Receiver output high on bus open, short and idle |
Family variants and how they differ
| ISO3080 | Full duplex, 0.7 microsecond class delay, 16 pins |
| ISO3082 | Half duplex, 0.7 microsecond class delay, 16 pins |
| ISO3086 | Full duplex, 25 ns class delay, 16 pins |
| ISO3088 | Half duplex, 25 ns class delay, 16 pins, the part on this page |
| Delay split inside the family | The fast pair runs 25 ns typical and 45 ns maximum against 0.7 microsecond typical and 1.3 microsecond maximum on the slow pair |
| Distortion split inside the family | 3 ns typical on the fast pair against 20 ns typical and 200 ns maximum on the slow pair |
| Shared across all four | 5 V bus side, 2500 VRMS barrier, 1/8 unit load, 16 pF bus capacitance, fail-safe receiver, thermal shutdown |
| Later generation | ISO1430 and ISO1450 move to a 5000 VRMS barrier, a 1.71 V logic side and 12 Mbps and 50 Mbps rates |
Points to check before this part goes on a BOM
The bus side needs 4.5 V, the logic side does not.Two supplies are involved and only one of them is 5 V. The bus side runs from 4.5 V to 5.5 V because RS-485 levels are defined against a 5 V driver, while the logic side accepts 3.15 V to 5.5 V and the D, DE and RE inputs are 5 V tolerant, so a 3.3 V controller drives the part without a level translator.
The 256 node figure is a load figure, not a wiring allowance.One eighth of a unit load is what allows 256 receivers on one pair, but every node still adds capacitance and stub length. A 256 node bus with 1 m stubs is 256 m of copper, and the 20 Mbps rate will not survive that, so the node count and the data rate have to be traded against each other.
Half duplex means the driver has to let go.DE has to fall within one bit time of the last stop bit, or the driver holds the pair while another node starts talking. With a 45 ns maximum delay and a 50 ns bit at 20 Mbps, the firmware has to release the driver on the transmit-empty flag and not on a timer.
560 VPK is a working voltage, not a surge rating.The 4000 VPK transient and the 2500 VRMS one-minute figures are type tests. The number that governs a repeating waveform is the 560 VPK repetitive peak. A 400 V DC bus with inductive ringing that touches 600 V is outside the part, and the 5 kVRMS ISO14xx family is the correct move.
The temperature window is 85 degrees, not 125.This is the one number in the family that catches cabinet builders. A drive with the board mounted above a heatsink can sit at 90 degrees inside a 40 degree room, and the part is then outside its rated ambient while still working, which is the worst place to be.
The reel quantity is not on the row.The addendum prints the 330 mm reel and the 16.4 mm tape against ISO3088DWR but leaves the quantity column blank on that row while other rows in the same table carry 2000. Order by the full string and confirm the piece count on the reel label rather than assuming the sibling figure.
What the fail-safe receiver does on an idle bus
A terminated bus with no driver enabled sits at 0 V differential, which is inside the indeterminate window of a plain RS-485 receiver and produces random output. This part sets the output high when the differential falls below the negative threshold, so an idle bus reads as a mark and the UART sees a continuous logic high rather than noise.
That removes the external bias network on short buses. On a long bus with several terminations the bias current still has to come from somewhere, and the internal pull is weak enough that four 120 ohm terminations in parallel will hold the pair near zero, so the bias resistors stay in the circuit for multi-drop buses.
Why 16 pF of bus capacitance matters
Sixteen picofarads per node is roughly half what a standard transceiver presents, and it is the reason a 256 node bus can be discussed at all. At 20 Mbps the unit interval is 50 ns, and the rise time has to stay under about a fifth of that, which limits the total load a driver can charge.
The practical consequence is that the pin capacitance figure, not the node count, sets the cable length at the top rate. A bus that runs at 20 Mbps on 100 m will not run at 20 Mbps on 500 m even though the node count is unchanged.
Where this order code fits
Industrial drives, building automation controllers and metering concentrators use this part where the field pair is already 5 V RS-485 and the isolation is there to break a ground loop rather than to meet a 5 kV safety clause. Teams comparing it with a neighbouring part start from our CAN Bus Transceiver Selection page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.
Questions buyers ask
Can ISO3088DWR replace an eight-pin 75176 socket? No. It is a 16-pin wide-body part with two supplies and a barrier in the middle, so the footprint and the power tree both change. What carries over is the logic interface and the bus behaviour, not the pad geometry.
Does the bus side work at 3.3 V? Not within specification. The bus-side minimum is 4.5 V, so a 3.3 V bus supply is outside the recommended range even though the logic side is happy at 3.3 V. The ISO14xx family is the one with a 3 V bus-side floor.
Is external fail-safe biasing still needed? On a two-node bench bus, no. On a multi-drop bus with several terminations, yes, because the internal pull cannot hold a heavily terminated pair above the threshold when every driver is off.
What happens if the bus side loses power while the logic side stays alive? The receiver output goes to its fail-safe state and the bus pins go high impedance. The part does not present a load to the live side, which is the property that lets a hot-swapped module be pulled without dragging the bus down.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.