ISO3080DWR
Product Specifications
ISO3080DWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO3080DWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO3080DWR: Isolated Full-Duplex RS-485 Transceiver, 20 Mbps, 2500 V rms Barrier
ISO3080DWR is a full-duplex isolated RS-485 transceiver in a 16-pin SOIC body of 16 pins. The barrier is tested to 2500 V rms for 60 s under UL 1577, 4000 V peak of basic insulation under VDE 0884-17 and 4000 V peak under CSA 62368-1, and the bus pins present one eighth of a unit load, so 256 of these nodes can hang on one pair.
Order code and package
| Ordering string | ISO3080DWR, SOIC-16 (DW), 10.30 mm by 7.50 mm, tape and reel |
| Function | full duplex, one driver on Y and Z, one receiver on A and B, separate DE and RE |
| Supplies | VCC1 3.3 V or 5 V on the logic side, VCC2 5 V on the bus side, two rails and one barrier |
| Signalling rate | 20 Mbps maximum, both directions at once because the pair is separate |
| Bus loading | 1/8 unit load, 256 nodes, 16 pF typical differential input capacitance |
| Temperature | -40 C to +85 C ambient, 150 C junction, 150 C maximum safety temperature |
| Certifications | UL 1577 2500 V rms for 60 s, VDE 0884-17 4000 V peak basic, CSA 62368-1 4000 V peak |
Electrical parameters that decide the application
| Working isolation | VIORM 560 V peak repetitive, the number that governs service life |
| Transient immunity | 25 kV/us minimum, 50 kV/us typical, common mode |
| Driver output | 1.5 V minimum into 54 ohm, 2 V minimum into 100 ohm for RS-422 |
| Propagation delay | 95 ns typical, 225 ns maximum, driver and receiver |
| Bus input current | 0.1 mA typical at 12 V, 0.13 mA maximum with the bus side unpowered |
| Differential input resistance | 48 kohm measured at the A and B pins |
| Thermal resistance | 79.6 C/W junction to ambient in the DW package on a high-K board |
| Safety current | 286 mA at 5.5 V and 25 C, the current that reaches the 150 C junction |
| ESD | 12 kV HBM bus pins to GND2, 6 kV HBM bus pins to GND1, 4 kV all pins |
Points to check before this part goes on a BOM
2500 V rms for 60 s is a withstand test, not a working rating, and converting it shows the gap: 2500 V rms is 3535 V peak, 6.3 times the 560 V peak working voltage in the same table. A 400 V bus therefore uses 71 percent of the working limit, while an engineer reading only the 2500 V headline would think there was a factor of six left.
Each 1/8 unit load node draws 125 uA at 12 V, so 256 nodes draw 32 mA before any termination current, and the 54 ohm termination at the far end draws 27.8 mA at the 1.5 V minimum differential output. The two are the same order, which is why the 256 node figure only holds when the bias and termination resistors are counted together and the driver is not asked for a fourth node group.
The 225 ns maximum propagation delay is 4.5 bit periods at 20 Mbps, so a repeater chain adds latency in whole bit times and the turnaround of a half-duplex protocol is what limits cable length. The 20 Mbps figure also belongs to short runs: a 1200 m twisted pair carries roughly 100 kbps, so the rate is headroom for backplanes, not a promise about field cable.
Transient immunity is quoted as a slope, and 50 kV/us typical across a 560 V working voltage is an 11.2 ns edge. A switching inverter with a 1 us edge is 0.56 kV/us, ninety times below the limit, while a fast GaN stage next to the cable can reach the quoted figure, which is the case where the isolated part earns its price.
Power in the barrier is small but not zero: the logic side draws 10 mA at 5 V and the bus side 15 mA at 5 V, so 125 mW keeps the device at a 10 C rise on the 79.6 C/W figure, and the 286 mA safety current at 5.5 V allows 1.57 W at 25 C ambient before the junction reaches 150 C. The driver into a terminated pair is the larger term and it sits in the same thermal budget.
The temperature range stops at +85 C, so a cabinet at 90 C is outside the part whatever the isolation rating says, and the fail-safe receiver covers a bus that is open, shorted or idle, not one that is terminated and undriven by a dead node. A full-duplex device also needs its own four-wire cable, so the half-duplex ISO3082 is not a socket substitute.
Where this order code fits
These parts sit in factory automation, motor and motion control, HVAC networks, chemical plant instrumentation and networked security stations, where a cable run between cabinets breaks the ground loop and the common mode between the two ends is the reason for the barrier. Teams comparing it with a neighbouring part start from our Pin to Pin Cross Reference page, and teams replacing a part that has gone end of life start from the Component Obsolescence Management page.
Questions buyers ask
Is the second supply mandatory? Yes. The bus side needs 5 V at VCC2; only the logic side may be 3.3 V or 5 V, and the 3.3 V inputs remain 5 V tolerant when VCC1 is 5 V.
Can this part sit directly on a 2.5 kV bus? No. 2500 V rms is a one minute withstand, the repetitive working voltage is 560 V peak, and a 400 V bus already uses 71 percent of it.
What happens with the bus side unpowered? The bus input current falls to 0.13 mA maximum and the pins stay high impedance, which is why a node can be powered down without loading the pair.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.