Contact Us

ISO1430BDWR

Brand: Texas Instruments
Texas Instruments ISO1430BDWR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ISO1430BDWR — Power Management & Signal Chain | Superb Automation

ISO1430BDWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The ISO1430BDWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO1430BDWR: 12 Mbps Half-Duplex RS-485 Behind a 5000 VRMS Barrier

ISO1430BDWR is an isolated half-duplex RS-485 and RS-422 transceiver in a SOIC body of 16 pins. It sits in the ISO14xx family, which raises the barrier to 5000 VRMS, widens the logic supply down to 1.71 V and pushes the ambient range to 125 degrees, at a 12 Mbps signaling rate.

Order code and package

Ordering stringISO1430BDWR
PackageSOIC, 16 pins, DW body, 10.30 mm by 10.30 mm
CarrierTape and reel, 2000 pieces, 330 mm reel, 16.4 mm tape, pocket 10.75 by 10.7 by 2.7 mm, Q1
Box353 mm by 353 mm by 32 mm, one reel per box
Logic-side supply1.71 V to 5.5 V
Bus-side supply3 V to 5.5 V
Temperature rangeminus 40 to plus 125 degrees Celsius
DuplexHalf duplex
B suffixBasic isolation option inside the family

Electrical parameters that decide the application

Signaling rate12 Mbps
Bus I/O protectionPlus or minus 30 kV human body model, plus or minus 16 kV IEC 61000-4-2 contact, plus or minus 4 kV IEC 61000-4-4 fast transient
Isolation rating5000 VRMS for one minute per UL 1577
Transient isolation voltage7071 VPK per DIN EN IEC 60747-17
Working voltage1500 VPK maximum repetitive peak, reinforced and basic options both quoted at that figure
Common-mode transient immunity100 kV per microsecond typical
Bus loading1/8 unit load, up to 256 nodes
ReceiverFail-safe on bus open, short and idle
Logic-side currentQuoted per side in the supply current tables, side 1 and side 2 separate
Propagation delayQuoted per data rate option in the switching tables, 500 kbps and 12 Mbps and 50 Mbps members differ
Level translationAny logic side from 1.71 V to 5.5 V against any bus side from 3 V to 5.5 V
Power-up behaviourGlitch-free on power-up and power-down for hot plug-in
CertificationsVDE 0884-17, UL 1577, GB 4943.1, IEC 62368-1, IEC 60601-1, IEC 61010-1, CQC, TUV and CSA

Family variants and how they differ

ISO1410 and ISO1410BHalf duplex, 500 kbps
ISO1412 and ISO1412BFull duplex, 500 kbps
ISO1430 and ISO1430BHalf duplex, 12 Mbps, the part on this page
ISO1432 and ISO1432BFull duplex, 12 Mbps
ISO1450 and ISO1450BHalf duplex, 50 Mbps
ISO1452 and ISO1452BFull duplex, 50 Mbps
What the B suffix changesThe suffix denotes the basic isolation option, the plain string is the reinforced option, and both are printed at 1500 VPK working voltage in this revision
Pin compatibilityThe family is described as pin compatible with most isolated RS-485 transceivers, so a change of rate inside the family keeps the footprint

Points to check before this part goes on a BOM

Six members, two axes.The family splits by duplex and by rate, and the ordering string carries both. A board that needs full duplex at 500 kbps takes ISO1412B, not ISO1410B, and the pin functions differ between the two groups, so the duplex choice is a circuit decision rather than a BOM decision.

A 3 V bus-side floor changes who can use it.This part runs its bus side from 3 V, which means a 3.3 V rail can supply the isolated side directly instead of regulating 5 V behind the barrier. That saves a regulator and a winding on the isolated supply, and it is the main practical difference against the ISO308x generation.

The 1500 VPK working voltage is the number to read twice.7071 VPK is a transient figure for a 1.2 by 50 microsecond waveform. The continuous repetitive peak is 1500 VPK, and a 690 V AC drive bus with ringing can approach that. If the application works above 1000 V RMS continuously, the insulation lifetime tables in the document are the place to check, not the headline rating.

Logic-side range down to 1.71 V is a level translation statement.Side 1 accepts 1.71 V to 5.5 V and side 2 accepts 3 V to 5.5 V independently, so a 1.8 V FPGA can drive a 5 V bus without a translator between them. The two supplies do not have to match and neither has to be the higher one.

Glitch-free power sequencing matters on a hot-swap card.The part is specified to come up and go down without driving the bus, which is what allows a module to be inserted into a live rack. The condition is that both supplies ramp within the stated window; a bus side that comes up 200 ms after the logic side leaves the driver in an undefined state for that interval.

Bandwidth and cable length still bind.12 Mbps is 83 ns per bit. On 120 ohm cable with 16 pF nodes, that supports roughly 100 m before the eye closes, and the 256 node count is a DC load statement that says nothing about that limit.

What the 16 kV contact discharge rating removes from the board

The bus pins are rated for plus or minus 16 kV IEC 61000-4-2 contact and plus or minus 4 kV electrical fast transient without external parts, which is the reason this family is used on equipment that has to pass IEC 61000-4-2 level 3 or 4 at the connector.

The rating is a device-level number measured with the pin exposed. Once the connector, the cable shield and the enclosure are in the path, the system test still has to be run, and a series ferrite or a TVS at the connector may still be needed to keep the surge out of the board. What the part removes is the per-node protection network, not the system-level one.

Reading the two supply-current tables

The document gives supply current for side 1 and side 2 separately, at each data rate, with the driver enabled and disabled. That split matters because the isolated side usually comes from a small transformer whose winding is sized for the average current, not the peak.

A receiver-only node draws far less than a node that drives, so the isolated supply on a listen-only module can be sized from the receiver rows. Sizing it from the driver rows wastes winding and copper on a rail that never sees the current.

What a 5000 VRMS barrier does not cover

The barrier rating describes the insulation between pin group 1 and pin group 2. It says nothing about the supply that feeds side 2, and an isolated transceiver with a common ground on both sides has no isolation at all regardless of the certificate. The isolated supply, the connector pinout and the board clearance are all part of the same argument and none of them is carried by the part.

The second thing the rating does not cover is the transient on the cable. A 16 kV contact discharge is a device-level test on the pins, and a lightning surge arriving on a 200 m field cable will be far larger by the time it reaches the board unless the cable entry is protected. The part earns its place by removing the per-node network, and the entry protection stays where the standard puts it.

Where this order code fits

Process instrumentation, motor drives and substation equipment use this part where the field bus sits on a 5 kV barrier and the ambient inside the enclosure reaches 100 degrees or more. Teams comparing it with a neighbouring part start from our CAN Bus Transceiver Selection page, and teams replacing a part that has gone end of life start from the Obsolete Part Cross Reference Hub page.

Questions buyers ask

Is ISO1430B the same footprint as ISO3088? Both are 16-pin wide-body SOIC, and the family is described as pin compatible with most isolated RS-485 transceivers. The supply ranges differ, so the change is a power tree check rather than a pad change.

Does the B suffix mean a lower isolation rating? It denotes the basic insulation option against the reinforced option. Both are printed with the same 1500 VPK working voltage in this revision, and the difference sits in the type test and the certification clause the equipment has to meet.

Can the logic side run at 1.8 V? Yes, side 1 accepts 1.71 V to 5.5 V, and side 2 is independent at 3 V to 5.5 V. The two rails do not need to be equal.

What replaces it if 12 Mbps is not enough? ISO1450B is the 50 Mbps half-duplex member with the same barrier and the same supply ranges, so the footprint carries over and only the timing budget changes.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.