ISO1430BDWR
Product Specifications
ISO1430BDWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO1430BDWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO1430BDWR: 12 Mbps Half-Duplex RS-485 Behind a 5000 VRMS Barrier
ISO1430BDWR is an isolated half-duplex RS-485 and RS-422 transceiver in a SOIC body of 16 pins. It sits in the ISO14xx family, which raises the barrier to 5000 VRMS, widens the logic supply down to 1.71 V and pushes the ambient range to 125 degrees, at a 12 Mbps signaling rate.
Order code and package
| Ordering string | ISO1430BDWR |
| Package | SOIC, 16 pins, DW body, 10.30 mm by 10.30 mm |
| Carrier | Tape and reel, 2000 pieces, 330 mm reel, 16.4 mm tape, pocket 10.75 by 10.7 by 2.7 mm, Q1 |
| Box | 353 mm by 353 mm by 32 mm, one reel per box |
| Logic-side supply | 1.71 V to 5.5 V |
| Bus-side supply | 3 V to 5.5 V |
| Temperature range | minus 40 to plus 125 degrees Celsius |
| Duplex | Half duplex |
| B suffix | Basic isolation option inside the family |
Electrical parameters that decide the application
| Signaling rate | 12 Mbps |
| Bus I/O protection | Plus or minus 30 kV human body model, plus or minus 16 kV IEC 61000-4-2 contact, plus or minus 4 kV IEC 61000-4-4 fast transient |
| Isolation rating | 5000 VRMS for one minute per UL 1577 |
| Transient isolation voltage | 7071 VPK per DIN EN IEC 60747-17 |
| Working voltage | 1500 VPK maximum repetitive peak, reinforced and basic options both quoted at that figure |
| Common-mode transient immunity | 100 kV per microsecond typical |
| Bus loading | 1/8 unit load, up to 256 nodes |
| Receiver | Fail-safe on bus open, short and idle |
| Logic-side current | Quoted per side in the supply current tables, side 1 and side 2 separate |
| Propagation delay | Quoted per data rate option in the switching tables, 500 kbps and 12 Mbps and 50 Mbps members differ |
| Level translation | Any logic side from 1.71 V to 5.5 V against any bus side from 3 V to 5.5 V |
| Power-up behaviour | Glitch-free on power-up and power-down for hot plug-in |
| Certifications | VDE 0884-17, UL 1577, GB 4943.1, IEC 62368-1, IEC 60601-1, IEC 61010-1, CQC, TUV and CSA |
Family variants and how they differ
| ISO1410 and ISO1410B | Half duplex, 500 kbps |
| ISO1412 and ISO1412B | Full duplex, 500 kbps |
| ISO1430 and ISO1430B | Half duplex, 12 Mbps, the part on this page |
| ISO1432 and ISO1432B | Full duplex, 12 Mbps |
| ISO1450 and ISO1450B | Half duplex, 50 Mbps |
| ISO1452 and ISO1452B | Full duplex, 50 Mbps |
| What the B suffix changes | The suffix denotes the basic isolation option, the plain string is the reinforced option, and both are printed at 1500 VPK working voltage in this revision |
| Pin compatibility | The family is described as pin compatible with most isolated RS-485 transceivers, so a change of rate inside the family keeps the footprint |
Points to check before this part goes on a BOM
Six members, two axes.The family splits by duplex and by rate, and the ordering string carries both. A board that needs full duplex at 500 kbps takes ISO1412B, not ISO1410B, and the pin functions differ between the two groups, so the duplex choice is a circuit decision rather than a BOM decision.
A 3 V bus-side floor changes who can use it.This part runs its bus side from 3 V, which means a 3.3 V rail can supply the isolated side directly instead of regulating 5 V behind the barrier. That saves a regulator and a winding on the isolated supply, and it is the main practical difference against the ISO308x generation.
The 1500 VPK working voltage is the number to read twice.7071 VPK is a transient figure for a 1.2 by 50 microsecond waveform. The continuous repetitive peak is 1500 VPK, and a 690 V AC drive bus with ringing can approach that. If the application works above 1000 V RMS continuously, the insulation lifetime tables in the document are the place to check, not the headline rating.
Logic-side range down to 1.71 V is a level translation statement.Side 1 accepts 1.71 V to 5.5 V and side 2 accepts 3 V to 5.5 V independently, so a 1.8 V FPGA can drive a 5 V bus without a translator between them. The two supplies do not have to match and neither has to be the higher one.
Glitch-free power sequencing matters on a hot-swap card.The part is specified to come up and go down without driving the bus, which is what allows a module to be inserted into a live rack. The condition is that both supplies ramp within the stated window; a bus side that comes up 200 ms after the logic side leaves the driver in an undefined state for that interval.
Bandwidth and cable length still bind.12 Mbps is 83 ns per bit. On 120 ohm cable with 16 pF nodes, that supports roughly 100 m before the eye closes, and the 256 node count is a DC load statement that says nothing about that limit.
What the 16 kV contact discharge rating removes from the board
The bus pins are rated for plus or minus 16 kV IEC 61000-4-2 contact and plus or minus 4 kV electrical fast transient without external parts, which is the reason this family is used on equipment that has to pass IEC 61000-4-2 level 3 or 4 at the connector.
The rating is a device-level number measured with the pin exposed. Once the connector, the cable shield and the enclosure are in the path, the system test still has to be run, and a series ferrite or a TVS at the connector may still be needed to keep the surge out of the board. What the part removes is the per-node protection network, not the system-level one.
Reading the two supply-current tables
The document gives supply current for side 1 and side 2 separately, at each data rate, with the driver enabled and disabled. That split matters because the isolated side usually comes from a small transformer whose winding is sized for the average current, not the peak.
A receiver-only node draws far less than a node that drives, so the isolated supply on a listen-only module can be sized from the receiver rows. Sizing it from the driver rows wastes winding and copper on a rail that never sees the current.
What a 5000 VRMS barrier does not cover
The barrier rating describes the insulation between pin group 1 and pin group 2. It says nothing about the supply that feeds side 2, and an isolated transceiver with a common ground on both sides has no isolation at all regardless of the certificate. The isolated supply, the connector pinout and the board clearance are all part of the same argument and none of them is carried by the part.
The second thing the rating does not cover is the transient on the cable. A 16 kV contact discharge is a device-level test on the pins, and a lightning surge arriving on a 200 m field cable will be far larger by the time it reaches the board unless the cable entry is protected. The part earns its place by removing the per-node network, and the entry protection stays where the standard puts it.
Where this order code fits
Process instrumentation, motor drives and substation equipment use this part where the field bus sits on a 5 kV barrier and the ambient inside the enclosure reaches 100 degrees or more. Teams comparing it with a neighbouring part start from our CAN Bus Transceiver Selection page, and teams replacing a part that has gone end of life start from the Obsolete Part Cross Reference Hub page.
Questions buyers ask
Is ISO1430B the same footprint as ISO3088? Both are 16-pin wide-body SOIC, and the family is described as pin compatible with most isolated RS-485 transceivers. The supply ranges differ, so the change is a power tree check rather than a pad change.
Does the B suffix mean a lower isolation rating? It denotes the basic insulation option against the reinforced option. Both are printed with the same 1500 VPK working voltage in this revision, and the difference sits in the type test and the certification clause the equipment has to meet.
Can the logic side run at 1.8 V? Yes, side 1 accepts 1.71 V to 5.5 V, and side 2 is independent at 3 V to 5.5 V. The two rails do not need to be equal.
What replaces it if 12 Mbps is not enough? ISO1450B is the 50 Mbps half-duplex member with the same barrier and the same supply ranges, so the footprint carries over and only the timing budget changes.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.