ISO1044BDR
Product Specifications
ISO1044BDR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO1044BDR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO1044BDR: isolated CAN FD transceiver in an eight pin package
ISO1044BDR is an isolated CAN FD transceiver in a small outline package in a SOIC body of 8 pins. It is the compact member of the isolated CAN family, with a 3000 V RMS barrier, 5 Mbps of flexible data rate throughput and 58 V of bus fault protection in an eight pin body. The BDR order code is the eight pin SOIC on a reel.
Order code and package
| Order code | ISO1044BDR |
| Package | 8-pin SOIC, D |
| Packing | tape and reel |
| Data rate | 1 Mbps classic CAN, 5 Mbps CAN FD |
| Isolation | 3000 V RMS withstand, 450 V RMS working, 637 V peak repetitive |
| Bus fault protection | 58 V DC on the bus pins |
| Common mode | plus or minus 12 V |
| Supply | VCC1 1.71 V to 5.5 V, VCC2 4.5 V to 5.5 V |
Electrical parameters that decide the application
| Bus ESD | 10 kV human body model, 8 kV IEC contact on the bus pins |
| Supply current side 1 | 2.4 mA typical, 3.5 mA maximum at 5 V |
| Isolation barrier | silicon dioxide |
| Temperature range | minus 40 to plus 125 degrees |
| Package width | narrow body, 3.9 mm |
| Pin count | 8, with the barrier pins on both sides |
Family variants and how they differ
| ISO1044B | 8-pin, 3000 V RMS, 58 V bus fault, this order code |
| ISO1042DW | 16-pin, 5000 V RMS, 70 V bus fault |
| ISO1042DWV | 8-pin, 5000 V RMS, 70 V bus fault |
| ISO1044BDR | tape and reel packing |
Points to check before this part goes on a BOM
The eight pin body is the reason to choose this part, and the trade is a 3000 V RMS barrier against the 5000 V RMS of the sixteen pin version, with a 450 V RMS working voltage against 1060 V RMS. A 400 V system is close to the working limit and a 48 V system is far below it, so the choice follows the bus voltage and not the pin count.
Common mode range is plus or minus 12 V here against plus or minus 30 V on the larger part. On a short harness inside one enclosure that difference never shows, but on a vehicle harness with separate grounds it is the specification that decides whether the network survives.
Bus fault protection of 58 V is lower than the 70 V of the ISO1042 for the same reason: less silicon. A 48 V battery system with load dump transients above 58 V needs a clamp on the bus pins, and the clamp belongs on the connector side of the barrier rather than behind it.
Side two still requires 4.5 V to 5.5 V, so the isolated rail is a 5 V rail. Side one runs from 1.71 V, which allows a 1.8 V controller without a level translator, and this is the usual reason a product picks the part over a 3.3 V only transceiver.
The measured supply current of 2.4 mA typical and 3.5 mA maximum on side one is what the isolated supply has to deliver in addition to side two. A small transformer driver and a rectifier sized from the transceiver current alone usually comes up short once the driver switching losses are counted.
There is no separate isolated enable output on this package. Direction control for a half duplex arrangement has to come from the controller side, and the barrier carries the TXD and RXD signals only, which is the compromise the eight pin body makes against the sixteen pin family.
An eight pin isolated package has less creepage than a wide body sixteen pin part, and the footprint has to preserve what it does have. A board that routes a signal trace under the body or places a via in the barrier region reduces the effective distance, and the 3000 V RMS rating then belongs to the package rather than to the assembly.
At 5 Mbps a bit is 200 ns and the loop delay of the part is a large fraction of it, so the usable bus length in the data phase is set by the delay plus the cable. A 40 m segment that works at 500 kbps will not carry 2 Mbps, and the arbitration phase stays at the classic rate while only the data phase is fast.
A CAN node that loses its isolated supply behaves differently from one that loses its logic supply, and the two states are worth separating in a fault log. With side two absent the bus pins are passive and the node is invisible; with side one absent the node can still drive the bus if the controller is holding the transmit line low through a pull down, which is how a single faulty module silences an otherwise healthy segment. Both states should be distinguishable in the module status register before the harness is opened. Both states should be distinguishable in a module status register before the harness is opened, because a node with no isolated rail and a node with no logic rail produce the same silent bus.
Where this order code fits
It is used where board area is tight inside an isolated CAN node: battery management slaves, motor inverter interfaces, compact industrial gateways and sensor modules on a 48 V rail. Teams comparing it with a neighbouring part start from our CAN Bus Transceiver Selection page, and teams replacing a part that has gone end of life start from the How to Verify a Drop in Replacement page.
Questions buyers ask
Can it replace an ISO1042 on the same footprint? No. The ISO1042 in the sixteen pin body has a different pinout and a wider barrier, so the footprint and the isolation budget both change.
What is the maximum bus voltage it survives? 58 V DC on the bus pins, which covers a 48 V system but not the transients above it without an external clamp.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.