INA260AIPWR

Brand: Texas Instruments
Texas Instruments INA260AIPWR is a power management component designed for Industrial Automation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

INA260AIPWR — Power Management & Signal Chain | Superb Automation

INA260AIPWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The INA260AIPWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

INA260AIPWR: the 15 amp monitor with the shunt inside, on a 2000 piece reel

INA260AIPWR is the I2C current, voltage and power monitor with a 2 milliohm shunt inside the 16 pin TSSOP, on a 2000 piece large reel. It measures 0 to 36 volts of bus and up to 15 amps continuous from minus 40 to plus 85 degrees, with a 16 bit converter, a current least significant bit of 1.25 milliamps and a power register that does the multiplication in the part.

The integration removes the Kelvin connection from the board: the shunt and its sense pair are inside the package, so the measurement does not depend on how well the copper was laid out around an external resistor. The cost is the ceiling, 36 volts of bus and 15 amps, and the dissipation at the top of the range, 0.45 watts inside a 5.00 by 4.40 millimetre body.

INA260AIPWR as the vendor document publishes it

Integrated shunt2 milliohms, tolerance equivalent to 0.1 per cent
Shunt temperature coefficient10 ppm per degree from 0 to 125 degrees
Continuous current15 amps from minus 40 to plus 85 degrees
Bus voltage range0 volts to 36 volts, independent of the supply
Supply range2.7 volts to 5.5 volts
Supply current310 microamps typical
ADC resolution16 bits
Current least significant bit1.25 milliamps
Bus least significant bit1.25 millivolts
Power least significant bit10 milliwatts
System current gain error0.02 per cent typical, 0.15 per cent maximum at 25 degrees
Current sense offset1.25 milliamps typical, 5 milliamps maximum
Bus offset voltage0.6 millivolts typical, 1.5 millivolts maximum
Bus gain error0.02 per cent typical, 0.1 per cent maximum at 25 degrees
Common mode rejection150 dB
Conversion time140 microseconds to 8.244 milliseconds, eight settings
Averagingup to 1024 samples in the background
Addresses16, from 0x40 to 0x4F, set by two pins
Alert outputopen drain, programmable threshold and latch
Dissipation at 15 amps0.45 watts in the shunt inside the package
BodyTSSOP, 16 pin, PW, 5.00 by 4.40 millimetres
Temperature rangeminus 40 to plus 125 degrees
Vendor statusactive, 2000 piece large reel
Catalogue codeINA260AIPWR
Vendor stringINA260AIPWR
BodyTSSOP, PW, sixteen pin, 5.00 by 4.40 millimetres
MarkingI260AI
Moisture levellevel 2, 260 degrees, one year floor life

A two milliohm shunt inside the package

INA260AIPWR is a current and power monitor with the shunt already inside the 16 pin TSSOP: 2 milliohms, a tolerance equivalent to 0.1 per cent, and a temperature coefficient of 10 ppm per degree from 0 to 125 degrees. The point of the integration is not the bill of materials, it is the connection: a Kelvin pair to an external shunt is where a milliohm of trace and a via of solder resistance enter the measurement, and inside the package that pair is fixed.

The shunt also sets the ceiling. Fifteen amps continuous from minus 40 to plus 85 degrees is the rating, and at 15 amps the 2 milliohm element dissipates 0.45 watts inside a 5.00 by 4.40 millimetre body, which is why the top of the current range is a thermal number rather than an electrical one. A 20 amp channel does not get there by ignoring the rating; it needs a part with an external shunt and the Kelvin connection done properly on the board.

Sixteen bits, and the least significant bit that matters

The converter inside INA260AIPWR reports 16 bits with a current least significant bit of 1.25 milliamps, a bus least significant bit of 1.25 millivolts and a power least significant bit of 10 milliwatts, and the multiplication to watts happens in the part rather than in the host. The system current gain error is 0.02 per cent typical and 0.15 per cent maximum at 25 degrees, and the current sense offset is 1.25 milliamps typical and 5 milliamps maximum.

Read together, the two rows say where the part stops being useful. Five milliamps of offset against a 1.25 milliamp least significant bit is four codes, so a 100 milliamp standby current is measured with 5 per cent of error before the gain term is counted, and a 20 milliamp sleep current is mostly offset. The part is a power monitor for a working rail, not a microamp meter: for the sleep current the answer is a larger shunt with an amplifier, or a monitor whose offset is specified in microvolts rather than in milliamps.

Zero to thirty six volts of bus, independent of the supply

The bus input of INA260AIPWR measures 0 to 36 volts while the part runs from 2.7 to 5.5 volts, so a 24 volt rail is read directly from a 3.3 volt logic supply with no divider and no second reference. The measurement is bidirectional and works on the high side or the low side, so a charger that sources and sinks current reports both directions with the same sign convention.

The 36 volt ceiling is the number to read before the part is chosen. A 48 volt telecom bus, a 72 volt battery pack and a 400 volt traction bus are all outside it, and a divider in front of the bus pin fixes the voltage while adding a ratio error that has to be calibrated out. The current path is unaffected by the bus limit, because the shunt sits in the current path and the bus pin is a separate high impedance input, but a channel that needs both a 48 volt bus reading and a 15 amp current reading in one part needs a different family.

One hundred and forty microseconds to eight milliseconds of conversion

INA260AIPWR offers eight conversion time settings from 140 microseconds to 8.244 milliseconds, and an averaging engine that runs up to 1024 samples in the background without adding to the conversion time. A channel that has to be read every 5 milliseconds is set to 588 microseconds on both current and bus, with averaging on, and updates about every 4.7 milliseconds.

The choice is a noise decision. The shortest setting gives the fastest protection response and the noisiest reading, and the longest with the heaviest averaging gives a clean number that is nearly 10 milliseconds old. A protection loop wants the short setting and a logging channel wants the long one, and a single part can serve both only by alternating the configuration between a fast read and a slow read. The alert output is independent of the read rate: it compares against a programmed threshold on every conversion, so a host that polls slowly still gets the overcurrent flag.

Where an integrated shunt monitor fits, and where it does not

INA260AIPWR fits a server or a computing node that meters its own rails, a test instrument that logs current and power per channel, a telecom rectifier that reports output power, a battery charger that needs both directions, and a power supply that has to flag an overcurrent without an external comparator chain. In all of those the shunt is small, the current is under 15 amps and the bus is under 36 volts.

It does not fit a 48 volt bus, a current above 15 amps, or a channel that has to resolve milliamps at the bottom of a 15 amp range. It also does not fit a board that needs the measurement isolated from the logic ground, since the shunt and the logic share a die. Our converter cross reference page covers the external converter route for the cases where the bus is higher than the part allows, and the amplifier cross reference page covers the analogue path where a digital output is not wanted.

Sixteen addresses, one alert line and a bus that is already there

INA260AIPWR answers on I2C and SMBus at one of sixteen addresses from 0x40 to 0x4F set by two pins, which is enough for a shelf of eight line cards with two monitors each, or for a board that measures several rails with no multiplexer. The alert pin is open drain and programmable for threshold and latch, so an overcurrent event is caught by an interrupt rather than by a poll.

The interface is the reason the part exists in a server or a telecom shelf. There is no converter, no reference and no scaling network between the shunt and the host, and the host reads amperes and watts rather than a raw code and a calibration constant. The register set is small enough that a driver is a page of code, and the 310 microamp supply current is low enough that the monitor can stay on a standby rail. What the interface costs is latency: an I2C read of the power register at 400 kHz is tens of microseconds, and a control loop that closes through the bus runs at the bus rate rather than at the conversion rate.

A monitor with the shunt inside is a board level decision as much as a part number. Our converter cross reference page covers the external converter route where the bus is higher, and the BOM scrubbing page covers the substitution check against the bill of materials.

Can this part measure a 48 volt bus? No. The bus input is rated 0 to 36 volts; a divider in front of the bus pin adds a ratio error that has to be calibrated.

What is the smallest current it can resolve? The least significant bit is 1.25 milliamps but the maximum offset is 5 milliamps, so below 20 milliamps the offset is a quarter of the reading.