INA230AIRGTR
Product Specifications
INA230AIRGTR
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA230AIRGTR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA230AIRGTR: 36 V, 16 bit current, voltage and power monitor with an I2C interface in the sixteen pin VQFN
INA230AIRGTR is a digital power monitor that multiplies a shunt drop by a bus voltage inside the part and reports current in amperes, voltage in volts and power in watts over I2C in a VQFN body of 16 pins. It measures a shunt drop of up to plus or minus 81.92 mV on a bus that runs from 0 V to 36 V, converts both quantities with a 16 bit converter, and applies a calibration value the host writes once so the current register reads in engineering units. Sixteen addresses are available from two pins, and an alert output can be set for over current, over voltage or over power without host polling.
Order code and package
| INA230AIRGTR | VQFN RGT body, 16 pins, 3000 pieces on a large reel, Active, RoHS Yes, SN finish, moisture level 1 with unlimited floor life, part marking I230, minus 40 to plus 125 degrees |
| INA230AIRGTRG4 | the same RGT reel with a NIPDAU finish instead of SN, moisture level 1, marking I230 |
| INA230AIRGTRG4.A | printed as Obsolete in the same addendum, so this string should not appear on a new order |
| INA230AIDGSR | VSSOP DGS body, 10 pins, 2500 pieces on a large reel at moisture level 2 with a one year floor life, marking 2K5Q |
| INA230AIDGST | the same DGS body on a 250 piece small reel, the prototype route for the smaller package |
Electrical parameters that decide the application
| Bus voltage range | 0 V to 36 V on the bus pin, independent of the 2.7 V to 5.5 V supply |
| Shunt input range | plus or minus 81.92 mV full scale, with a 10 uV fixed shunt LSB across the 16 bit result |
| Shunt offset | 25 uV maximum over minus 40 to plus 125 degrees, 0.1 uV per degree of drift |
| Gain error | 0.3 per cent maximum on the current path, with the bus voltage path carrying its own gain error row |
| Common mode rejection | 120 dB minimum from 0 V to 36 V across the temperature range |
| Resolution | 16 bit on both channels, with the bus register using a fixed 1.25 mV per bit so a full scale register reads 40.96 V |
| Conversion time | 140 us, 204 us, 332 us, 588 us, 1.100 ms, 2.116 ms, 4.156 ms and 8.244 ms selected per channel in the configuration register |
| Averaging | an accumulator rolls the selected number of conversions into the output registers, and the conversion ready flag rises only after the averaging and the multiplication are complete |
| Addressing | 16 addresses from the A0 and A1 pins, each tied to ground, SCL, SDA or the supply, which is how a multi rail board is built without a bus switch |
| Alert output | programmable threshold and a conversion ready function, so an over current event is flagged from the device rather than from a host loop |
| Supply | 2.7 V to 5.5 V, 330 uA typical while converting, with a shutdown mode below that |
| Bus input impedance | 365 kOhm typical in current measurement mode, which is the load the bus sees on the monitored rail |
Family variants and how they differ
| RGT against DGS | the sixteen pin VQFN carries moisture level 1 unlimited and the ten pin VSSOP carries level 2 with a one year floor life, and the two bodies have their own input bias current rows in the electrical table |
| Two register scales | the current register is scaled by the calibration value the host writes, while the bus register is fixed at 1.25 mV per bit and the power register is fixed at 25 times the current LSB, so the host only chooses one scale and the other two follow |
| INA230 against INA226 | the same register map and the same 36 V bus, with the INA226 adding an alert pin arrangement and a different shunt full scale on some rows, so a board that already speaks one register map can usually be moved between them |
| INA230 against INA228 | the INA228 is the 85 V, 20 bit part with energy and charge accumulation, which is the step up when the 16 bit resolution or the 36 V bus ceiling is the limit |
Points to check before this part goes on a BOM
The calibration register is what turns raw counts into amperes. The current LSB is chosen as the maximum expected current divided by 32768, and the calibration value is then 0.00512 divided by the product of that LSB and the shunt resistance. A 15 A board gives 457.7 uA per bit, and rounding to 1 mA per bit is what most boards do because it makes the arithmetic legible at the cost of one bit of resolution.
The bus register is not scaled by the calibration value. Its least significant bit is fixed at 1.25 mV, so a 36 V rail reads 28800 counts and a 12 V rail reads 9600, and the 40.96 V full scale means the register does not saturate before the part's own 36 V rating. That is the reason the board does not have to compute a bus scale at all.
The power register is fixed at 25 times the current LSB. With a 1 mA per bit current scale the power LSB is 25 mW per bit, and the multiplication happens in hardware, so a host that reads power twice a second is not doing any arithmetic and cannot introduce a rounding error of its own.
Conversion time and averaging are two separate controls and they multiply. Eight conversion times from 140 us to 8.244 ms, times the averaging count, sets the update rate, and the two channels can carry different conversion times, so a fast over current channel and a quiet bus voltage channel can share one device. The alert path does not wait for the averaged result.
The two bodies do not share every electrical row. Input bias current and the bus input impedance are printed separately for the DGS and RGT parts, so a high impedance divider on the bus should be checked against the row for the body actually on the board rather than the headline figure.
The 3000 piece reel at moisture level 1 is the practical reason this body is popular: it can sit on a line without a dry pack schedule, while the ten pin VSSOP at level 2 needs one. That is a handling decision, not an electrical one, and it is the kind of difference that only shows up when a line is audited.
Setting the alert before the host is running
The alert output works from a threshold register, so the trip point exists from the moment the device is configured, which is before the host firmware has finished booting. On a battery pack or a power over ethernet port that is the difference between a fault being caught and a fault being reported after the damage, and the 140 us conversion time is the shortest window the trip can see.
What the 0.3 per cent gain error means in amperes
At a 15 A full scale the 0.3 per cent gain limit is 45 mA, and the 25 uV offset on a 2 milliohm shunt is 12.5 mA. The two are comparable, which is why a board that needs better than 5 per cent at a tenth of full scale has to look at the offset term first and the gain term second. The offset does not scale with current and dominates at the bottom of the range.
Where this order code fits
Rack servers, wireless infrastructure, high performance computing nodes, battery cell monitors, power supplies and test equipment are the applications the vendor names, and all of them want a rail that reports its own consumption instead of a shunt amplifier feeding a host converter. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Amplifier Cross Reference page.
Questions buyers ask
Can the INA230 measure a negative current? Yes. The shunt input is bipolar across plus or minus 81.92 mV, so a pack that charges and discharges through one resistor reports both directions.
Does it measure energy? No. It reports current, bus voltage and power. Energy and charge accumulation are in the INA228.
How many devices fit on one bus? Sixteen, from the A0 and A1 pins tied to ground, SCL, SDA or the supply.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.