INA214AIDCKR
Product Specifications
INA214AIDCKR
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA214AIDCKR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA214AIDCKR: the 100 V/V current shunt monitor in SC70
INA214AIDCKR is the 100 V/V gain member of the INA21x family, a voltage output current shunt monitor in a six pin SC70 body on a 3000 piece reel. The device measures the drop across a shunt resistor at a common mode voltage from minus 0.3 V to 26 V, independent of its own supply, and it does that with a zero drift amplifier chain whose offset is measured in tens of microvolts.
SBOS437K, revised November 2023, covers six gain options in one document: 50, 75, 100, 200, 500 and 1000 V/V. The INA214 is the 100 V/V member, which means a 10 millivolt shunt drop becomes 1 V at the output, and a 100 millivolt drop becomes 10 V, so the choice of shunt and the choice of gain are one decision rather than two.
What follows is what the gain means for a real measurement, the rows that decide accuracy at low shunt drops, the difference between the three accuracy grades, and the lifecycle detail on this specific code.
What 100 V/V does to a measurement
The gain network is integrated and trimmed, so the ratio is set by the die and not by external resistors. A 2 milliohm shunt carrying 5 A drops 10 millivolts, which becomes 1 V at the output, and a 12 bit converter with a 4.096 V reference resolves 1 millivolt per count, so the measurement resolves about 5 milliamps. That is the arithmetic a buyer should run before choosing the gain: the gain multiplies the shunt drop, and the converter divides it again.
| Orderable code | INA214AIDCKR |
| Gain | 100 V/V |
| Body | SC70, 6 pins, 2.00 mm by 1.25 mm |
| Carrier | 3000 pieces on a large reel |
| Common mode range | minus 0.3 V to 26 V |
| Supply voltage | 2.7 V to 26 V, single supply |
| Supply current | 100 microamps maximum |
| Common mode rejection | 105 dB minimum, 140 dB typical over the window |
| Gain error, A and B versions | plus or minus 1 percent maximum over temperature |
| Gain error, C version | plus or minus 0.5 percent maximum over temperature |
| Offset drift | 0.5 microvolts per degree maximum |
| Gain drift | 10 parts per million per degree maximum |
| Input bias current | 15 microamps typical, 28 maximum on the family table |
| Operating temperature | minus 40 to 125 degrees |
| Part marking | CFV |
| Moisture rating | level 2, 260 degrees for one year floor life |
Accuracy at a small shunt drop
The zero drift chopper front end is what makes a 10 millivolt full scale measurement practical. Offset drift of 0.5 microvolts per degree over a 100 degree swing is 50 microvolts, which on a 10 millivolt full scale is half a percent, and that sits beside a gain error of one percent rather than dominating it. A conventional amplifier with 5 microvolts per degree of drift would contribute 500 microvolts and swamp the measurement.
Common mode rejection of 105 dB minimum matters because the shunt usually sits on a rail that moves. A 12 V rail that swings by 2 V during a load step, with 105 dB of rejection, appears as 11 microvolts at the input, which is 1.1 millivolts at the output and about 0.1 percent of a 1 V full scale reading. That is the arithmetic behind the rejection figure and the reason it is printed as a minimum and not as a typical.
Input bias current of 15 microamps typical flows in the two input pins, and the two currents do not match exactly. A 10 milliohm shunt with 15 microamps of bias current develops 0.15 microvolts, which is negligible, but a 1 ohm shunt develops 15 microvolts, which is a third of the offset window. Shunts above about 100 milliohms are where bias current becomes the limiting error and where the gain should be raised instead of the shunt, and a 1 ohm shunt on a 20 millivolt drop is not a measurement circuit that any calibration can rescue.
Three accuracy grades in one table
The suffix letters are accuracy grades and they are printed in the same electrical table, which is why they get confused. The A and B versions carry a gain error of plus or minus 1 percent over temperature, the C version plus or minus 0.5 percent, and all of them share the same offset drift and gain drift rows. A buyer comparing prices across the grades should look at the gain error row first, because that is the whole difference.
The package is the second variable and it is the one that decides whether an existing board can take a new grade at all. The family is offered in a six pin SC70 at 2 mm by 1.25 mm and a ten pin thin UQFN at 1.8 mm by 1.4 mm, and the two do not share a footprint. On this code the addendum prints the ten pin UQFN row as obsolete and the six pin SC70 rows as active, which is the detail that matters when a board was released against the UQFN body years ago.
Where a high side monitor belongs
The part is used in three places: over current protection, where the output drives a comparator and the threshold is set by the shunt and the gain; precision measurement, where the output goes into a converter and the gain is chosen so the full scale matches the converter range; and closed loop feedback, where the current signal closes a loop around a motor or a charger. The three want different things from the same part, which is why the six gain options exist.
For over current protection the speed matters and the family bandwidth falls as the gain rises, so a 50 V/V part responds faster than a 1000 V/V part. For measurement the offset and the drift matter more than the speed. For a control loop the phase margin at the crossing frequency is decided by the amplifier bandwidth and by the output filter, so a 100 V/V part with a 1 kHz loop is comfortable and a 1000 V/V part in the same loop is not.
Bidirectional sensing is built in: the reference pin sets the zero current level, so a supply of 3.3 V with the reference held at 1.65 V gives a signal that swings either side of the midpoint and covers current in both directions. That is the configuration used on battery chargers, where the same shunt carries charge and discharge current. The amplifier cross reference page lists the gain options and their second sources, and the pin to pin cross reference page covers the check we run before a different gain is substituted on an existing board.
Questions that come with this code
Is the C grade worth the price difference? On a 1 percent measurement the difference between 1 percent and 0.5 percent gain error is the difference between a 12 bit result and an 11 bit result, so it matters where the measurement is the product and not where it is a protection threshold.
Can the device measure a negative rail? The common mode range starts at minus 0.3 V, so a small negative excursion is inside the window and a full negative rail is not. For a negative supply the part has to be referenced to that rail rather than to ground.
What happens if the shunt opens? The inputs see the full rail through the open shunt path, and the absolute maximum on the input pins is the supply plus 0.3 V, so a shunt that fails open can destroy the amplifier. A pair of series resistors at the input pins is the usual protection and it costs two components.
Why is the UQFN row printed obsolete while the SC70 row is active? The die is the same and the body changed. A board that was released on the UQFN body needs either a stock position or a board change, and there is no pin compatible path between the two. The obsolete part cross reference hub is where that conversation starts.