INA2141U
Product Specifications
INA2141U
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA2141U from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA2141U: the plain grade of the dual gain of ten or one hundred front end, in a forty piece tube
INA2141U is the dual three op amp instrumentation amplifier with a fixed gain of 10 or 100, in the sixteen pin SOIC body and a forty piece tube. At a gain of 100 the offset is 20 microvolts typical and 50 maximum, the rejection is 117 dB minimum and 125 typical, and the bandwidth is 200 kilohertz.
The gain is chosen by the pin connection rather than by a resistor, which is what a multi channel scanner with a fixed full scale wants. The tube is the only carrier this body has for the plain grade, and the A grade is published in the same tube and on a 1000 piece reel. Both grades share the 40 volt input protection and the plus and minus 2.25 to plus and minus 18 volt supply.
INA2141U as the vendor document publishes it
| Channels | 2 |
| Gain | 10 or 100 V/V, set by the pin connection |
| Supply | plus or minus 2.25 to plus or minus 18 volts |
| Offset at a gain of 100 | 20 microvolts typical, 50 maximum plain, 125 maximum A code |
| Offset drift | 0.2 typical with 0.5 maximum plain, 1.5 maximum A code microvolts per degree |
| Input bias current | 2 typical, 5 maximum, 10 over temperature nanoamps |
| Rejection at a gain of 100 | 117 minimum, 125 typical plain, 110 minimum A code |
| Rejection at a gain of 10 | 97 minimum, 106 typical plain, 93 minimum A code |
| Gain error at a gain of 100 | 0.03 typical with 0.075 maximum, 0.15 over temperature per cent |
| Gain error at a gain of 10 | 0.01 typical with 0.05 maximum per cent |
| Gain drift | 2 parts per million per degree typical, 10 maximum |
| Voltage noise | 10 nanovolts at 10 hertz, 8 at 1 kilohertz, at a gain of 100 |
| Bandwidth and slew | 200 kilohertz at a gain of 100, 1 megahertz at 10, 4 volts per microsecond |
| Settling time | 9 microseconds to 0.01 per cent at a gain of 100 |
| Safe input | plus and minus 40 volts |
| Temperature range | minus 40 to plus 85 degrees specified, minus 40 to plus 125 operating |
| Vendor status | active, forty piece tube |
| Catalogue code | INA2141U |
| Carrier | tube of 40 |
| Lead finish | printed as a call to the vendor on this row |
| Moisture level | level 3, 260 degrees, 168 hour floor life |
Two gains, ten and one hundred, set by two pins
INA2141U is a dual three op amp instrumentation amplifier with a gain of 10 or a gain of 100, chosen by which pin the signal is returned to rather than by an external resistor. Both values are trimmed inside the package, so the gain error at 10 is 0.01 per cent typical and 0.05 maximum, and at 100 it is 0.03 typical and 0.075 maximum, with 0.15 as the worst case over temperature.
The fixed pair is what a multi channel board wants: eight channels of a data acquisition card can share one part number and one calibration table, and there is no gain resistor to place, match or drift. The cost is that the gain cannot be changed later, and a channel that needs 50 or 200 has to move to the resistor set family or accept a different full scale.
Twenty microvolts at a gain of one hundred
The offset of INA2141U is quoted at a gain of 100, where it is 20 microvolts typical and 50 maximum on the plain code and 125 maximum on the A code, referred to the input. The drift is 0.2 microvolts per degree typical with 0.5 maximum on the plain code and 1.5 on the A code, and the long term stability is not published as a separate row on this document.
At a gain of 100 the input referred offset dominates and the output referred offset is the input figure plus the 100 times the output stage term, which the table folds into the same row. On a 10 millivolt full scale signal that is 0.2 per cent on the plain code and 1.25 per cent on the A code, so the grade is a calibration decision again. The bias current of 2 nanoamps typical and 5 maximum into a 1 kilo-ohm bridge arm adds 5 microvolts, which is a quarter of the offset.
One hundred and seventeen decibels at a gain of one hundred
The common mode rejection of INA2141U is 117 dB minimum and 125 dB typical at a gain of 100 on the plain code, and 110 minimum with 120 typical on the A code. At a gain of 10 the same rows read 97 and 106 against 93 and 100. The common mode window is two volts inside the negative rail and 1.4 volts inside the positive one.
The rejection rises with gain because the input stage carries the full common mode and the output stage only sees the difference, which is the property that makes a three op amp part useful on a 24 volt loop. At 117 dB, 20 volts of common mode becomes 28 microvolts at the input, which is the same order as the offset and therefore invisible in the budget. At 97 dB on the gain of 10 connection the same 20 volts becomes 280 microvolts, which is a real error on a 100 millivolt signal.
Plus and minus forty volts of protection on a plus and minus two and a quarter volt supply
INA2141U runs from plus and minus 2.25 to plus and minus 18 volts, protects its inputs to plus and minus 40 volts, and has a differential input impedance of 10 gigaohms in parallel with 9 picofarads and a common mode impedance of 10 gigaohms in parallel with 9 picofarads. The output swings to within 1.4 volts of each rail at light load and within 0.9 volts into 10 kilo-ohms, and it is stable into 1000 picofarads.
The document pages that would carry a quiescent current limit row instead carry a typical curve, so the current is not a guaranteed number on this part and a budget that depends on it should measure a sample rather than read the feature list. The short circuit current is plus 6 and minus 15 milliamps, which is an asymmetric output stage and worth knowing when the part drives a capacitive load through a cable.
Eight nanovolts, and a bandwidth of two hundred kilohertz at a gain of one hundred
The voltage noise of INA2141U is 10 nanovolts per root hertz at 10 hertz and 8 nanovolts at 100 hertz and 1 kilohertz at a gain of 100, rising to 22, 13 and 12 nanovolts at a gain of 10, with 0.2 and 0.6 microvolts peak to peak from 0.1 to 10 hertz. The current noise is 0.9 picoamps per root hertz at 10 hertz and 0.3 at 1 kilohertz.
The bandwidth is 200 kilohertz at a gain of 100 and 1 megahertz at a gain of 10, with a slew rate of 4 volts per microsecond and a settling time of 9 microseconds to 0.01 per cent at a gain of 100. That combination is what a multiplexed 16 bit scanner needs: the part settles inside a 10 microsecond window, so the conversion time is set by the converter rather than by the amplifier, and the 8 nanovolts are 4 microvolts over a 250 kilohertz noise band.
Where a fixed gain of ten or one hundred belongs
INA2141U belongs in a thermocouple or RTD scanner, a bridge front end with a fixed full scale, a 4 to 20 milliamp receiver with a fixed sense resistor, and a multi channel analog input module where every channel has the same range. The 117 dB of rejection and the 40 volt protection are what a 24 volt loop needs, and the 200 kilohertz bandwidth is what a scanner needs to keep its per channel time short.
It does not belong where the full scale changes, because the gain is fixed. It does not belong on a 3.3 volt rail, because the supply floor is 4.5 volts total. It does not belong where the quiescent current has to be a guaranteed number, because the document only publishes a typical curve. And it does not belong on a high impedance source above 100 kilo-ohms without a buffer. Our amplifier cross reference page covers the resistor set parts for variable gain, and the traceability report page covers what travels with the tube and the reel.
The gain connection is a board decision and the grade is a calibration decision. Our amplifier cross reference page covers the graded pair, and the traceability report page covers the tube documentation.
Can the gain be changed at run time? No. It is 10 or 100 by wiring, and both values are trimmed inside the package.
Is the quiescent current a guaranteed number? No. The document publishes it as a typical curve rather than as a limit row, so a budget that depends on it should measure a sample.