INA199C3QDCKRQ1
Product Specifications
INA199C3QDCKRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA199C3QDCKRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA199C3QDCKRQ1: 200 V/V automotive monitor with the tighter C grade
The INA199C3QDCKRQ1 is the 200 V/V member of the INA199-Q1 family with the C accuracy grade, in a 6 pin SC70 body. It reads a shunt between 0.1 V below ground and 26 V above it, runs from 2.7 V to 26 V, and multiplies the shunt drop by 200 so that a 10 mV full scale sense becomes 2 V at the output. The C letter is the commercially important part of the string: gain error over temperature is limited to 1 percent instead of the 1.5 percent of the A and B rows, while offset stays at 150 uV maximum with 0.5 uV per degree of drift.
Grade 1 under AEC-Q100 means the part is specified from minus 40 C to plus 125 C ambient, and the qualified family carries functional safety documentation. Compared with the industrial INA199 the automotive row narrows the common mode floor from 0.3 V below ground to 0.1 V below ground, which matters in a circuit that expects a low side shunt to swing below the local ground during a reverse current event. The bandwidth at gain 200 is 14 kHz, the lowest of the three gains and still far above the loop bandwidth of a battery charger.
Key data for the INA199C3QDCKRQ1
| Gain | 200 V/V, the highest of the three series options, with 50 and 100 in the same body |
| Input | Common mode minus 0.1 V to plus 26 V, bidirectional, independent of the supply |
| Accuracy | C grade gain error 1 percent maximum over temperature, offset 150 uV maximum, drift 0.5 uV per degree |
| Bandwidth | 14 kHz at gain 200 with a 10 pF load, 30 kHz at gain 100 and 80 kHz at gain 50 |
| Supply | 2.7 V to 26 V, 100 uA maximum quiescent current, no enable pin on the SC70 body |
| Qualification | AEC-Q100 grade 1, minus 40 C to 125 C, functional safety documentation available |
Body, marking and reel data
| Body | DCK, SC70 6 pin, 2.00 mm by 1.25 mm, the only body offered on the Q1 series |
| Reel | 3000 pieces on a large reel, no small reel option printed for this string |
| Finish | NIPDAU, moisture level 2 at 260 C with a one year floor life |
| Marking | 17C on the C3 automotive row, three characters that carry neither gain nor grade |
| Temperature | Minus 40 C to 125 C ambient, grade 1, not a junction only rating |
When 200 V/V is the right gain on a vehicle rail
On a 12 V automotive rail the currents that matter are small in standby and large under load, and a fuel gauge or a body controller usually cares about the small end. At gain 200 a 5 milliohm shunt produces 1 V per amp, so a 200 mA standby load reads 200 mV, which is far above the 150 uV offset and comfortably inside a 3.3 V converter input. The same shunt at 20 A would want 20 V at the output, so the part cannot cover both ends and is not asked to: the high current path is protected by a fuse and a comparator, not measured by this amplifier.
The second decision is the reference. The REF pin sets the zero current output level, so a bidirectional rail with a 1.65 V reference can read plus and minus current around that point, while a ground referenced REF turns the part into a charge only monitor. Automotive projects that change this late tend to discover it as a one sided reading. Where a customer is qualifying a second source, our amplifier cross reference lists the series by gain, grade and body, and the drop in verification note records the electrical and mechanical checks we run before release.
Buyer questions on the INA199C3QDCKRQ1
Does the Q1 string share the industrial part's land pattern? Yes, both are SC70 6 pin. The difference is the qualification and the narrowed common mode floor, so the board does not change and the recalibration is minimal.
What is the difference between the A, B and C rows? The C rows tighten gain error over temperature to 1 percent. The A and B rows allow 1.5 percent. Offset, drift and bandwidth are the same, so the grade is bought for the error budget and not for the speed.
Can the part be left powered in a parked vehicle? At 100 uA maximum it is a small standing load, but it is not zero. A module with a hard standby requirement should switch the monitor supply rather than leave it on the battery rail.
Availability and ordering notes
The C3 Q1 string is active at 3000 pieces on a large reel with NIPDAU and moisture level 2, marking 17C. The automotive series is documented separately from the industrial INA199 sheet, so a Q1 string is verified against SBOS781 and its own addendum. Where a customer needs prototypes, the only route on this string is a broken reel or a repack, because the addendum prints no small reel row. We state that in the quote rather than after the order, and the moisture level and date code travel on the date code management note.