INA190A5QDDFRQ1
Product Specifications
INA190A5QDDFRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA190A5QDDFRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA190A5QDDFRQ1: 500 V/V automotive shunt monitor that still reads microamps
The INA190A5QDDFRQ1 is the highest gain member of the INA190-Q1 family, a bidirectional current sense amplifier in a SOT-23-8 body with an enable pin. The A5 row multiplies the shunt drop by 500, which turns a 9 mV full scale input into a 4.5 V output, so a 1 ohm shunt covers roughly 9 mA and a 100 ohm shunt covers roughly 90 uA without any second stage. The input stage draws 500 pA of bias current, and that is the number that decides whether a large shunt is usable at all: at 1 uA through 100 ohm the shunt drop is 100 uV, and a bias current of a few nanoamps would already be a measurable fraction of it.
Everything else in the part is built around a battery line. The common mode window runs from minus 0.2 V to plus 40 V independent of the 1.7 V to 5.5 V supply, the input pins survive 42 V, and the quiescent current is 50 uA typical with 100 nA in shutdown. Zero drift chopping holds offset to 15 uV maximum and offset drift to 80 nV per degree, which is what allows a 100 uV signal to mean something across a cabin temperature swing. The device is AEC-Q100 grade 1 qualified, so the published rows are specified from minus 40 C to plus 125 C ambient.
Key data for the INA190A5QDDFRQ1
| Gain | 500 V/V fixed, one of five options from 25 to 500, trimmed inside the package with 7 ppm per degree drift |
| Input | Common mode minus 0.2 V to plus 40 V, 42 V survivable, 500 pA typical bias current, bidirectional |
| Accuracy | Offset 15 uV maximum, offset drift 80 nV per degree, gain error 0.2 percent on the A1 row and its own figure on A5 |
| Supply | 1.7 V to 5.5 V single supply, 50 uA typical quiescent, 100 nA maximum in shutdown, enable pin fitted |
| Bandwidth | 27 kHz at gain 500 with a 10 pF load, falling from 45 kHz on the A1 row as gain rises |
| Output | Rail to rail voltage output, swing to within a few tens of millivolts of either rail at light load |
Body, marking and reel data
| Body | DDF, SOT-23 thin 8 pin, 1.60 mm by 2.90 mm, the only body that carries the enable pin alongside the 6 pin SC70 |
| Reel | 3000 pieces on a large reel for the Q1 string, the same packing as the industrial INA190A5IDDFR |
| Finish | NIPDAU, moisture level 1 at 260 C, so no floor life clock and no bake before reflow |
| Marking | 2C5W on the automotive A5 row, a four character code that does not spell the part number |
| Temperature | Minus 40 C to 125 C ambient, AEC-Q100 grade 1, functional safety documentation available |
Where a 500 V/V front end earns its place
The application list in the data sheet is a list of modules that have to know their own standby current: body control, telematics, emergency call, battery management and the head unit. In a parked car the interesting current is not the 20 A cranking event, it is the 200 uA that a sleeping module should draw and the 3 mA it draws when a regulator has failed to shut down. A 20 V/V amplifier cannot see that without a shunt large enough to drop real voltage in the load path. A 500 V/V amplifier can, because the same 10 mV of full scale now corresponds to a shunt of tens of ohms rather than a fraction of an ohm.
Two practical limits follow. First, the output swing sets the maximum shunt drop: on a 3.3 V supply the output reaches about 3.2 V, so the input window is 6.4 mV, and on a 5 V supply it is about 9.8 mV. A larger shunt than that simply saturates the output on the smallest current the system cares about. Second, the 42 V survivable input covers a jump start on a 12 V rail but not an unclamped load dump, so the front end still needs its clamp and its series resistor. Where a production line is moving to this part from a lower gain device, our amplifier cross reference lists the current sense families by gain, common mode and body, and the pin to pin cross reference note records which of them share a land pattern.
Buyer questions on the INA190A5QDDFRQ1
Is the A5 gain available at 1.8 V supply? Yes, the supply floor is 1.7 V, but the output swing then limits the usable shunt drop to roughly 1.8 mV at gain 500. At that point the offset figure starts to matter, so the A1 or A2 row is usually the better choice.
Why does the enable pin matter on a current monitor? Because a monitor that cannot be turned off becomes part of the standby current it is measuring. The shutdown current is 100 nA maximum, and the enable pin is only brought out on the DDF and RSW bodies, not on the 6 pin SC70.
Can the DDF and the SC70 rows be mixed on one board? No. They are different footprints with different pin counts. The die is the same and the gain options match, so the choice is made by the land pattern and not by the electrical specification.
Availability and ordering notes
The Q1 string is active in the current addendum at 3000 pieces on a large reel with NIPDAU and moisture level 1, marking 2C5W. Two things are worth writing down before a purchase order goes out. The four character marking does not identify the gain, so a bag without its reel label cannot be sorted by eye. And the automotive addendum and the industrial addendum are separate documents: a string carrying the Q1 suffix cannot be verified against the industrial sheet, and the reverse is also true. We read the gain letter, the body and the qualification level off the reel label before quoting, and the date code and moisture history travel with the shipment on the date code management note.