Contact Us

INA186A5IDCKR

Brand: Texas Instruments
Texas Instruments INA186A5IDCKR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

INA186A5IDCKR — Power Management & Signal Chain | Superb Automation

INA186A5IDCKR

Texas Instruments — Power Management & Signal Chain

Product Overview

The INA186A5IDCKR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

INA186A5IDCKR: gain of 500 for a microamp measurement in a six pin body

The A5 member of the INA186 family has a fixed gain of 500 V/V, the highest in the family, in the six pin SC70 body. With 3 microvolts of typical offset, 50 microvolts maximum and 0.5 nA of input bias current, the part is built for the bottom of the current range rather than the top: a 10 ohm shunt carrying 1 mA develops 10 mV, which becomes 5 V at the output, so a milliamp level current fills a converter range that a gain of 50 would barely touch. Common mode range is 0.1 V to 40 V and the supply is 1.7 V to 5.5 V, so the part can measure a small current on a high rail without a divider.

Bandwidth at this gain is 35 kHz, the lowest in the family, and the enable pin gives a shutdown state that drops the supply current to nanoamps while the output goes high impedance. Settling is 30 microseconds to within 1 per cent of a step, so a channel that is enabled, read and disabled in a slow scan cycle has time to settle between readings. Gain error is 1 per cent maximum over temperature, and the reference voltage rejection is specified so a reference that moves does not appear at the output as a current reading.

Key data for the INA186A5IDCKR

Gain500 V/V fixed, the highest member, so 10 mV of shunt drop becomes 5 V of output
Offset3 microvolts typical and 50 microvolts maximum, drift 0.05 microvolts per degree typical
Bias0.5 nA typical input bias current, which is what allows a shunt of tens of ohms on a microamp range
Common mode0.1 V to 40 V, rejection 120 dB minimum and 150 dB typical, independent of the supply
Bandwidth35 kHz at this gain, 30 microseconds settling to 1 per cent, 75 nV per root hertz of input noise
EnableA shutdown state with nanoamp supply current and a high impedance output between readings

Body, marking and reel data

BodyDCK, SC70 6 pin, 2 mm by 1.25 mm, 3000 pieces on a large reel, 210 mm carrier
Marking1IM on the A5 row of the DCK body, distinct from the codes used by the other gain members
FinishSNAGCU or NIPDAU depending on the row, moisture level 2 with a one year floor life
GradeAmbient minus 40 C to 125 C, the industrial rows, with the automotive string separately documented

Where a gain of 500 is the right choice

A gain of 500 exists for the case where the current is small and the shunt cannot be large, either because the voltage drop would disturb the load or because the resistor would dissipate too much. A battery powered sensor that sleeps at 20 microamps through a 100 ohm shunt develops 2 mV, which at a gain of 500 is 1 V and at a gain of 50 is 100 mV, close to the offset. The higher gain buys resolution in exchange for bandwidth, and a sleep current measurement does not need speed.

The same reasoning applies to a leakage test, a photodiode bias current, or a solenoid holding current that has to be distinguished from an inrush. Where a customer needs both a wide range and a microamp range on one board, the family is used twice with different gains, which is cheaper than one autoranging channel. Our power management cross reference lists the five gains by body, and the medical device component page covers the low current monitoring used in portable patient equipment.

Buyer questions on the INA186A5IDCKR

Does a gain of 500 clip easily? Yes, above about 10 mV of shunt drop on a 5 V supply. The full scale has to be chosen so the largest current expected stays below the output swing, which is why the shunt value matters more than the gain.

How much current does the enable pin save? The shutdown state draws nanoamps and the output goes high impedance, so a channel scanned once a second spends almost all of its time in that state. The enabled current is tens of microamps.

Is the offset still acceptable at this gain? The 3 microvolt typical offset becomes 1.5 mV at the output, so a 1 V full scale reading carries 0.15 per cent of typical offset. The 50 microvolt maximum becomes 25 mV, which is 2.5 per cent, so a production unit is calibrated at test.

Availability and ordering notes

The SC70 body at 3000 pieces is the production packing and the same die is available in the thin SOT-23 with eight pins where a larger pad geometry is easier to place. Where the board is already built around the SC70 footprint, the A5 gain can be swapped for another member of the family without a change to the copper. We quote the marking with the code and confirm the gain at goods inward, and the record travels with the shipment through our date code management process.